Equipment and Calibration History
Page: 1 2 3 4 5 6 7 8 [9] 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65Ser No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
eosFD FD20180067 | 2022-07-14 | Lab none | Installed | Bouldin Corn Forced Diffusion C | Installed in the corn at BC. It's in the same location from where it was removed, one row west of the zcam. I connected to the FD chamber to confirm that it was running. |
NL115 13056 | 2022-07-14 | Lab none | Installed | Bouldin Corn Interface NL115 | Installed on the BC met CR1000 to replace sn 6761, which was brought back to the lab for testing. |
NL115 6761 | 2022-07-14 | Bouldin Corn Interface NL115 | Removed | Lab none | Removed from BC and brought back to the lab for testing. The bottom 1/2-1/3 of phenocam photos is gray. Could be an interface or a card problem. It was replaced by sn 13056. |
HFP01 003072 | 2022-07-14 | Bouldin Alfalfa-ADEX Heat Flux Plate Bouncer A | Removed | Lab none | Removed from the BA Bouncer tower because the cable was cut. I will repair it in the lab before we install it again. |
WM 1590 153805 | 2022-07-31 | Lab none | Tested | Lab none | Tested the sonic and its cable in the lab with Joe's help over e-mail. Both tested fine. I mated the sonic cable with an Eosense cable and used the conductivity setting on the voltmeter to find the 4 eosense wires that corresponded to outputs 1-4. At rest (while I was standing still next to the sonic), the voltages were around +/- 8mV. I then used a fan to test U, V, W. The voltages went up to around 150mV. Placing the fan on the opposite side of the sonic produced about the same magnitude voltage with the opposite sign. SOS (output 4) was around 1.7V and didn't change much with the fan, as expected. I wired the Eosense cable to a CR1000 with a NL115 and ran it overnight, storing 30min and 20Hz data on an 8gb card. The data the next morning seemed reasonable. SOS had the same pattern as PanelT. Sonic pin -> Licor color -> Eosense cable 8 (Output 1) -> white -> brown 14 (Output 2) -> green -> white 9 (Output 3) -> grey -> pink 15 (Output 4) -> blue -> black 10 (Analog G) -> red -> grey 16 (Analog G) -> pink -> yellow 17 (Analog G) -> yellow/brown -> blue |
WM 1590 153805 | 2022-08-01 | Lab none | Installed | Mayberry Anemometer | Installed on MB after testing in the lab. Sonic heading = 10 deg true N. |
LI-7700 TG1-0223 | 2022-06-08 | Lab none | Installed | Mayberry Gas Analyzer CH4 | Installed at MB after attaching a new fuse holder and fuse. This sensor was calibrated in the lab yesterday. |
WM 1590 153805 | 2022-07-26 | Mayberry Anemometer | Removed | Lab none | Removed from MB tower for inspection back at the lab. The sonic heading was 7 deg true N before removal. |
LI-7700 TG1-0421 | 2022-07-15 | Lab none | Loaned | Loaned none | Installed on the BWW urban tower and updated the GHG columns. I also connected the HMP back to the 7700 auxiliary input. However, I couldn't remember the correct coefficients for the HMP. I tried the same multiplier and offset we use for CRBasic, but that didn't produce reasonable data. I e-mailed Joe for help and he fixed it the following day. This sensor still needs a wash box and wash power cable. These will have to come from BA after our next visit. The current wash tubing is a spliced one, so I could also replace that with new black tubing. |
LI-6400 PSC-0785 | 2019-06-03 | Lab none | Loaned | Loaned none | Loaned to Yvonne Socolar. Other material loaned: -10 cartridges -Box of spare parts -Two 12V Battery |
LI-6400 PSC-0785 | 2022-07-20 | Lab none | Loaned | Loaned none | Loaned to Rizwan Rasheed from Ellen Simms' lab for the summer. Other items loaned: 2 9Ah batteries and a 12V power cord. They had originally borrowed Dave Ackerly's 6400 but we couldn't get it to turn on (display remained off). |
LI-7700 TG1-0421 | 2022-06-01 | Factory | Calibration | Factory | Calibration Location: Factory Last calibration: 2021-11-30 RSSI=0%, Optical RH=0% Ambient P=0kPa, Tair=0C 0 at 0psi, 0 0 at 0 CH4 Zero Offset: 10.1875ppm CH4 Span Offset: .000103546ppm Notes: Calibrated at Licor factory after replacing fuse holder and fuse. Not sure of the offset units (but probably not in ppm?) |
LI-7700 TG1-0421 | 2022-07-05 | Factory none | Returned | Lab none | Received back in the lab after repair and calibration at Licor. They replaced the fuse and fuse holder and calibrated the instrument. |
LI-7700 TG1-0421 | 2022-04-28 | Lab none | Shipped | Factory none | Sent back to Licor for inspection/repair around this date. |
eosFD FD20180067 | 2022-07-11 | Lab none | Tested | Lab none | Plugged in and tested in the lab with another eosense cable. The chamber seems to be fine and the clock was still accurate, so I downloaded data from 2022-05-11 to 2022-06-08. I also ran a performance check which looked fine. I did not reset the reference.
Average Flux: -0.2, 0.05 STDEV Average ATM: 687.6ppm, 29.6C Average Soil: 677.7ppm, 29.8C |
eosFD FD20180067 | 2022-06-08 | Bouldin Corn Forced Diffusion C | Removed | Lab none | Removed from field and brought back to the lab because even though the pump sounds like it's working, we haven't been able to connect to it for the past month |
NL115 6761 | 2022-06-09 | Lab none | Installed | Bouldin Corn Interface NL115 | Installed on met CR1000 at BC and connected to Stardot phenocam |
eosFD FD20180067 | 2022-02-17 | Lab none | Installed | Bouldin Corn Forced Diffusion C | Installed at BC under the tower |
BB-Fab BB-HS | 2022-04-20 | Hill Slough Battery Bank | Maintenance | Hill Slough Battery Bank | There has been some power losses a couple weeks ago but okay for the last two weeks. All the screw terminals seemed tight. One of the battery terminals had some corrosion - all the terminals should be cleaned and sealed before winter. |
BB-Fab BB-HS | 2021-03-11 | Sherman Wetland-Temp1 Battery Bank | Installed | Hill Slough Battery Bank | We put the battery box from SW on the west side of the platform and installed the five group 31 flooded batteries from the SW temporary tower. The solar controller sn 11400080 and breakers from the SW temporary site were also installed in the battery box. The wiring is not optimal and should be cleaned up. Also because the drill battery died we could not mount the solar controller or bolt the battery box to the platform. |
NR01 1454 | 2011-02-03 | Factory none | Calibration | Factory none | Initial factory calibration: Pyranometer Up (mn SR01 sn 1957) 15.3uV/Wm-2, Pyranometer Down (mn SR01 sn 1958) 13.6uV/Wm-2, Pyrgeometer Up (mn IR01 sn 1946) 9.0uV/Wm-2. Pyrgeometer Down (mn IR01 sn 1947) 9.4uV/Wm-2. |
LI-7700 TG1-0155 | 2022-06-09 | West Pond | Calibration | West Pond | Calibration Location: West Pond Last calibration: 2021-12-06 RSSI=90%, Optical RH=3% Ambient P=101.1kPa, Tair=30.1C Zero Air at 400psi, AMP CA04119 4.2238 at 1550 CH4 Zero Offset: .016ppm CH4 Span Offset: .0028ppm Notes: Hot but relatively still at this site |
LI-7700 TG1-0211 | 2022-06-08 | Hill Slough | Calibration | Hill Slough | Calibration Location: Hill Slough Last calibration: 2021-12-01 RSSI=73%, Optical RH=21% Ambient P=100.7kPa, Tair=24.0C Zero Air at 550psi, AMP CA04119 4.2238 at 1525 CH4 Zero Offset: -.002ppm CH4 Span Offset: .0008ppm Notes: Very windy day of course. Did not change drierite or flush headspace with zero air. Changed the top/bottom heater to start at 18:00 instead of at 16:00 for summertime. |
LI-7700 TG1-0357 | 2022-06-08 | Bouldin Corn | Calibration | Bouldin Corn | Calibration Location: Bouldin Corn Last calibration: 2021-12-01 RSSI=77%, Optical RH=16% Ambient P=101kPa, Tair=28C Zero Air at 600psi, AMP CA04119 4.2238 at 1600 CH4 Zero Offset: -.074ppm CH4 Span Offset: .0078ppm Notes: Extra windy day of course. Did not change drierite or flush headspace with zero air. |
LI-7700 TG1-0424 | 2022-06-09 | Gilbert Tract | Calibration | Gilbert Tract | Calibration Location: Gilbert Tract Last calibration: 2021-11-30 RSSI=74%, Optical RH=16% Ambient P=101kPa, Tair=21.6C Zero Air at 450psi, AMP CA04119 4.2238 at 1450 CH4 Zero Offset: -.01ppm CH4 Span Offset: .0698ppm Notes: Breezy day. Did not change drierite or flush headspace with zero air. |
LI-7700 TG1-0423 | 2022-06-09 | East End | Calibration | East End | Calibration Location: East End Last calibration: 2021-12-01 RSSI=70%, Optical RH=17% Ambient P=101kPa, Tair=29.5C Zero Air at 350psi, AMP CA04119 4.2238 at 1550 CH4 Zero Offset: .015ppm CH4 Span Offset: -.0098ppm Notes: Hot day, some breeze. Did not change drierite or flush headspace with zero air. |
TS01 TS01-002 | 2022-06-07 | Tonzi | Removed | Lab none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
SI-121 1624 | 2022-06-07 | Tonzi Infrared Temperature Ref Panel B | Removed | Lab none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
SI-131 7638 | 2022-06-07 | Tonzi | Removed | Lab none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
SI-131 7385 | 2022-06-07 | Tonzi Infrared Temperature Grass B | Removed | Lab none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
CR10X 47772 | 2022-06-07 | Tonzi | Removed | Lab none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
CR23X 2143 | 2022-06-07 | Tonzi none | Removed | Lab none | Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed |
LI-7700 TG1-0223 | 2022-06-07 | Lab none | Calibration | Lab none | Calibration Location: Lab
Last calibration: 2021-12-03 RSSI=76%, Optical RH=29% Ambient P=100.0kPa, Tair=21.7C Zero Air at 625psi, AMP CA04119 4.2238 at 1600 CH4 Zero Offset: -.037ppm CH4 Span Offset: .0392ppm Notes: Before this calibration, I replaced fuse and fuse holder. I added some grease to the large o-ring around the base (Licor grease in the small plastic container) before reassembling everything. I followed Joe's advice to use longer helper screws help get the bottom to seat all the way in, and then replace those "helper" screws with the original screws with o-rings. During calibration for the span, I realized at 16:10 that the top heater had been on since 16:00. Probably the zero was calibrated while the heater was on. The span seemed stable from 16:12-16:18 and I don't think turning the heater off really affected it. I spanned the sensor at 16:18. After calibration, I pumped zero air into the headspace until optics RH=10%. I swapped out the old purple desiccant for a bottle of fresh blue desiccant. I added a bit of grease to the desiccant plug as well. |
NL115 13056 | 2022-06-06 | Lab none | Tested | Lab none | I tested this CFM interface on the CR1000 in the lab. It didn't seem to have any trouble. Worked with both CF cards that I had trouble with in the field. I could ping the ethernet port. Maybe try updating the CR1000 OS in the field. |
CS655 17129 | 2022-05-27 | Bouldin Corn Soil Moisture Probe A | Moved | Bouldin Corn Soil Moisture Probe A | Moved from under the tower in to the field after planting northwest of the tower. The tower was moved about 2m west to the edge of the field |
CS655 17133 | 2022-05-27 | Bouldin Corn Soil Moisture Probe C | Moved | Bouldin Corn Soil Moisture Probe C | Moved from under the tower in to the field after planting west of the tower. The tower was moved about 2m west to the edge of the field |
CS655 17128 | 2022-05-27 | Bouldin Corn Soil Moisture Probe B | Moved | Bouldin Corn Soil Moisture Probe B | Moved from under the tower in to the field after planting southwest of the tower. The tower was moved about 2m west to the edge of the field |
NL115 13056 | 2022-05-27 | Bouldin Corn Interface NL115 | Removed | Lab none | I could not get this card reader to work with either of two CF cards. Removed for testing in the lab. |
SoilVUE10 2677 | 2022-05-26 | Lab none | Installed | Vaira Soil Moisture Probe I Profile | Installed 5.3m at heading 220deg from the met box about a meter outside the fence near the gate. |
SoilVUE10 2679 | 2022-05-26 | Lab none | Installed | Vaira Soil Moisture Probe H Profile | Installed 7.7m at heading 26deg from the met box near the solar panels and the old Moisture Point probe location |
LI-7700 TG1-0223 | 2022-05-27 | Mayberry Gas Analyzer CH4 | Removed | Lab none | Removed from Mayberry because water got inside and rotted out the fuse on the bottom of the can. Same as WP a few weeks ago. |
SoilVUE10 2690 | 2022-05-26 | Lab none | Installed | Vaira Soil Moisture Probe F Profile | Installed at 5.4m at heading 345deg from the met box about halfway between the eddy tower and radiation tower |
RPI0W RPI0W-002 | 2021-08-17 | Bouldin Corn | Removed | Lab none | Removed from the BC field and brought back to the lab since the canopy has finished developing for this year |
RPI0W RPI0W-001 | 2021-08-17 | Bouldin Corn | Removed | Lab none | Removed from the BC field and brought back to the lab since the canopy has finished developing for this year |
PS-30 19391162 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Solar Controller Edge | Installed on the Edge tower for the advection experiment at BA |
PS-15 03220377 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Solar Controller Bouncer | Installed on the Bouncer tower for the advection experiment at BA |
SQ75 024398E-1-26-04-99974 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Solar Panel Edge B | Installed about 10m north of the Edge tower at -10cm for the advection experiment |
SP75 020854E-6-03-02-06862 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Solar Panel Edge A | Installed about 10m north of the Edge tower at -10cm for the advection experiment |
SQ75 020854E-6-03-02-06832 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Solar Panel Bouncer B | Installed about 10m south of the Bouncer tower for the advection experiment |
SQ75 020854E-6-03-02-06825 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Solar Panel Bouncer A | Installed about 10m south of the Bouncer tower for the advection experiment |
ML3 M003371 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Soil Moisture Probe Bouncer B | Installed about 2m north of the Edge tower at -10cm for the advection experiment |
CS655 17130 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Soil Moisture Probe Edge A | Installed about 2m north of the Edge tower at -10cm for the advection experiment |
ML3 M001972 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Soil Moisture Probe Edge B | Installed about 2m south of the Bouncer tower at -10cm for the advection experiment |
CS655 17131 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Soil Moisture Probe Bouncer A | Installed about 2m south of the Bouncer tower at -10cm for the advection experiment |
HP-127-1.0-1.3-71P PC4 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Heat Flux Plate Edge C | Installed about 2m north of the Edge tower at -10cm for the advection experiment |
HP-127-1.0-1.3-71P PC3 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Heat Flux Plate Edge B | Installed about 2m north of the Edge tower at -10cm for the advection experiment |
HFP01 003073 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Heat Flux Plate Edge A | Installed about 2m north of the Edge tower at -10cm for the advection experiment |
HP-127-1.0-1.3-71P PC2 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Heat Flux Plate Bouncer C | Installed about 2m south of the Bouncer tower at -10cm for the advection experiment |
HP-127-1.0-1.3-71P PC1 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Heat Flux Plate Bouncer B | Installed about 2m south of the Bouncer tower at -10cm for the advection experiment |
HFP01 003072 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Heat Flux Plate Bouncer A | Installed about 2m south of the Bouncer tower at -10cm for the advection experiment |
CR23X 2303 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Data Logger Edge Met | Installed on the Edge tower to collect 30min averages from soil senors for the advection experiment at BA |
CR6 2115 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Data Logger Edge Flux | Installed on the Edge tower to collect 20Hz data from the lower sonic and 10sec data from the two RH/Temp sensors for the advection experiment at BA |
CR23X 2300 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Data Logger Bouncer Met | Installed on the Bouncer tower to collect 30min averages from soil senors for the advection experiment at BA |
CR6 2114 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Data Logger Bouncer Flux | Installed on the Bouncer tower to collect 20Hz data from the lower sonic and 10sec data from the two RH/Temp sensors for the advection experiment at BA |
CR1000 23865 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Data Logger Main Flux | Installed on the main tower to collect 20Hz data from the two additional sonics for the advection experiment at BA |
LI-7550 AIU-0674 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Interface Edge LI-7550 | Installed on the Edge tower for the advection experiment at BA |
LI-7550 AIU-2312 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Interface Bouncer LI-7550 | Installed on the Bouncer tower for the advection experiment at BA |
LI-7500A 0042 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Gas Analyzer Edge CO2/H2O | Installed on top of the Edge tower at 3.96m alg for the advection experiment at BA |
LI-7500RS 75H-0128 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Gas Analyzer Bouncer CO2/H2O | Installed on top of the Bouncer tower at 3.96m alg for the advection experiment at BA |
NR-LITE 990350 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Net Radiometer Edge | Installed on top of the Edge tower at 334m alg for the advection experiment at BA |
NR-LITE 990353 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Net Radiometer Bouncer | Installed on top of the Bouncer tower at 3.34m alg for the advection experiment at BA |
HMP45AC T1020004 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX RH & Temp Egde Lower | Installed on the main post at the Edge tower at 2.42m alg for the advection experiment at BA |
HMP45AC D4420028 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX RH & Temp Edge Upper | Installed on top of the Edge tower at 3.96m alg for the advection experiment at BA |
HMP155 T2930114 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX RH & Temp Bouncer Lower | Installed on the main post at the Bouncer tower at 2.42m alg for the advection experiment at BA |
HMP45AC D4420029 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX RH & Temp Bouncer Upper | Installed on top of the Bouncer tower at 3.96m alg for the advection experiment at BA |
HygroVUE10 E3514 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX RH & Temp Main Lower | Installed on the existing eddy post at the main tower at 2.42m alg for the advection experiment at BA |
HygroVUE10 E3452 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX RH & Temp Main Upper | Installed on a new post at the main tower at 6.08m alg for the advection experiment at BA |
WM 1590 152603 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Anemometer Egde Lower | Installed on a cross arm at the Edge tower at 2.42m alg for the advection experiment at BA |
WM 1590 152601 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Anemometer Edge Upper | Installed on top of the Edge tower at 3.96m alg for the advection experiment at BA |
WM 1590 153804 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Anemometer Bouncer Lower | Installed on a cross arm at the Bouncer tower at 2.42m alg for the advection experiment at BA |
WM 1590 152606 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Anemometer Bouncer Upper | Installed on top of the Bouncer tower at 3.96m alg for the advection experiment at BA |
WM 1590 152608 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Anemometer Main Lower | Installed on a new cross arm at the main tower at 2.42m alg for the advection experiment at BA |
WM 1590 152605 | 2022-04-25 | Lab none | Installed | Bouldin Alfalfa-ADEX Anemometer Main Upper | Installed on a new post at the main tower at 6.08m alg for the advection experiment at BA |
GP-001 GP20160012 | 2022-05-10 | Vaira CO2 probe West Profile -0.16 | Removed | Lab none | Removed with the last of the soil co2 system because data not good and to reduce power load. |
GP-001 GP20160117 | 2022-05-10 | Vaira CO2 probe West Profile -0.08 | Removed | Lab none | Removed with the last of the soil co2 system because data not good and to reduce power load. |
GP-001 GP20160042 | 2022-05-10 | Vaira CO2 probe West Profile -0.02 | Removed | Lab none | Removed with the last of the soil co2 system because data not good and to reduce power load. |
GP-001 GP20170028 | 2022-05-10 | Vaira CO2 probe West Profile -0.04 | Removed | Lab none | Removed with the last of the soil co2 system because data not good and to reduce power load. |
CR23X 2299 | 2022-05-10 | Vaira Data Logger Soil CO2 | Removed | Lab none | Removed with the last of the soil co2 system because data not good and to reduce power load. |
BB-Fab BB-VR | 2022-05-10 | Vaira Battery Bank Main | Maintenance | Vaira Battery Bank Main | Fixed broken wire between the two banks of solar panels. Disconnected and load tested all the batteries. Two batteries, second from north in each box, tested bad. These were moved to the north most position and left disconnected. The other six tested good and were reconnected. |
LI-7700 TG1-0643 | 2022-05-09 | Borrowed none | Removed | Returned none | Removed from the urban tower on BWW roof because Ameriflux needs it back to do some site visits this summer. The sensor and accessories were returned to Stephen Chan of AMP when he came to our lab to visit the urban tower. Items returned: 7700, 7700 hat, wash box, brand-new wash power, brand-new wash tubing, wash box mounting hardware Items I forgot to return: ethernet cable, Licor power cable |
PQS 1 212225 | 2022-05-09 | Lab none | Returned | Returned none | Returned to Stephen Chan of AMP when he came to our lab to pick up the methane loaner from the urban tower on BWW roof. |
CNR4 120788 | 2022-05-09 | Lab none | Returned | Returned none | Returned to Stephen Chan of AMP when he came to our lab to pick up the methane loaner from the urban tower on BWW roof. |
miniDOT 1221 | 2022-05-02 | Lab none | Serviced | Lab none | I connected to this miniDOT using sneakernet and was able to adjust the sampling frequency, but could not sync the clock. Joe thought that maybe the interface is checking a time server that doesn't exist anymore, or maybe the interface cannot be used with Windows 10. He ended up setting the clock by using the old Tonzi laptop (running Windows 7) connected to an external monitor. Campus wi-fi does not allow Windows 7 to connect to the internet b/c of security issues, so he ended up using his phone as a hotspot to connect the old laptop to the internet (after some more hiccups. 2.4 vs. 5.0 GHz wifi?) The miniDOT clock was behind by 693 seconds (~12min). He synced the clock, set the sampling frequency to 5min, and put in fresh batteries (I think). I put in a fresh desiccant pack. This miniDOT only accepts 2GB SD cards. |
miniDOT 1221 | 2022-05-06 | Lab none | Installed | Gilbert Tract none | Mckenna from USGS installed this at the GT breach site next to the other USGS water sensors in the channel. They plan to service the sensors every 3 months. |
EXO fDOM 22C100780 | 2022-05-06 | Lab none | Installed | Gilbert Tract none | Mckenna from USGS installed this at the GT breach site next to the other USGS water sensors in the channel. They plan to service the sensors every 3 months. |
Mark II C003231 | 2022-04-27 | Vaira Weather Station B | Removed | Lab none | Removed from Vaira because it has not been working. I connected the wind set to the remaining Mark II unit. |
Mark I A000251 | 2021-08-18 | Lab none | Disposed | Disposed none | This unit is dead and Arable doesn't want it back. I took it apart. The lithium battery was all puffy. Birds had pecked off one of the upward sensors. Not much worth salvaging. |
Mark II C003771 | 2021-06-21 | Lab none | Disposed | Disposed none | Returned to Loreli from Arable |
Mark II C003751 | 2021-06-21 | Lab none | Disposed | Disposed none | Returned to Loreli from Arable |
Mark II C006282 | 2021-06-21 | Lab none | Disposed | Disposed none | Returned to Loreli from Arable |