Equipment and Calibration History
Page: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 [28] 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70Ser No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
LI-7500A 75H-2667 | 2020-05-19 | Lab none | Installed | Bouldin Alfalfa Gas Analyzer CO2/H2O | Installed at Bouldin Alfalfa to replace sn 0035 for calibration. |
LI-7500A 0035 | 2020-05-19 | Bouldin Alfalfa Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Bouldin Alfalfa for calibration. Replaced by sn 75H-2667. |
miniDOT-usb 899502 | 2020-05-19 | Lab none | Installed | West Pond DO Sensor A | Installed on the east side of the tower, between the scaffolding and the wooden platform. |
LI-7500A 0041 | 2020-05-19 | Lab none | Installed | West Pond Gas Analyzer CO2/H2O | Installed at West Pond to replace sn 0418 for calibration. |
LI-7500A 0418 | 2020-05-19 | West Pond Gas Analyzer CO2/H2O | Removed | Lab none | Removed from West Pond and brought back to the lab for calibration. Replaced by sn 0041. |
LI-7500A 0042 | 2020-05-19 | Lab none | Installed | East End Gas Analyzer CO2/H2O | Installed at East End to replace sn 75H-2182 for calibration. |
LI-7500A 75H-2182 | 2020-05-19 | East End Gas Analyzer CO2/H2O | Removed | Lab none | Removed from East End and brought back to the lab for calibration. Replaced by sn 0042. |
WMP 1352 000022 | 2020-05-20 | Lab none | Notes | Lab none | I was preparing sonics to loan the LBL and had problems with this sonic. It spit data for a while but then seemed to hang up consistently after several restarts. |
LI-7700 TG1-0421 | 2020-05-19 | Bouldin Alfalfa | Calibration | Bouldin Alfalfa | Calibration Location: Bouldin Alfalfa Last calibration: 2019-10-22 RSSI=76%, Optical RH=4% Ambient P=101.2kPa, Tair=19.0C Zero Air at 900psi, AMP CA3923 3.121 at 975 CH4 Zero Offset: -0.082ppm CH4 Span Offset: 0.004ppm Notes: Breezy day |
LI-7700 TG1-0155 | 2020-05-19 | Bouldin Corn | Calibration | Bouldin Corn | Calibration Location: Bouldin Corn Last calibration: 2019-12-04 RSSI=88%, Optical RH=9% Ambient P=101.6kPa, Tair=17.5C Zero Air at 900psi, AMP CA3923 3.121 at 1000 CH4 Zero Offset: 0.022ppm CH4 Span Offset: -0.001ppm Notes: Seems stable (2nd calibration after sensor fell off BC tower). Breezy day. |
LI-7700 TG1-0423 | 2020-05-19 | East End Gas Analyzer CH4 | Calibration | East End Gas Analyzer CH4 | Calibration Location: East End Last calibration: 2019-10-22 RSSI=83%, Optical RH=20% Ambient P=101.5kPa, Tair=22.5C Zero Air at 900psi, AMP CA3923 3.121 at 850 CH4 Zero Offset: 0.01ppm CH4 Span Offset: 0.006ppm Notes: Swapped optics desiccant (indicating drierite) after calibration. Used zero air cal gas to dry out head space. New RH ~7%. |
LI-7700 TG1-0224 | 2020-05-19 | West Pond Gas Analyzer CH4 | Calibration | West Pond Gas Analyzer CH4 | Calibration Location: West Pond
Last calibration: 2019-10-22 RSSI=71%, Optical RH=9% Ambient P=101.5kPa, Tair=21.5C Zero Air at 950psi, AMP CA3923 3.121 at 900 CH4 Zero Offset: -0.022ppm CH4 Span Offset: -0.003ppm Notes: Breezy day |
miniDOT-usb 899502 | 2020-01-07 | West Pond DO Sensor A | Removed | Lab none | Removed from WP and brought back to the lab because of low water levels. |
PQS 1 110340 | 2011-11-18 | Factory none | Calibration | Factory none | Initial factory calibration 4.61uV/(umol/m2/s) |
PQS 1 110337 | 2011-11-18 | Factory none | Calibration | Factory none | Initial factory calibration 4.51uV/(umol/m2/s) |
LI-7500A 75H-2176 | 2020-05-13 | Lab | Calibration | Lab | Last calibration: 2019-11-13 AGC=100 SDM= DAC1= DAC2= Ambient P=100.6kPa, Tair=21.6C, Tdew=11.9C Zero Air at 725psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.8675 -> .8672 Offset: -1.42ppm CO2 span 1.0072 -> 1.0081 Offset: -.52ppm H2O zero 0.852 -> .8521 Offset: .8ppm H2O span 0.9123 -> .9159 Offset: -.09ppm Notes: |
LI-7500A 75H-2667 | 2020-05-13 | Lab | Calibration | Lab | Last calibration: 2019-11-12 AGC=102 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=21.3C, Tdew=10.6C Zero Air at 725psi, AMP CA4396 408.97 at 500 Tdewspan=16.00 CO2 zero 0.9419 -> .9422 Offset: 1.29ppm CO2 span 1.019 -> 1.0196 Offset: -0.25ppm H2O zero 0.8384 -> 0.8380 Offset: -2.3ppm H2O span 1.0239 -> 1.0313 Offset: -0.15ppm Notes: |
LI-7500A 0042 | 2020-05-13 | Lab | Calibration | Lab | Last calibration: 2019-12-04 AGC=99.9 SDM= DAC1= DAC2= Ambient P=100.9kPa, Tair=19.9C, Tdew=9.18C Zero Air at 750psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.949 -> .9481 Offset: -3.44ppm CO2 span 1.0182 -> 1.0141 Offset: 2.03ppm H2O zero 0.8441 -> .8441 Offset: 0.1ppm H2O span 1.0341 -> 1.0271 Offset: 0.15ppm Notes: |
LI-7500A 0041 | 2020-05-13 | Lab | Calibration | Lab | Last calibration: 2019-11-12 AGC=100.9 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=21.6C, Tdew=9.7C Zero Air at 725psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.9968 -> .9966 Offset: -0.6ppm CO2 span 1.0146 -> 1.0180 Offset: -2.16ppm H2O zero 0.8218 -> .8210 Offset: -4.2ppm H2O span 1.0267 -> 1.0256 Offset: 0.02ppm Notes: |
CR1000 4811 | 2011-02-05 | Lab none | Returned | Returned none | Returned to Frank Anderson - date is approximate |
CR1000 38212 | 2011-02-03 | Lab none | Installed | Mayberry Data Logger Eddy | Installed at Mayberry to collect eddy flux and replace sn 4811 which needs to be returned to Frank Anderson. |
CR1000 4811 | 2011-02-03 | Mayberry Data Logger Eddy | Removed | Lab none | Removed from the collecting the eddy flux at Mayberry for return to Frank Anderson. Replaced by CR1000 sn 38212 |
CR1000 4811 | 2010-10-14 | Lab none | Installed | Mayberry Data Logger Eddy | Installed with the initial set up of the site. |
CS547A 5688 | 2011-11-22 | Lab none | Installed | Mayberry Conductivity Sensor A | Installed on the Tule Tower scaffolding but the data logger program is having trouble so no readings yet. |
CS547A 5688 | 2011-11-08 | Mayberry Conductivity Sensor A | Removed | Lab none | We pulled the conductivity sensor from the main tower to clean and test in the lab. Then we will reinstall it at the Tule tower. |
2300-000 2300565 | 2020-04-30 | Factory none | Returned | Lab none | Returned from repair and upgrade at Turner. The blue excitation for chlorophyll was replaced with a red excitation. |
PQS 1 110340 | 2020-04-18 | Lab none | Installed | Tonzi PAR Sensor Under-A | The PAR sensor was installed at Tonzi on the z-cam 1 post to measure below canopy PAR. It is connected the the fmet CR23x |
Mark II C002471 | 2020-11-22 | Lab none | Returned | Disposed none | Returned to Arable |
MNKID-W KW01770 | 2020-02-13 | Lab none | Disposed | Disposed none | This unit was given to us by Patty in exchange for a Morning Star unit they used when setting up their Eden Landing site. The solar system at Eden Landing fell over in the wind and the Morning Star unit was destroyed. I'm returning this unit to them in exchange for a new Morning Star unit. |
Mark II C003251 | 2020-04-17 | Lab none | Installed | Bouldin Corn Weather Station C | Installed at BC to replaced the prototype unit that was disabled and removed when the tower fell over. |
S2-431 1063 | 2020-04-17 | Lab none | Installed | Bouldin Alfalfa Narrow Band NDVI Reflected Test | Installed at BA in the reflected position. |
PAR-LITE 030380 | 2020-04-17 | Lab none | Installed | Bouldin Alfalfa PAR Sensor Under-A | Installed at BA at ground surface protected by a PVC collar to try to measure below canopy PAR. |
S2-431 1061 | 2020-04-17 | Lab none | Installed | Bouldin Alfalfa Narrow Band NDVI Incoming Test | Installed at BA in the incoming position. |
Mark II C003240 | 2020-04-17 | Lab none | Installed | Bouldin Alfalfa Weather Station C | Installed at Bouldin Alfalfa to replace sn C002469. The old one was a prototype and the new one is from the production run. |
Mark II C002469 | 2020-04-17 | Bouldin Alfalfa Weather Station C | Removed | Lab none | Removed from Bouldin Alfalfa and replaced by sn C003240. The old one was a prototype and the new one is from the production run. |
Mark II C003231 | 2020-04-18 | Lab none | Installed | Vaira Weather Station B | Installed at Vaira to replace sn C002714 on request by Arable. No known problems. |
Mark II C002714 | 2020-04-18 | Vaira Weather Station B | Removed | Lab none | Removed from Vaira for to be replaced by sn C003231 on request by Arable. No know problems. |
SRS-Pi PRI 913003007 | 2017-04-10 | Lab none | Installed | Twitchell Alfalfa Narrow Band PRI Reflected | Installed at TA as the PRI_out sensor. SDI-12 ID is F. |
SRS-Pi PRI 913003006 | 2017-04-10 | Lab none | Installed | Twitchell Alfalfa Narrow Band PRI Incoming | Installed at TA as the PRI_in sensor. SDI-12 ID is A. |
CMP 11 060039 | 2016-10-20 | Twitchell Rice none | Removed | Lab none | Removed from the Golden Radiometer experiment at Twitchell Rice and I assume brought back to the lab. |
eosFD FD20180067 | 2020-04-17 | Bouldin Corn Forced Diffusion C | Moved | Bouldin Corn Forced Diffusion C | Removed from the corn field and installed under the tower because there will be tractor work on the field soon. |
eosFD FD20180048 | 2020-04-17 | Bouldin Corn Forced Diffusion B | Removed | Lab none | Removed from BC and brought back to the lab because there will be tractor work on the field soon. |
eosFD FD20180047 | 2020-04-17 | Bouldin Corn Forced Diffusion A | Removed | Lab none | Removed from BC and brought back to the lab because there will be tractor work on the field soon. |
eosFD FD20190028 | 2020-04-17 | Lab none | Installed | Bouldin Alfalfa Forced Diffusion B | Installed with a collar at BA under the tower (SE corner) over bare soil. |
eosFD FD20160001 | 2020-04-17 | Bouldin Alfalfa Forced Diffusion A | Notes | Bouldin Alfalfa Forced Diffusion A | I tried to add a collar to this FD chamber, but the collar did not fit. I ended up reinstalling it in the same location (NE corner under the tower) over bare soil. |
SRS-Ni NDVI 2046503378 | 2017-06-05 | Lab none | Installed | West Pond Narrow Band NDVI Reflected | Installed at WP as NDVI reflected. |
2300-000 2300565 | 2020-03-23 | Lab none | Shipped | Factory none | Shipped back to Turner to swap the chlorophyll lamp from blue excitation to red excitation. However with the current shelter-in-place orders, we're not sure when they will be able to work on the unit. |
2300-000 2300565 | 2020-03-23 | Factory none | Received | Lab none | Repaired at the factory and received back on campus, but Joe will be sending it back to Turner for a chlorophyll lamp upgrade. |
2300-000 2300565 | 2020-03-05 | Lab none | Shipped | Factory none | Shipped back to Turner for repair. We did not see the CDOM UV light source (should show up as a blue light on a piece of white paper), and there was condensation/gunk inside one of the CDOM windows. |
NR-LITE 041556 | 2017-06-05 | Mayberry Net Radiometer Vegetation | Removed | Lab none | Removed from MB and brought back to the lab. It was installed over the tules and was made redundant by the 4-way radiometer. |
S2-431 1061 | 2020-04-14 | Lab none | Maintenance | Lab none | SDI-12 address changed from factory default of 0 (zero) to K |
GP-001 GP20150111 | 2020-04-03 | Sherman Wetland-Temp1 CO2 Probe | Adjusted | Sherman Wetland-Temp1 CO2 Probe | Lowered from air into shallow water by tower base. |
WM 1590 074417 | 2020-03-23 | Factory none | Returned | Lab none | Returned from Novanlynx and Gill - rebuilt from spare parts due to lost transducer, cracked spar and internal water damage. Maybe more detail on packing slip? |
GP-001 GP20160070 | 2017-05-25 | Mayberry CO2 Probe A | Moved | Mayberry CO2 Probe A | Moved to floating boom. Depth is ~-15cm below water level. Co-located with sn GP20150111 (which was removed 2017-08-16). |
GP-001 GP20160070 | 2017-05-10 | Mayberry CO2 Probe A | Moved | Mayberry CO2 Probe A | Adjusted depth? on fixed boom. Depth is -10cm based on water level on 2017-05-10. All three eosCO2 sensors (sn GP20160070, sn GP20160069, sn GP20150111) are at -10cm depth because of low water level. |
GP-001 GP20160069 | 2017-05-10 | Mayberry CO2 Probe B | Moved | Mayberry CO2 Probe A | Moved from mid position to upper position on fixed boom. Depth is -10cm based on water level on 2017-05-10. All three eosCO2 sensors (sn GP20160070, sn GP20160069, sn GP20150111) are at -10cm depth because of low water level. |
GP-001 GP20150111 | 2017-05-25 | Mayberry CO2 Probe A | Moved | Mayberry CO2 Probe A | Floating boom installed at MB. This sensor was located ~-17cm below the water level, co-located with sn GP201600070. |
GP-001 GP20150111 | 2017-05-10 | Mayberry CO2 Probe C | Moved | Mayberry CO2 Probe A | Moved from lower position to upper position on fixed boom. Depth is -10cm based on water level on 2017-05-10. All three eosCO2 sensors (sn GP20160070, sn GP20160069, sn GP20150111) are at -10cm depth because of low water level. |
GP-001 GP20140010 | 2014-10-16 | Mayberry CO2 Probe A | Moved | Mayberry CO2 Probe A | Moved lower on fence post from -5cm (based on water level on 2014-06-26) to -25cm (based on water level on 2014-10-16). |
LI-7500A 75H-2514 | 2020-03-05 | Lab none | Installed | Sherman Wetland-Temp1 Gas Analyzer CO2/H2O | Installed at Sherman Wetland to replace sn 0041 for calibration. |
LI-7500A 0041 | 2020-03-05 | Sherman Wetland-Temp1 Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Sherman Wetland-Temp1 for calibration. Replaced by sn 75H-2514. |
BB-Fab BB-SW_Temp1 | 2020-01-20 | East Pond Battery Bank | Installed | Sherman Wetland-Temp1 Battery Bank | Installed with the initial setup up of the tower. Parts last used at the East Pond site. Five size 31 Duracell deep cycle batteries (July 2018 tags). These are part number SLI31MDC and have a capacity of 105Ah. 12VDC system. |
GP-001 GP20160069 | 2020-03-11 | Mayberry CO2 Probe B | Removed | Lab none | Removed from MB (lower position) and brought back to the lab b/c it was railing high. |
CR1000 66249 | 2020-03-02 | Tonzi Data Logger IRT | Maintenance | Tonzi Data Logger IRT | I changed this data logger Pakbus id from 1 to 49 - the last two digits of its serial number. |
eosFD FD20200001 | 2020-03-02 | Lab | Installed | Vaira Forced Diffusion West | Installed near the eosGP probe profile to the west. Power from the CR10X power plug. |
LI-7500A 75H-2514 | 2020-03-02 | Lab | Calibration | Lab | Last calibration: 2019-10-30 AGC=100.2 SDM= DAC1= DAC2= Ambient P=100.5kPa, Tair=25.5C, Tdew=-6.0C Zero Air at 800psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.9047 -> .9051 Offset: 1.66ppm CO2 span 1.0064 -> 1.0104 Offset: -1.92ppm H2O zero 0.8391 -> .8393 Offset: 1.3ppm H2O span 1.0156 -> 1.0173 Offset: -.04ppm Notes: Ambient air very dry. |
GL-136 GL-136-01 | 2020-02-25 | Lab | Tested | Lab | I tested this sensor in the lab and could not get it to work. I used the current-to-voltage board provided with the sensor connected to a CR1000. I also connected a multimeter in place of the current-to-voltage board to measure the current. Both setups showed no response even when dunking the sensor in about 1.5m pipe filled with water. I recommend disposal. |
FMA RMT-200 05-0010 | 2020-02-25 | Lab | Notes | Lab | We removed the pressure controller from this unit for use in the other LGR sn 08-0114. We did not reinstall a pressure controller. |
FMA RMT-200 08-0114 | 2020-02-25 | Lab | Maintenance | Lab | We set this analyzer up after many years of sitting idle. It seemed to run okay in slow flow but the cell pressure dropped to near zero. I removed the internal 2um filter and it tested okay (easy to blow through). I ended up swapping it with another because it had been installed backwards (not that I'm sure that makes a difference) and it was easier change fittings on the other one. I blew the new filter out with air from the bench before installing. Notes indicated this analyzer had low pressure last time it was used. We swapped the pressure controller with the one from the other LGR which has a broken laser. This got the system working with 148Torr pressure and a 14us ring time. Running an AMP cal gas of 3.121ppm CH4, the analyzer agreed within +-1ppb. |
LI-7500A 0035 | 2020-02-19 | Lab | Calibration | Lab | Last calibration: 2019-11-18 AGC=100 SDM= DAC1= DAC2= Ambient P=100.95kPa, Tair=25.6C, Tdew=8.3C Zero Air at 800psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.9374 -> .9373 Offset: -.29ppm CO2 span 1.017 -> 1.0158 Offset: .43ppm H2O zero 0.898 -> .8981 Offset: .4ppm H2O span 1.0314 -> 1.0246 Offset: .14ppm Notes: |
LI-7500A 0418 | 2020-02-19 | Lab | Calibration | Lab | Last calibration: 2019-11-18 AGC=93.2 SDM= DAC1= DAC2= Ambient P=100.8kPa, Tair=28.1C, Tdew=8.2C Zero Air at 800psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.8991 -> .8994 Offset: 1.12ppm CO2 span 0.9988 -> .9987 Offset: -.74ppm H2O zero 0.8482 -> .8456 Offset: -5.4ppm H2O span 0.9812 -> .9845 Offset: -.06ppm Notes: |
LI-7500A 75H-2182 | 2020-02-19 | Lab | Calibration | Lab | Last calibration: 2019-11-18 AGC=99.4 SDM= DAC1= DAC2= Ambient P=100.94kPa, Tair=24.7C, Tdew=8.4C Zero Air at 800psi, AMP CA4396 408.97 at 550 Tdewspan=16.00 CO2 zero 0.8846 -> .8850 Offset: 1.58ppm CO2 span 1.0217 -> 1.0232 Offset: -.69ppm H2O zero 0.8462 -> .8459 Offset: -1.9ppm H2O span 1.0265 -> 1.0249 Offset: .03ppm Notes: |
GP-001 GP20150111 | 2019-10-02 | Lab none | Installed | East Pond CO2 Probe | Installed at EP. |
GP-001 GP20150111 | 2020-01-30 | East Pond CO2 Probe | Moved | Sherman Wetland-Temp1 CO2 Probe | Moved from East Pond to temporary tower at Sherman Wetland. No water near the tower to put the probe in, so it's hanging in the air for now. |
GL-136 GL-136-01 | 2020-02-20 | Mayberry 0 | Removed | Lab none | Removed from MB and brought back to the lab b/c it hasn't been comparing well to the regular CSI water level sensor. |
2300-000 2300565 | 2020-02-20 | Mayberry Fluorometer | Removed | Lab none | Removed from MB and brought back to the lab because its CDOM doesn't seem to be responding and it needs a good cleaning. |
LI-7500A 75H-2182 | 2020-02-20 | Lab none | Installed | East End Gas Analyzer CO2/H2O | Installed at East End to replace sn 75H-2514 for calibration. |
LI-7500A 75H-2514 | 2020-02-20 | East End Gas Analyzer CO2/H2O | Removed | Lab none | Removed from East End for calibration. Replaced by sn 75H-2182. |
LI-7500A 0418 | 2020-02-20 | Lab none | Installed | West Pond Gas Analyzer CO2/H2O | Installed at West Pond to replace sn 75H-2667 for calibration. |
LI-7500A 75H-2667 | 2020-02-20 | West Pond Gas Analyzer CO2/H2O | Removed | Lab none | Removed from West Pond for calibration. Replaced by sn 0418. |
LI-7500A 0035 | 2020-02-20 | Lab none | Installed | Bouldin Alfalfa Gas Analyzer CO2/H2O | Installed at Bouldin Alfalfa to replace sn 75H-2176 for calibration. |
LI-7500A 75H-2176 | 2020-02-20 | Bouldin Alfalfa Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Bouldin Alfalfa for calibration. Replaced by sn 0035. |
PA-II-SD 68c63acc07a9 | 2020-02-20 | Lab none | Installed | Bouldin Corn Air Quality Sensor | Installed at BC in an additional PVC solar/weather shield and mounted on the southwest corner post of the scaffolding. |
LI-7500A 75H-2668 | 2020-02-20 | Lab none | Installed | Bouldin Corn Gas Analyzer CO2/H2O | Installed at Bouldin Corn to replace sn 0042 for calibration. |
LI-7500A 0042 | 2020-02-20 | Bouldin Corn Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Bouldin Corn for calibration. Replaced by sn 75H-2668. |
PA-II-SD 68c63acc07a9 | 2020-02-19 | Lab | Maintenance | Lab | This sensor got wet when the tower fell down. I took it apart and discovered that only the real time clock board with battery looked corroded. The sensor ran well without the RTC battery - both particle counters agreed. And the sensor compared well with the new one running side by side. I bought a new RTC board that needed to be modified - a pin header on one side of the board was removed and a diode that enabled charging of the battery needed to be remove since standard coin cells are not rechargeable. After reassembly it ran well and was able to connect with the PurpleAir web site getting its clock reset and running firmware v4.11 |
LI-7500A 0073 | 2020-02-12 | Lab | Installed | Vaira Gas Analyzer CO2/H2O | Installed at Vaira to replace sn 0035 for calibration. |
LI-7500A 0035 | 2020-02-12 | Vaira Gas Analyzer CO2/H2O | Removed | Lab | Removed from Vaira for calibration. Replaced by sn 0073. |
LI-7500A 1594 | 2020-02-12 | Lab | Installed | Tonzi-Floor | Installed at Tonzi Floor to replace sn 0418 for calibration. |
LI-7500A 0418 | 2020-02-12 | Tonzi-Floor Gas Analyzer CO2/H2O | Removed | Lab Gas Analyzer CO2/H2O | Removed from Tonzi Floor for calibration. Replaced by sn 1594. |
LI-7500A 75H-2150 | 2020-02-12 | Lab | Installed | Tonzi-Tower Gas Analyzer CO2/H2O | Installed at Tonzi Tower to replace sn 75H-2182 for calibration. |
LI-7500A 75H-2182 | 2020-02-12 | Tonzi-Tower Gas Analyzer CO2/H2O | Removed | Lab | Removed from Tonzi Tower for calibration. Replaced by sn 75H-2150. |
LI-7500A 0073 | 2020-02-11 | Lab | Calibration | Lab | Last calibration: 2019-10-30 AGC=100.3 SDM=0 DAC1=- DAC2=- Ambient P=100.8kPa, Tair=26.4C, Tdew=-2.8C Zero Air at 800psi, AMP CA04396 408.97 at 550 Tdewspan=16.0 CO2 zero 0.9574 -> 0.9572 Offset: -0.8ppm CO2 span 1.0091 -> 1.0096 Offset: -0.37ppm H2O zero 0.7311 -> 0.7313 Offset: 0.9ppm H2O span 1.0052 -> 1.0091 Offset: -0.08ppm Notes: Ambient air very dry. |
LI-7500A 75H-2150 | 2020-02-11 | Lab | Calibration | Lab | Last calibration: 2019-08-01 AGC=101.0 SDM=0 DAC1=- DAC2=- Ambient P=100.8kPa, Tair=26.9C, Tdew=-1.45C Zero Air at 800psi, AMP CA04396 408.97 at 550 Tdewspan=16.0 CO2 zero 0.9022 -> 0.9030 Offset: 3.7ppm CO2 span 1.0086 -> 1.0154 Offset: -3.47ppm H2O zero 0.8673 -> 0.8674 Offset: 0.5ppm H2O span 1.0114 -> 1.0224 Offset: -0.23ppm Notes: First calibration after swapping chemicals and running on the bench for a week. I was expecting to see negative offsets from zero - may still drift a little lower. Ambient air very dry. |
LI-7500A 75H-2668 | 2020-02-11 | Lab | Calibration | Lab | Last calibration: 2019-10-30 AGC=100.4 SDM=0 DAC1=- DAC2=- Ambient P=100.8kPa, Tair=26.9C, Tdew=-1.59C Zero Air at 800psi, AMP CA04396 408.97 at 550 Tdewspan=16.0 CO2 zero 0.9393 -> 0.9393 Offset: -0.1ppm CO2 span 1.016 -> 1.0171 Offset: -0.94ppm H2O zero 0.9096 -> 0.9072 Offset: 2.7ppm H2O span 1.0143 -> 1.0147 Offset: -0.01ppm Notes: Ambient air very dry |
LI-7500A 1594 | 2020-02-11 | Lab | Calibration | Lab | Last calibration: 2019-10-30 AGC=101.4 SDM=0 DAC1=- DAC2=- Ambient P=100.8kPa, Tair=26.1C, Tdew=-4.92C Zero Air at 800psi, AMP CA04396 408.97 at 550 Tdewspan=16.0 CO2 zero 0.8646 -> 0.8657 Offset: 4.6ppm CO2 span 1.0166 -> 1.0203 Offset: -1.92ppm H2O zero 0.8895 -> 0.8831 Offset: -18.3ppm H2O span 0.9958 -> 1.0120 Offset: -0.34ppm Notes: Ambient air very dry. Zero offsets a bit larger than normal. |
LI-7500A 0065 | 2020-02-06 | Lab none | Installed | Mayberry Gas Analyzer CO2/H2O | Installed at Mayberry to replace sn 1594, which was brought back to the lab for calibration. |
LI-7500A 1594 | 2020-02-06 | Mayberry Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Mayberry and brought back to the lab for calibration. Replaced by sn 0065. |
LI-7500A 75H-2669 | 2020-02-06 | Lab none | Installed | Sherman Barn Gas Analyzer CO2/H2O | Installed at Sherman Barn to replace sn 75H-2668, which was brought back to the lab for calibration. |
LI-7500A 75H-2668 | 2020-02-06 | Sherman Barn Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Sherman Barn and brought back to the lab for calibration. Replaced by sn 75H-2669. |