Field Notes

<--2000-12-12 00:00:00 | 2000-12-26 00:00:00-->

Vaira: 2000-12-14 00:00:00 (DOY 349)
Author: Dennis Baldocchi
Others:

Summary: Computers crashed; energy difficulties as there is fog and no sun exposure.

Dec 14., D349

Computers crashed. Now juice from fog and no sun,

Dec. 21. Lianhong visited site today. Found system down since the 14th. Rebooted and down loaded data. Only copied Raw data as his zip drive filled up. Started to rain. Took Lai and plant height samples.
Not sure if system and flux program is correct. Had problem finding key program. But thinks so.
Need to download met data next time.
Lianhong visited Vaira grassland site, 21/12/2000, Friday. Partly cloudy.

Arrived at the site around 11:00am. Checked the power first. Battery voltage ok, but load current ~ 0.8 amp. Found computer off. Checked files stored under /Vaira and found the last day when data recorded was 12-13 –2000 and the file was G3482200.raw. Later met Mr. Vaira. And he told me there had been several very foggy days but he didn’t remember the exact date. Downloaded the *.raw data to the zip disk. Not enough space for met data. Created raw subdirectory under Vaira and move the *.raw data files to /raw. Tried to delete the *.raw data files under /Vaira. Suddenly rained and in a panic pressed the wrong button and deleted the Vaira directory. Restored the computer in the box and run into the car for shelter. Rain lasted for about an hour or also. After rain tried to restore deleted files from recycle bin (partially successful). Removed the 75H-0035 from the tower and installed the calibrated 75H-0042. Rebooted the computer and Gillsonic could not start automatically (could not find Gillsonic.exe under Vaira). Started Gillsonic but not sure if it was working.

Fixed CR-23x P1 black wire. Took four leaf area samples and measured canopy heights.

Dec 26, 2000, 1000 to 1100
Clear day, mild temps. No cows.

There was a power outage of the PC on 3482230 hours. Lianhong returned to the site on 3561100 and rebooted and started the flux system.

Field Data

No tank data

No VR Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No VR Grass Biomass data found

No VR OakLeaves Biomass data found

No VR PineNeedles Biomass data found

0 photos found

Graphs display:
9 sets found

16 VR_met graphs found

Temperatures

System Power Voltage

Soil Temperatures Set 1

Soil Temperatures Set 2

Soil Temperature Set 3

Soil Temperature at -4cm

Soil Heat Flux

Soil Moisture

Photosynthetic Active Radiation

Short/Long Wave Radiation

LED sensor

Vaira PPT

Peltier SHF Plates

Peltier SHF Temperatures

LED NDVI

NDVI SRS Raw Data

No data found for VR_flux.
No data found for VR_soilco2.
No data found for VR_pond.
Can't check TZVR_mixed
No data found for VR_fd.
No data found for VR_processed.
No data found for VR_arable.
No data found for VR_soilvue.

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.