Field Notes
<--2020-05-19 14:45:00 | 2020-06-09 09:37:00-->Other sites visited today: Sherman Barn | West Pond | Bouldin Corn | Bouldin Alfalfa | Mayberry
Phenocam link: Searching...
East End: 2020-05-29 09:50:00 (DOY 150)
Author: Joe Verfaillie
Others:
Summary: Replaced diffuse PAR motor, calibrated conductivity sensor, restarted camera.
East End 2020-05-29 I arrived at about 9:50. It was sunny and warm with high thin clouds and a strong gusty wind from the west. I did not see any goats between here and West Pond and only one gate was closed. I swapped the motor for the diffuse PAR. It was difficult in the wind and high on the scaffolding but all went well. We need to put some lubricant on the exposed part of the motor, WD40 maybe easiest. I calibrated the conductivity sensor sn 6494. It was completely submerged when I pulled it up – I forgot to check the water level. In DI water it read 0.00mS and 22.4C and in the 10mS YSI solution it read 11.3mS and 23.0C – a little high but we never see values that high at this site. I restarted the camera just in case. I left at 10:40 |
0 photos found
11 sets found
14 EE_met graphs found
Can't check EE_mixed
1 EE_mixed graphs found
8 EE_flux graphs found
Can't check MBWPEESWGT_mixed
1 EE_cam graphs found
Can't check MBEEWPSWEPGT_cam
Can't check SIMBTWEE_met
Can't check EE_Temp
5 EE_Temp graphs found
Can't check EE_minidot
1 EE_minidot graphs found
Can't check MBSWEEWPBCBA
1 EE_processed graphs found