Equipment and Calibration History
Page: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 [20] 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68Ser No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
Mark II C002445 | 2020-04-23 | Lab none | Disposed | Disposed none | Returned to Arable |
Mark II C002714 | 2020-04-23 | Lab none | Disposed | Disposed none | Returned to Arable |
Mark II C006322 | 2021-02-04 | Lab none | Installed | Bouldin Alfalfa Weather Station PL_N-B | Installed on the northern Planet Labs post to replace one of the two units eaten by the sheep |
Mark II C006282 | 2021-02-04 | Lab none | Installed | Bouldin Alfalfa Weather Station PL_N-A | Installed on the northern Planet Labs post to replace one of the two units eaten by the sheep |
Mark I A001311 | 2021-02-25 | Lab none | Disposed | Disposed none | Returned to Arable due to end of life. The was a cal val unit and was replaced by a new Mark II |
Mark I A001359 | 2021-02-25 | Lab none | Disposed | Disposed none | Returned to Arable due to end of life. The was a cal val unit and was replaced by a new Mark II |
Mark I A001353 | 2021-02-25 | Lab none | Disposed | Disposed none | Returned to Arable due to end of life. The was a cal val unit and was replaced by a new Mark II |
CR1000 23865 | 2021-02-25 | Lab none | Maintenance | Lab none | The internal lithium battery was nearly dead 1.6V. I couldn't find a new one but swapped it for one reading 2.6V instead. Be sure the check the clock when using this logger. |
CNR4 121038 | 2019-11-17 | Factory none | Calibration | Factory none | Initial calibration by Kipp and Zonen. LW on 2019-11-17: LW_in = 6.83 uV/(W/m2), LW_out = 5.48 uV/(W/m2). SW on 2019-11-15: SW_in = 14.56 uV/(W/m2), SW_out = 14.17 uV/(W/m2) |
NR01 2420 | 2021-02-18 | Lab none | Repair | Lab none | Over the last week or so I disassembled and cleaned this sensor. I don't see any water damage but I can't get the LW junction board loose as it seems glued to the case. I totally replaced the four wires running between the LW and SW sides. These wires were broken after having been previously broken and spliced. I soldered new wires directly to the junction boards. I collected about two days of data on the window sill with the sensor partially disassembled so that all four sensors could point up together. The relationship between the paired sensors was very tight (r-squared >0.99) - excluding a portion of the LW data that might have been affected by solar heating. LW had a sloped of 1.01 but SW had a slope of 1.20 - new calibration coefficients are probably needed. Today I completely reassembled the sensor and put it out the window on a boom to collect some data to check the assembly. |
PAR-LITE 990017 | 1999-02-09 | Factory none | Calibration | Factory none | Initial factory calibration: 5.16uV/(umol/m2/s) |
PAR-LITE 990019 | 1999-02-09 | Factory none | Calibration | Factory none | Initial factory calibration; 5.26uV/(umol/m2/s) |
PRB-K Type #8 000000402FF3 | 2021-02-10 | Tonzi Soil Moisture Probe F -0.50m | Removed | Lab none | Removed from Tonzi floor due to fixed readings for a long while. This sensor was out of the ground at the edge of the trees near the path to the tower. It was buried vertically with the top of the sensor 31cm below the surface - the time were 44-50cm below the surface. |
PAR-LITE 990031 | 2021-02-10 | Tonzi PAR Sensor Incoming Cal | Removed | Lab none | Removed from Tonzi Tower after three weeks of inter comparison with the AMP standard |
PAR-LITE 990025 | 2021-02-10 | Cal Kit PAR Sensor Incoming | Removed | Lab none | Removed from TZ Tower after three weeks of inter comparison with the AMP standard |
WM 1590 153805 | 2021-02-10 | Lab none | Installed | Cal Kit Anemometer | Installed on the TZ Tower for inter-comparison. This sensor is the one that got wet when the BC tower fell over. It's mounted on the post just north of the main eddy sensors, at the same height, and oriented to true north. |
eosFD FD20200001 | 2021-02-10 | Lab none | Installed | Vaira Forced Diffusion North | Installed near the old north soil co2 profile. This unit has a homemade solar shield to try to keep it cooler. Could use a soil collar. |
eosFD FD20200001 | 2021-02-04 | Factory none | Returned | Lab none | Returned from Eosense where its pump relay board was replaced under warranty repair. |
GP-001 GP20140026 | 2021-02-04 | West Pond CO2 Probe B | Removed | Lab none | Removed from WP and brought back to the lab b/c this sensor has been reading noise since late Nov |
LI-7500A 1594 | 2021-02-01 | Lab | Calibration | Lab | Last calibration: 2020-08-20 AGC=99.3 SDM=0 DAC1=- DAC2=- Ambient P=100.3kPa, Tair=28.4C, Tdew=11.0C Zero Air at 0psi, AMP CA04396 408.97 at 0 Tdewspan=20.0 CO2 zero 0.8651 -> 0.8646 Offset: -2.1ppm CO2 span 1.02124 -> 1.0131 Offset: -0.32ppm H2O zero 0.8838 -> 0.8890 Offset: 29.85ppm H2O span 1.015 -> 1.000 Offset: 0.35ppm Notes: The usual 7550 box in the lab is running the newest firmware v8.8 and is complaining that the v8.5 config file has bad number formats for GPS locations. I used 7550 sn AIU-1866 for calibration instead. This box and head will go to replace equipment on the BC tower that fell in the water. |
NR01 2420 | 2021-01-30 | Lab none | Damaged | Lab none | This sensor was removed from a submerged position on the fallen BC tower. The shortwave side had been torn loose breaking the wires similar to last time it was damaged. After returning to the lab on the 29th I pulled it apart and tried to air it out. On the 30th it was still damp inside and I ran dry air through the holes under the circuit boards for two days. |
WM 1590 153805 | 2021-02-01 | Lab none | Tested | Lab none | After being removed from a partially submerged position on the fallen BC tower, I tested this sensor in the lab. There was no evidence that water had leaked inside. I connected it to a Licor system and used fans to blow air through in on the floor. The response sign and magnitude looked about right. I plan to run it on the Tonzi tower for a couple weeks to check its performance. |
LI-7500A 75H-2176 | 2021-02-01 | Lab none | Tested | Lab none | On the 29th after being retrieved from a partially submerged position on the fallen BC tower, I removed the desiccant bottles and saw no evidence that water had gotten inside. I flowed dry air into the desiccant bottle openings over night. On the 1st, after consultation with Licor, I powered up this head on the calibration rig in the lab. It seemed to operate fine. I flooded the base with zero air before sealing it back up but it needs to run for a while to equilibrate and be calibrated. |
LI-7700 TG1-0155 | 2021-02-04 | Lab none | Shipped | Factory none | Shipped to Licor and RMA 00225226 for evaluation after being submerged when the BC tower fell in the storm last week. |
LI-7700 TG1-0155 | 2021-02-01 | Lab none | Tested | Lab none | On the 29th I removed this sensor from being submerged after the BC tower fell just after midnight on the morning of the 27th. On the evening of the 29th, about 1/2 cup of water came out of the bottom when I removed the base. I removed the desiccant bottle in the head and saw no evidence that water had leaked in there. I left dry air flowing inside the base over night. On the 30th I removed the bottom case and only saw minor water damage on the pressure sensor. On the 1st, after consultation with Licor, I powered up the analyzer and got green power and status lights but no communications on the Ethernet. It will need to be returned to Licor for further evaluation. |
SRS-Pi PRI 897103002 | 2021-02-03 | Lab none | Installed | Bouldin Corn Narrow Band PRI Reflected | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
SRS-Ni NDVI 2046503357 | 2021-02-03 | Lab none | Installed | Bouldin Corn Narrow Band NDVI Reflected | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
SRS-Ni NDVI 882103020 | 2021-02-03 | Lab none | Installed | Bouldin Corn Narrow Band NDVI Incoming | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
CNR1 990181 | 2021-02-03 | Lab none | Installed | Bouldin Corn Net Radiometer 4-way | Installed on the BC tower to replace the Hukseflux NR01 that broke when the tower fell and still needs repair and cross comparison. |
Mark II C006123 | 2021-02-03 | Lab none | Installed | Bouldin Corn Weather Station B | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
Mark II C003251 | 2021-02-03 | Lab none | Installed | Bouldin Corn Weather Station C | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
PA-II-SD 68c63acc07a9 | 2021-02-03 | Lab none | Installed | Bouldin Corn Air Quality Sensor | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
SD130BN 0030F4D21491 | 2021-02-03 | Lab none | Installed | Bouldin Corn Camera | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
PQS 1 140441 | 2021-02-03 | Lab none | Installed | Bouldin Corn PAR Sensor Reflected | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
PQS 1 140453 | 2021-02-03 | Lab none | Installed | Bouldin Corn PAR Sensor Incoming | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
SRS-Pi PRI 913003004 | 2021-02-03 | Lab none | Installed | Bouldin Corn Narrow Band PRI Incoming | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
LI-7500A 1594 | 2021-02-03 | Lab none | Installed | Bouldin Corn Gas Analyzer CO2/H2O | Installed on the BC tower to replace sensors damaged when the tower fell last week |
LI-7550 AIU-1866 | 2021-02-03 | Lab none | Installed | Bouldin Corn Interface LI-7550 | Installed on the BC tower to replace sensors damaged when the tower fell last week |
LI-7700 TG1-0224 | 2021-02-03 | Lab none | Installed | Bouldin Corn Gas Analyzer CH4 | Installed on the BC tower to replace sensors damaged when the tower fell last week |
WM 1590 153803 | 2021-02-03 | Lab none | Installed | Bouldin Corn Anemometer | Installed on the BC tower to replace sensors damaged when the tower fell last week |
WL16U 57278 | 2018-05-08 | Lab none | Repair | Lab none | I stripped off the old rotting insulation and then slid on a long continuous piece of heat shrink. I shrunk the whole length of the cable. I disassembled the data logging enclosure and kept only the data logger board and USB connector in the end cap. I cut off the twin 9V battery plugs and will power the sensor from solar connected rechargeable battery. |
WL16U 57278 | 2018-03-27 | Tonzi Water Level Floor | Removed | Lab none | Removed from the Floor Well. The cable insulation is rotting and needs to be replaced. Replaced by the new METER water level sensor a couple of weeks ago. |
CMTD-As4s0 3317052234210 | 2018-05-11 | Lab none | Installed | Tonzi none | Installed at the Road Well to power Global Water sensor. |
WL16U 57278 | 2018-05-11 | Lab none | Installed | Tonzi Water Level Road | Installed at the Road Well to measure water level at 5min intervals storing 30min averages |
Mark II C006123 | 2021-01-29 | Bouldin Corn Weather Station B | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Maybe some rain in the Tair bulge |
Mark II C003251 | 2021-01-29 | Bouldin Corn Weather Station C | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Maybe some rain in the Tair bulge |
PA-II-SD 84f3ebd5ffb1 | 2021-01-29 | Bouldin Corn Air Quality Sensor | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Got rained on and the power connector is corroded |
SD130BN 0030F4D21491 | 2021-01-29 | Bouldin Corn Camera | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
SRS-Pi PRI 897103002 | 2021-01-29 | Bouldin Corn Narrow Band PRI Reflected | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
SRS-Pi PRI 913003004 | 2021-01-29 | Bouldin Corn Narrow Band PRI Incoming | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. |
SRS-Ni NDVI 2046503357 | 2021-01-29 | Bouldin Corn Narrow Band NDVI Reflected | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
SRS-Ni NDVI 882103020 | 2021-01-29 | Bouldin Corn Narrow Band NDVI Incoming | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
PQS 1 140441 | 2021-01-29 | Bouldin Corn PAR Sensor Reflected | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
PQS 1 140453 | 2021-01-29 | Bouldin Corn PAR Sensor Incoming | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
NR01 2420 | 2021-01-29 | Bouldin Corn Net Radiometer 4-way | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged and broken in two pieces |
LI-7550 AIU-0614 | 2021-01-29 | Bouldin Corn Interface LI-7550 | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. |
WM 1590 153805 | 2021-01-29 | Bouldin Corn Anemometer | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Partially submerged |
LI-7700 TG1-0155 | 2021-01-29 | Bouldin Corn Gas Analyzer CH4 | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
LI-7500A 75H-2176 | 2021-01-29 | Bouldin Corn Gas Analyzer CO2/H2O | Removed | Lab none | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Partially submerged |
Mark II C003800 | 2021-01-21 | Bouldin Alfalfa Weather Station PL_N-A | Removed | Lab none | Removed from the northeast Planet Labs location due to broken antenna caused by sheep |
Mark II C003789 | 2021-01-21 | Bouldin Alfalfa Weather Station PL_N-B | Removed | Lab none | Removed from the northwest Planet Labs location due to broken antenna caused by sheep |
Mark II C006164 | 2021-01-21 | Lab none | Installed | Bouldin Alfalfa Weather Station B | Installed at Bouldin Alfalfa to replace Mark I sn A001311 which are being phased out. |
Mark I A001311 | 2021-01-21 | Bouldin Alfalfa Weather Station B | Removed | Lab none | Removed from Bouldin Alfalfa as Mark I's are being phased out. Replaced by Mark II sn C006164. |
Mark II C006123 | 2021-01-21 | Lab none | Installed | Bouldin Corn Weather Station B | Installed at Bouldin Corn to replace Mark I sn A001359 which is being phased out. |
Mark I A001359 | 2021-01-21 | Bouldin Corn Weather Station B | Removed | Lab none | Removed from Bouldin Corn as Mark I's are phased out. Replaced by Mark II sn C006123. |
Mark II C006160 | 2021-01-21 | Lab none | Installed | Vaira Weather Station A | Installed at Vaira to replace Mark I sn A001353 which is being phased out. |
Mark I A001353 | 2021-01-21 | Vaira Weather Station A | Removed | Lab none | Removed from Vaira as Mark I's are being phased out. Replaced by Mark II sn C006160. |
Mark I A001353 | 2019-04-30 | Lab none | Installed | Vaira Weather Station A | Arable Mark I installed for CalVal inter-comparison |
PAR-LITE 060831 | 2021-01-21 | Lab none | Installed | Cal Kit PAR Sensor Incoming | Installed at TZ in the incoming position as part of the inter-comparison kit to test PAR, AirT and RH on the top of the Tower. |
PAR-LITE 990031 | 2021-01-21 | Lab none | Installed | Tonzi none | Installed as part of the inter-comparison kit to test PAR, AirT and RH on the top of the Tower. |
PAR-LITE 990025 | 2021-01-21 | Lab none | Installed | Cal Kit PAR Sensor Incoming | Installed at TZ as part of the inter-comparison kit to test PAR, T/RH on the top of the Tower. |
HMP155 S3410851 | 2021-01-21 | Lab none | Installed | Cal Kit RH & Temp | Installed as part of the inter-comparison kit to test PAR, AirT and RH on the top of the Tower. |
CR1000 4190 | 2021-01-21 | Lab none | Installed | Cal Kit Data Logger | Installed at TZ as part of the inter-comparison kit to test PAR, T/RH on the top of the Tower. |
GP-001 GP20140084 | 2021-01-21 | Lab none | Tested | Lab none | This sensor is dead. Tested in the lab and no response from CO2 or T. The connector at the top of the sensor twists loose from the body of the sensor. There was some corrosion in the connector head and the cable. |
2300-000 2300565 | 2021-01-17 | Mayberry Fluorometer | Removed | Lab none | Removed from MB and brought back to the lab for further testing b/c it has noisy data |
GP-001 GP20140084 | 2021-01-17 | Sherman Wetland CO2 Probe | Removed | Lab none | Removed from SW and brought back to the lab b/c the sensor is bad and only outputting noise |
LI-7550 AIU-1570 | 2021-01-17 | West Pond Interface LI-7550 | Upgrade | West Pond Interface LI-7550 | Upgraded embedded software from v8.5.0 to v8.8.32 in hopes this will solve the persistent 7700 sync issue |
HMP155 R0360206 | 2021-01-17 | Cal Kit RH & Temp | Moved | West Pond RH & Temp | Moved from Comparison Set to tower to replace sn G4540025 which had high RH readings. |
HMP60 G4540025 | 2021-01-17 | West Pond RH & Temp | Removed | Lab none | Removed from WP and brought back to the lab b/c RH was railing high. It was replaced by HMP155 from the Comparison Set, sn R0360206. |
NL115 9774 | 2016-08-12 | Lab none | Installed | Bouldin Alfalfa none | Installed at BA with initial site set up |
NL115 13056 | 2017-04-26 | Lab none | Installed | Bouldin Corn none | Installed at BC with initial set up of site |
eosFD FD20160001 | 2020-12-18 | Lab none | Installed | Bouldin Alfalfa Forced Diffusion A | Installed to replace the FD Chamber with the high temperature startup problems. |
eosFD FD20180047 | 2020-12-18 | Bouldin Alfalfa Forced Diffusion A | Removed | Lab none | Removed from Bouldin Alfalfa. This one has high temperature start up issues and was running on a relay to restart it every night. I removed the relay too but did not update the CR1000 program. |
CR23X 2299 | 2020-11-11 | Lab none | Installed | Vaira Data Logger Soil CO2 | Installed at Vaira in the Soil CO2 system. The 0-5V range on the 23x avoids the problem of needing voltage dividers. |
eosFD FD20190028 | 2020-12-18 | Lab none | Installed | Vaira Forced Diffusion West | Installed at Vaira West to replace sn FD20200001 for test of high temp readings in the lab. |
eosFD FD20200001 | 2020-12-18 | Vaira Forced Diffusion West | Removed | Lab none | Removed from Vaira West for testing to high temp reading in the lab. Replaced by sn FD20190028 |
CR23X 2299 | 2020-12-18 | Vaira Data Logger Soil CO2 | Location | Vaira Data Logger Soil CO2 | Confirmed serial number and location |
TE525 48130-611 | 2020-12-18 | Tonzi none | Removed | Lab none | Removed from OSU SP1 for experiments in the lab. The cable was disconnected inside the tipping bucket and left in place in the field. |
CS547A 5688 | 2020-12-16 | Lab none | Installed | Sherman Wetland Conductivity Sensor | Installed at SW. Temperature sensor is broken, so 2 temperature wires were left loose. |
eosFD FD20160001 | 2020-12-17 | Factory none | Returned | Lab none | Returned from repair at Eosense. They replaced the CO2 board and sensor, the internal battery and the conical membranes. They did and FD calibration and a FD FGen on 2020-12-14. |
eosFD FD20190028 | 2020-12-17 | Factory none | Returned | Lab none | Returned from Eosense after repair. They replaced relay board 1 and 2 and did a Flux calibration on 2020-12-01 |
LI-7500A 75H-2514 | 2020-12-11 | Lab | Calibration | Lab | Last calibration: 2020-11-30 AGC=99.9 SDM= DAC1= DAC2= Ambient P=100.9kPa, Tair=21.5C, Tdew=7.8C Zero Air at 600psi, AMP CA4396 408.97 at 300 Tdewspan=20.00 CO2 zero 0.905 -> .9049 Offset: -.14ppm CO2 span 1.0152 -> 1.0082 Offset: 3.4ppm H2O zero 0.8398 -> .8398 Offset: .1ppm H2O span 1.0238 -> 1.0093 Offset: .32ppm Notes: 2nd calibration after chemical swap on 11/24. CO2/H2O zeros calibrated on 12/11. CO2/H2O spans calibrated on 12/14 (ambient dewpt=6.08C). CO2 span offset large. |
CS547A 5688 | 2020-12-11 | Lab none | Tested | Lab none | Tested in the lab with both Campbell interface and homemade interface sn 547-01. In either case, the temperature read high, around 40 degC when it should've been around 20-25 degC. I unwrapped an old splice in the cable, but it looked perfectly fine, so I think the temperature sensor is just bad. We can still use this sensor in the future, but we'll need to be careful to do the temperature correction with another temperature sensor in the water (e.g., from water level sensor or a water thermocouple). |
A547 547-01 | 2020-12-09 | Mayberry Interface A547 | Removed | Lab none | Removed from MB along with conductivity sensor sn 5688. Temperature reading is high so brought back to the lab for testing. |
A547 547-02 | 2020-12-09 | Lab none | Installed | Mayberry Interface A547 | Installed with conductivity sensor sn 7157 at MB. |
CS547A 7157 | 2020-12-09 | Lab none | Installed | Mayberry Conductivity Sensor A | Installed at MB with interface sn 547-02 to replace sn 5688, which was brought back to the lab for testing. |
CS547A 5688 | 2020-12-09 | Mayberry Conductivity Sensor A | Removed | Lab none | Removed from MB and brought back to the lab for testing. Temperature reading is too high. |
LI-7500A 0073 | 2020-12-09 | Lab none | Installed | Mayberry Gas Analyzer CO2/H2O | Installed at Mayberry to replace sn 75H-2669 for calibration. |
LI-7500A 75H-2669 | 2020-12-09 | Mayberry Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Mayberry for calibration. Replaced by sn 0073. |
LI-7500A 0065 | 2020-12-09 | Lab none | Installed | Sherman Wetland Gas Analyzer CO2/H2O | Installed at Sherman Wetland to replace sn 75H-2667 for calibration. |