Equipment and Calibration History
Page: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 [40] 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68Ser No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
GMM222 L2010070 | 2017-09-14 | Lab none | Installed | Vaira CO2 probe North Profile -0.08 | Reinstalled at Vaira in the North profile at -8cm after lab calibration. |
GMP222 K1310103 | 2017-09-14 | Lab none | Installed | Vaira CO2 probe East Profile -0.04 | Reinstalled at Vaira in the North profile at -4cm after lab calibration. |
GMT222 G0230062 | 2017-09-14 | Lab none | Installed | Vaira CO2 probe North Profile -0.02 | Reinstalled at Vaira in the North profile at -2cm after lab calibration. |
GMP222 Y2030049 | 2017-09-14 | Lab none | Installed | Vaira CO2 probe East Profile -0.08 | Reinstalled at Vaira in the East profile at -8cm after lab calibration. |
GMP222 K1350102 | 2017-09-14 | Lab none | Installed | Vaira CO2 probe East Profile -0.04 | Reinstalled at Vaira in the East profile at -4cm after lab calibration. |
GMP222 Y2009109 | 2017-09-14 | Lab none | Installed | Vaira CO2 probe East Profile -0.02 | Reinstalled at Vaira in the East profile at -2cm after lab calibration. |
GMP221 Y0850004 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree2 Profile -0.16 | Installed at Tonzi in the Tree 2 profile at -16cm after lab calibration. This is a new installation with new holes dug. |
GMT221 F4960020 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree2 Profile -0.08 | Installed at Tonzi in the Tree 2 profile at -8cm after lab calibration. This is a new installation with new holes dug. |
GMP222 K1350103 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree2 Profile -0.04 | Installed at Tonzi in the Tree 2 profile at -4cm after lab calibration. This is a new installation with new holes dug. |
GMP222 Z2720014 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree2 Profile -0.02 | Installed at Tonzi in the Tree 2 profile at -2cm after lab calibration. This is a new installation with new holes dug. |
GMP221 Y2009100 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree1 Profile -0.16 | Installed at Tonzi in the Tree 1 profile at -16cm after lab calibration. This is a new installation with new holes dug. |
GMT221 G0150036 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree1 Profile -0.08 | Installed at Tonzi in the Tree 1 profile at -8cm after lab calibration. Using old tube at -8cm. |
GMT221 G0150035 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree1 Profile -0.04 | Installed at Tonzi in the Tree 1 profile at -4cm after lab calibration. This is a new installation with new holes dug. |
GMM222 L2010069 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Tree1 Profile -0.02 | Installed at Tonzi in the Tree 1 profile at -2cm after lab calibration. This is a new installation with new holes dug. |
GMT221 G0150037 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Open Profile -0.16 | Installed at Tonzi in the Open profile at -16cm after lab calibration. This is a new installation with new holes dug. |
GMP221 K1340006 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Open Profile -0.08 | Installed at Tonzi in the Open profile at -8cm after lab calibration. This is a new installation with new holes dug. |
GMP222 Z2720015 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Open Profile -0.04 | Installed at Tonzi in the Open profile at -4cm after lab calibration. This is a new installation with new holes dug. |
GMP222 K1310104 | 2017-09-14 | Lab none | Installed | Tonzi CO2 Probe Open Profile -0.02 | Installed at Tonzi in the Open profile at -2cm after lab calibration. This is a new installation with new holes dug. |
SRS-Nr NDVI 943203017 | 2017-09-07 | Lab none | Installed | Tonzi | Installed on the post holding the floor met data logger box. This sensor is point to the north and about 30 degrees up to see just the trees and not the grass. |
LI-7500A 0041 | 2017-09-11 | Lab none | Calibration | Lab none | Last calibration: 2017-05-05 AGC=98.4 SDM=0 DAC1=0 DAC2=0 Ambient P=100.2kPa, Tair=26.5C, Tdew=13.0C Zero Air at 900psi, AMP Air 408.97 at 2075 Tdewspan=16.00 CO2 zero 0.9969 -> .9969 Offset: -.01ppm CO2 span 1.0177 -> 1.0155 Offset: 1.05ppm H2O zero 0.821 -> .82 Offset: -5.4ppm H2O span 1.032 -> 1.0217 Offset: .22ppm Notes: |
GP-001 GP20160071 | 2017-09-08 | Lab none | Replaced | Disposed | This sensor was given to Jennifer Soong in Margaret Torn's lab with five others in exchange six new ones at a later date. Their new sensors would not arrive in time for deployment. |
GP-001 GP20160072 | 2017-09-08 | Lab none | Replaced | Disposed | This sensor was given to Jennifer Soong in Margaret Torn's lab with five others in exchange six new ones at a later date. Their new sensors would not arrive in time for deployment. |
GP-001 GP20150104 | 2017-09-08 | Lab none | Replaced | Disposed | This sensor was given to Jennifer Soong in Margaret Torn's lab with five others in exchange six new ones at a later date. Their new sensors would not arrive in time for deployment. |
GP-001 GP20150105 | 2017-09-08 | Lab none | Replaced | Disposed | This sensor was given to Jennifer Soong in Margaret Torn's lab with five others in exchange six new ones at a later date. Their new sensors would not arrive in time for deployment. |
GP-001 GP20150103 | 2017-09-08 | Lab none | Replaced | Disposed | This sensor was given to Jennifer Soong in Margaret Torn's lab with five others in exchange six new ones at a later date. Their new sensors would not arrive in time for deployment. |
GP-001 GP20150102 | 2017-09-08 | Lab none | Replaced | Disposed | This sensor was given to Jennifer Soong in Margaret Torn's lab with five others in exchange six new ones at a later date. Their new sensors would not arrive in time for deployment. |
eosFD FD20160001 | 2017-09-06 | Lab none | Installed | Twitchell Alfalfa Forced Diffusion | Reinstalled with new 90 degree cable after factory refurb. |
LI-7500A 0035 | 2017-09-06 | Lab none | Installed | Twitchell Alfalfa Gas Analyzer CO2/H2O | Installed on Twitchell Alfalfa to replace sn 1594 for calibration. |
LI-7500A 1594 | 2017-09-06 | Twitchell Alfalfa Gas Analyzer CO2/H2O | Removed | Lab none | Removed from Twitchell Alfalfa for calibration. Replaced by sn 0035. |
LI-7500A 0035 | 2017-09-05 | Lab none | Calibration | Lab none | Last calibration: 2017-05-08 AGC=99.8 SDM=0 DAC1=0 DAC2=0 Ambient P=100.4kPa, Tair=29.1C, Tdew=18.4C Zero Air at 1000psi, AMP Air 408.97 at 2100 Tdewspan=16.00 CO2 zero 0.9381 -> .9373 Offset: -3.34ppm CO2 span 1.023 -> 1.0084 Offset: 7.67ppm H2O zero 0.8974 -> .8976 Offset: .8ppm H2O span 1.0261 -> 1.0141 Offset: .25ppm Notes: |
GP-001 GP20140016 | 2017-08-16 | Lab none | Installed | Sherman Wetland CO2 Probe | Installed at SW. I waterproofed the cable-sensor connection with multiple layers of liquid electrical tape and silicone caulk. |
GP-001 GP20150101 | 2017-08-16 | Sherman Wetland CO2 Probe | Removed | Lab none | Removed from SW because it did not have a waterproof sensor-cable connection. |
LI-7500A 75H-2667 | 2017-08-16 | Lab none | Installed | Sherman Wetland Gas Analyzer CO2/H2O | Installed at SW to replace sn 75H-2182. |
LI-7500A 75H-2182 | 2017-08-16 | Lab none | Calibration | Lab none | Last calibration: 2017-04-20 AGC=87.5 SDM=0 DAC1=0 DAC2=0 Ambient P=100.4kPa, Tair=23.9C, Tdew=12.7C Zero Air at 1075psi, AMP Air 408.97 at 2000 Tdewspan=16.00 CO2 zero 0.8838 -> .8832 Offset: -2.73ppm CO2 span 1.0164 -> 1.0123 Offset: 2.13ppm H2O zero 0.8454 -> .8436 Offset: -11.4ppm H2O span 1.0139 -> 1.0038 Offset: .2ppm Notes: |
LI-7500A 75H-2180 | 2017-08-16 | Lab none | Calibration | Lab none | Last calibration: 2017-04-20
AGC=100.3 SDM= DAC1= DAC2= Ambient P=100.4kPa, Tair=23.1C, Tdew=13.9C Zero Air at 1075psi, AMP Air 408.97 at 2000 Tdewspan=16.00 CO2 zero 0.9144 -> .9129 Offset: -6.82ppm CO2 span 1.026 -> 1.0145 Offset: 5.95ppm H2O zero 0.8861 -> .8871 Offset: 6.2ppm H2O span 1.023 -> 1.0164 Offset: .14ppm Notes: |
LI-7500A 75H-2669 | 2017-08-16 | Lab none | Installed | Mayberry Gas Analyzer CO2/H2O | Installed at MB to replace sn 75H-2180. |
LI-7500A 75H-2180 | 2017-08-16 | Mayberry Gas Analyzer CO2/H2O | Removed | Lab none | Removed from MB for calibration and replaced with sn 75H-2669 |
LI-7550 AIU-1285 | 2017-08-16 | Mayberry Interface LI-7550 | Upgrade | Mayberry Interface LI-7550 | The firmware was upgraded from v8.0.0 to v8.7.5 |
HFP01 001604 | 2017-08-30 | East End-Temp1 Heat Flux Plate A | Removed | Lab none | Removed from Temporary Tower #1 Open Water. Its cable was chewed through. |
GMM222 L2030064 | 2016-01-12 | Twitchell Alfalfa | Removed | Lab none | Removed from Twitchell Alfalfa with the FD chamber due to torn membranes. |
GMM222 L2030063 | 2016-01-12 | Twitchell Alfalfa | Removed | Lab none | Removed from Twitchell Alfalfa with the FD chamber due to torn membranes. |
eosFD FD20160001 | 2017-07-05 | Lab none | Shipped | Factory | Shipped to Eosense for replacement of failed pump. Eosense provided shipping on UPS. |
GMP222 Y2030049 | 2017-08-25 | Vaira CO2 probe East Profile -0.08 | Removed | Lab none | Removed from Vaira from East profile -8 cm position for calibration |
GMP222 K1310103 | 2017-08-25 | Vaira CO2 probe East Profile -0.04 | Removed | Lab none | Removed from Vaira from East profile -4 cm position for calibration |
GMP222 Y2009109 | 2017-08-25 | Vaira CO2 probe East Profile -0.02 | Removed | Lab none | Removed from Vaira from East profile -2 cm position for calibration. Probe labeled 4. |
GMM222 L2010068 | 2017-08-25 | Vaira CO2 probe North Profile -0.04 | Removed | Lab none | Removed from Vaira from North profile -4 cm position for calibration |
GMT222 G0230062 | 2017-08-25 | Vaira CO2 probe North Profile -0.02 | Removed | Lab none | Removed from Vaira from North profile -2 cm position for calibration |
GMP222 K1350101 | 2017-08-25 | Vaira CO2 probe West Profile -0.08 | Removed | Lab none | Removed from Vaira from West profile -8 cm position for calibration |
GMP222 K1350102 | 2017-08-25 | Vaira CO2 probe West Profile -0.04 | Removed | Lab none | Removed from Vaira from West profile -4 cm position for calibration |
GMP222 K1350103 | 2017-08-25 | Vaira CO2 probe West Profile -0.02 | Removed | Lab none | Removed from Vaira from West profile -2 cm position for calibration |
GMP222 Z2720012 | 2017-08-25 | Tonzi | Notes | Lab none | Removed CO2 probe from Tonzi Tree2 profile at -2 cm. It was sn Z2720014, not sn Z2720012. Not sure where sn Z2720012 is. |
GMP222 X4840007 | 2017-08-25 | Tonzi | Notes | Lab none | We removed the CO2 probe at the Tree 2 profile at -2 cm position. The probe was sn Z2720014. Not sure where sn X4840007 is. |
GMP222 Z2720014 | 2017-08-25 | Tonzi CO2 Probe Tree2 Profile -0.02 | Removed | Lab none | Removed from Tonzi Tree 2 profile at -2 cm position for calibration |
GMT221 F4960020 | 2017-08-25 | Tonzi CO2 Probe Tree2 Profile -0.08 | Removed | Lab none | Removed from Tonzi Tree 2 profile at -8 cm position for calibration |
GMP222 K1310104 | 2017-08-25 | Tonzi CO2 Probe Tree2 Profile -0.04 | Removed | Lab none | Removed from Tonzi Tree 2 profile at -4 cm position for calibration |
GMT221 G0150036 | 2017-08-25 | Tonzi CO2 Probe Tree1 Profile -0.08 | Removed | Lab none | Removed from Tonzi Tree 1 profile at -4 or -8 cm position for calibration. Probe labeled 8. |
GMT221 G0150035 | 2017-08-25 | Tonzi CO2 Probe Tree1 Profile -0.04 | Removed | Lab none | Removed from Tonzi Tree 1 profile at -4 or -8 cm position for calibration. Probe labeled 16. |
GMM222 L2010069 | 2017-08-25 | Tonzi CO2 Probe Tree1 Profile -0.02 | Removed | Lab none | Removed from Tonzi Tree 1 profile at -2 cm position for calibration |
GMP221 K1340006 | 2017-08-25 | Tonzi CO2 Probe Open Profile -0.08 | Removed | Lab none | Removed from Tonzi Open profile at -8 cm position for calibration |
GMP222 Z2720015 | 2017-08-25 | Tonzi CO2 Probe Open Profile -0.04 | Removed | Lab none | Removed from Tonzi Open profile at -4 cm position for calibration |
GMP222 K1310102 | 2017-08-25 | Tonzi CO2 Probe Open Profile -0.02 | Removed | Lab none | Removed from Tonzi Open profile at -2 cm position for calibration |
SRS-Nr NDVI 943103015 | 2017-08-25 | Lab none | Installed | Tonzi-Tower | Installed at Tonzi tower in the outgoing (down) position, pointing toward the grass by the tower. |
SRS-Ni NDVI 1066703767 | 2017-08-25 | Lab none | Installed | Tonzi-Tower | Installed at Tonzi tower in the outgoing (down) position. |
SRS-Ni NDVI 2046503398 | 2017-08-25 | Lab none | Installed | Tonzi-Tower | Installed at Tonzi tower in the incoming (up) position. |
PAR-LITE 010164 | 2017-08-25 | Lab none | Installed | Tonzi-Tower | Installed at Tonzi tower to replace an old PAR sensor sn 010159 that was reading high. It was installed in the incoming (up) position. |
PAR-LITE 010159 | 2017-08-25 | Tonzi-Tower | Removed | Lab none | Removed from Tonzi Tower. This sensor has been reading high for a long time. The cable is decayed and the sensor needs to be re-calibrated. This sensor was entered into the database. |
PAR-LITE 990017 | 2017-08-25 | none | Notes | none | Removed incoming PAR-Lite from Tonzi tower. It was sn 010159. Not sure where PAR-Lite sn 990017. |
CR23X 2300 | 2017-08-25 | Tonzi-Tower | Removed | Lab none | Removed from Tonzi tower met as part of an upgrade to move met sensors from the CR23X to a CR1000. |
CMP 11 996981 | 2017-08-25 | Tonzi-Tower | Removed | Lab none | Removed from Tonzi Tower and brought back to the lab. It is a redundant measurement with the 4-way radiometer. Cables are decayed and need to be replaced. |
PAR-LITE 060868 | 2017-08-25 | Tonzi-Tower | Removed | Lab none | Removed this sensor as part of a rotating shadow band ensemble from Tonzi Tower because it is a redundant measurement with the BF5. |
NR-LITE 990351 | 2017-08-25 | Tonzi-Tower | Removed | Lab none | Removed from Tonzi Tower and brought back to the lab. It is a redundant measurement with the 4-way radiometer. Cables are decayed and need to be replaced. |
CR23X 2300 | 2009-02-02 | Lab none | Calibration | Lab none | Calibrated at CSI. Due Date 02 Feb 11. |
HMP60 L2310711 | 2017-08-25 | Tonzi | Removed | Lab none | Removed from Tonzi and brought back to the lab. It was installed for a comparison with an HMP45. The sensor is ready to use. |
GMM222 L2010070 | 2017-08-25 | Vaira CO2 probe North Profile -0.08 | Removed | Lab none | Removed from Vaira North profile, -8 position and brought back to the lab for calibration |
eosFD FD20160001 | 2017-08-28 | Factory | Received | Lab none | Received FD chamber back in the lab. No documentation about what they inspected/fixed. |
eosFD FD20160001 | 2017-06-23 | Twitchell Alfalfa Forced Diffusion | Removed | Lab none | Removed from Twitchell Alfalfa and brought back to lab to send back to Eosense |
CR1000 47108 | 2017-08-23 | Twitchell Alfalfa Data Logger Met | Upgrade | Twitchell Alfalfa Data Logger Met | The OS was upgraded from probably v24 to v31.08. OS v31.08 is FAT32 and reset the CR1000 to factory settings. |
LI-7550 AIU-1557 | 2017-08-23 | Twitchell Alfalfa Interface LI-7550 | Upgrade | Twitchell Alfalfa Interface LI-7550 | The firmware was upgraded from v8.0.0 to v8.7.5 |
CR23X 2299 | 2017-08-17 | Vaira Data Logger Met | Removed | Lab none | Removed from Vaira where it was collecting met data. It was replaced by a CR1000. |
NR-LITE 990353 | 1999-07-29 | Factory | Calibration | Factory | Initial factory calibration: 12.3 uV/W/m2. Recommend recal every two years. |
SRS-Ni NDVI 2046503344 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to E indicating a hemispherical incoming orientation and the head was labeled with sn, address, and 'out'. |
SRS-Ni NDVI 2046503376 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to E indicating a hemispherical outgoing orientation and the head was labeled with sn, address, and 'out'. |
SRS-Ni NDVI 2046503354 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to E indicating a hemispherical incoming orientation and the head was labeled with sn, address, and 'out'. |
SRS-Ni NDVI 2046503357 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to E indicating a hemispherical outgoing orientation and the head was labeled with sn, address, and 'out'. |
SRS-Ni NDVI 2046503404 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to E indicating a hemispherical outgoing orientation and the head was labeled with sn, address, and 'out'. |
SRS-Ni NDVI 1066703780 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to C indicating a hemispherical incoming orientation and the head was labeled with sn, address, and 'in'. |
SRS-Ni NDVI 2046503390 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to C indicating a hemispherical incoming orientation and the head was labeled with sn, address, and 'in'. |
SRS-Ni NDVI 1066703767 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to E indicating a hemispherical incoming orientation and the head was labeled with sn, address, and 'out'. |
SRS-Ni NDVI 2046503398 | 2017-06-04 | Lab none | Maintenance | Lab none | The SDI-12 address was set to C indicating a hemispherical incoming orientation and the head was labeled with sn, address, and 'in'. |
SRS-Ni NDVI 2046503402 | 2017-08-17 | Lab none | Installed | Vaira Narrow Band Reflected | Installed on the Vaira Tower in the outgoing position |
SRS-Ni NDVI 2046503368 | 2017-08-17 | Lab none | Installed | Vaira Narrow Band Incoming | Installed on the Vaira Tower in the incoming position. |
NR-LITE 990353 | 2017-08-17 | Vaira Net Radiometer | Removed | Lab none | Removed from the Vaira tower with the upgrade on the data logger. This sensor is redundant with the 4-way CNR1 and is very old. |
LI-7500A 75H-2514 | 2017-08-17 | Lab none | Installed | Vaira Gas Analyzer CO2/H2O | Installed on the Vaira Tower to replace sn 0035 for calibration |
LI-7500A 0035 | 2017-08-17 | Vaira Gas Analyzer CO2/H2O | Removed | Lab none | Removed from the Vaira Tower for calibration. Replaced by sn 75H-2514. |
LI-7550 AIU-1870 | 2017-08-17 | Vaira Interface LI-7550 | Upgrade | Vaira Interface LI-7550 | We upgrade the firmware from v8.5.0 to v8.75 |
LI-7550 AIU-1866 | 2017-08-17 | Tonzi-Tower | Upgrade | Tonzi-Tower | The firmware was upgraded from v8.5.0 to v8.7.5 |
LI-7500A 75H-2182 | 2017-08-17 | Lab none | Installed | Tonzi-Tower | Installed on the Tonzi Tower to replace sn 0041 for calibration |
LI-7500A 0041 | 2017-08-17 | Tonzi-Tower | Removed | Lab none | Removed from the Tonzi Tower for calibration. Replaced by sn 75H-2182 |
LI-7500A 75H-2180 | 2017-08-17 | Lab none | Installed | Tonzi-Floor | Installed on the Tonzi Floor to replace sn 0042 for calibration |
LI-7500A 0042 | 2017-08-17 | Tonzi-Floor | Removed | Lab none | Removed from the Tonzi Floor for calibration. Replaced by sn 75H-2180 |