Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Equipment and Calibration

View History

Equipment Entry

Instrument:RH & Temp
Manufacture:Vaisala
Model No:HMP45AC
Serial No:T2130005
Tag No:
Acquisition Date:2013-04-10
Project:Siyan
Location on 2020-07-09:Loaned,
Notes: Recovered from old equipment from a project of Siyans

Documents

No documents found

Report: HMP RH and AirT Comparison 12-2017 - 2017-12-18
Report: HMP155 lab and Oxford test - 2019-10-01

History

Rec No.DateLoc FromTitleLoc ToNotes
4612 2020-07-09 Loaned Disposed Disposed Given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
4582 2020-07-09 Sherman Barn RH & Temp Removed Loaned none Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
4277 2019-12-16 Lab none Installed Sherman Barn RH & Temp Installed at SB to replace sn sn U3030041, which had been removed and brought back to the lab for testing.
4187 2019-10-21 Lab none Calibration Lab none Air T calibration: y=0.94336x+0.71025, R2=0.99
RH calibration: y=1.0497x+2.8693, R2=0.99
x is the sensor output, y is the calibrated value
4186 2019-10-15 Lab none Tested Lab none Tested at Oxford Tract for a week against reference sensor HMP155 sn R0360206. See RT Report "HMP155 lab and Oxford test":
https://nature.berkeley.edu/biometlab/bmetdata/rtreport.php?screen=view&id=28

See linear regression calibration in separate equipment history entry.
3986 2019-05-22 Lab none Tested Lab none I removed the power cord and soldered on an extension cord. Tested in the lab with radiation shields and fans, and compared well with two HMP60s sn L1740398 (Campbell has OK'd this one) and sn G4540023. This sensor is probably ok, but maybe we can test it with a reference AirT/RH sensor from AMP.
3935 2019-04-24 Lab none Tested Lab none Tested overnight in the lab. This sensor has an extension cable soldered on. Didn't see any spikes, and the numbers seem reasonable. However, the control wire seems extraneous--the AirT and RH numbers seem ok even when the control wire is not connected to the datalogger, even though the sensor still has the power control board. More testing needed before we deploy it.
3852 2019-01-24 Sherman Wetland RH & Temp Removed Lab none Brought back to the lab from SW for inspection b/c of data drops/spikes. It was replaced by sn W0730036.
3683 2018-08-23 Lab none Installed Sherman Wetland RH & Temp Installed at SW to replace the other HMP45 with a too short cable. Mounted in the original location. 1% slope in T and 6% slope in RH from TA inter-comparison.
3257 2017-12-19 Twitchell Alfalfa Removed Lab none Removed from the HMP inter-comparison at Twitchell Alfalfa
3272 2017-12-18 Lab none Installed Twitchell Alfalfa Installed at Twitchell Alfalfa for an inter-comparison of HMPs
2816 2017-06-01 Tonzi-Tower Removed Lab none Removed from the higher middle position of CO2 profile system on the Tonzi Tower. At least one has not been working and all need to be compared against each other for drift.
970 2013-04-19 Lab none Installed Tonzi-Tower Installed on the Tonzi tower at the 2nd from top (6.0m) CO2 profile inlet location. Wired to the AM16/32 multiplexor connected to the tower top CR23X
 
 

Login