Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2018-01-11 11:00:00 | 2018-01-31 11:55:00-->
Other sites visited today: Twitchell Alfalfa | East End | West Pond | Sherman Wetland | Mayberry | Bouldin Alfalfa

Bouldin Corn: 2018-01-16 12:35:00 (DOY 16)
Author: Daphne Szutu
Others: Dennis, Kyle, Sam

Summary: Regular data collection/cleaning, re-installed 7500 on temporary mount

2018-01-16
Bouldin Corn

We arrived at 12:35. It was cool and overcast with a light breeze. The field is flooded and the ground by the tower is squishy. All of Tyler and Heather's chambers are off the field and on top of the blue box.

Kyle refilled the wash reservoir; it was 1/2 empty. Dennis cleaned the rad and flux sensors. There has been no 7500 here because the previous one had a PLL chopper error. We forgot to bring the 7500 Licor mount and did not initially install the replacement 7500.

I collected met, camera, and USB GHG data. AirT was too high, ~37 deg C. SHF plates were all NAN. Kyle checked the connection between the HMP sensor and the cable; it looked fine. After he reconnected the cable, AirT seemed reasonable, ~10 deg C, and SHF plates were non NAN. VWC3 has been reading 7999 in and out, but seems ok now. We should keep an eye on these measurements.

LI-7500 readings:
CO2 (no sensor)
H2O (no sensor)
T 12.3 C
P 102.2 kPa
SS (no sensor)

LI7700 readings:
CH4 2.2 ppm
RSSI 60 --> 70 after cleaning

We left at 13:05.

We came back at 13:50. Kyle and Sam attached LI-7500 sn 0035 with electrical tape and zip ties to the 7500 post; the top of the post is next to the open path, so the air flow through the sensor is slightly blocked. Next time we will bring the 7500 Licor mount and bird spikes to install the sensor properly. I uploaded the configuration file, updated the pressure coeff, and reset the 7550 interface box.

LI-7500 readings:
CO2 435 ppm
H2O 555 ppm
T 13.12 C
P 101.8 kPa
SS 100

We left again at 14:10.

Note: compare diffuse to Rgin.

1 photos found

Temporary mount for 7550 because we forgot the Licor mount.
20180116BC_7550TempMount.jpg ( 2018-01-16 14:03:25 ) Full size: 480x640
Temporary mount for 7550 because we forgot the Licor mount.

Graphs display:
6 sets found

17 BC_met graphs found

Battery Voltage

Soil Heat Flux

Temperature

Solar Radiation

Air Pressure and RH

Soil Moisture

Bouldin Corn PAR

NDVI channels

PRI Channels

Soil Temperatures Set A

Soil Temperatures Set B

Soil Temperatures Set C

SRS NDVI and PRI

Surface Temperature

Forced Diffusion CO2

Forced Diffusion Soil CO2 Flux

Surface Temperature

5 BC_flux graphs found

LI-7500 CO2 and H2O

7700 CH4 and RSSI

Wind

Counts

CO2 in ppm

Can't check TATWBABCSB_cam
Can't check MBSWEEWPBCBA
No data found for BC_pa.
No data found for BC_arable.

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.