Equipment and Calibration History

Page: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 [24] 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70
Ser No.DateLoc FromTitleLoc ToNotes
LI-7500A 0418 2002-08-15 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 0042 for calibration.
LI-7500A 0042 2002-08-15 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0418.
LI-7500A 0035 2002-08-15 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi-Tower to replace sn 0041 for calibration.
LI-7500A 0041 2002-08-15 Tonzi-Tower Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Tower for calibration. Replaced by sn 0035.
LI-7500A 0073 2002-08-15 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0065 for calibration.
LI-7500A 0065 2002-08-15 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0073.
eosFD FD20190028 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection and repair
eosFD FD20190028 2020-09-28 Lab none Tested Lab none No pump sounds (orange light inside comes on) and both CO2 channels read the same. The flux is zero. Probably dead pump. I'm tempted to take this one apart and look for a loose wire but it's less than a year old and I don't want to void any warranty.
eosFD FD20160001 2020-10-08 Lab none Shipped Factory none Sent to Eosense for evaluation and repair.
eosFD FD20160001 2020-09-28 Lab none Tested Lab none The pump is running but both CO2 signals are
just noise. Probably another dead IRGA. Also there's a scratch in oneof the atmospheric diffusion membranes.
GP-001 GP20150101 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20140016 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20160069 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20160096 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20140017 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20140019 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20150109 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20140018 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection
GP-001 GP20140088 2020-10-08 Lab none Shipped Factory none Sent to Eosense for inspection. No record of this sensor ever being used in the field but it was in the pile of bad sensors.
GP-001 GP20160096 2020-10-05 East End CO2 probe Removed Lab none Removed from EE because it still rails high in air and in water. Will send it back to the factory
BB-Fab BB-EE 2020-10-05 East End Battery Bank Replaced East End Battery Bank Replaced old battery bank with 4 brand-new sealed AGM batteries. The terminals have been sprayed with anti-corrosion grease.
GP-001 GP20160096 2019-10-02 Lab none Installed East End CO2 probe Installed at EE off the north side of the tower.
LI-7500A 0042 2002-07-19 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 0073 for calibration.
LI-7500A 0073 2002-07-19 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0042.
LI-7500A 0041 2002-07-11 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi-Tower to replace sn 0035 for calibration.
LI-7500A 0035 2002-07-11 Tonzi-Tower Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Tower for calibration. Replaced by sn 0041.
LI-7500A 0065 2002-07-11 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0042 for calibration.
LI-7500A 0042 2002-07-11 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0065.
LI-7500A 0073 2002-06-20 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 0065 for calibration.
LI-7500A 0065 2002-06-20 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0073.
LI-7500A 0073 2002-05-09 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0035 for calibration.
LI-7500A 0035 2002-05-09 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0073.
LI-7500A 0065 2002-05-09 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 0042 for calibration.
LI-7500A 0042 2002-05-09 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0065.
LI-7500A 0042 2002-04-18 Vaira Gas Analyzer CO2/H2O Location Vaira Gas Analyzer CO2/H2O Tried to swap out for calibration but replacement (sn 0073) was reading out of range. Left in place
WMP 1352 000028 2002-04-18 Vaira Anemometer Location Vaira Anemometer Location noted in fieldnotes
WMP 1352 000022 2002-04-18 Tonzi-Tower Anemometer Tower Location Tonzi-Tower Anemometer Tower Location noted in fieldnotes
LI-7500A 0041 2002-04-18 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi/Vaira to replace sn 0065 for calibration.
LI-7500A 0065 2002-04-18 Tonzi-Tower Gas Analyzer CO2/H2O Removed Lab none Removed from Bouldin Alfalfa for calibration. Replaced by sn 0041.
LI-7500A 0035 2002-04-18 Tonzi-Floor Gas Analyzer CO2/H2O Location Tonzi-Floor Gas Analyzer CO2/H2O Location noted in fieldnotes
WMP 1352 000021 2002-04-18 Tonzi-Floor Anemometer Floor Location Tonzi-Floor Anemometer Floor Location noted in fieldnotes
eosFD FD20180047 2020-10-05 Lab none Installed Bouldin Alfalfa Forced Diffusion A Installed at Bouldin Alfalfa replacing sn FD20180048 that has low CO2 concentration readings. Also added a relay to restart this chamber at midnight to avoid high temperature start up problem.
eosFD FD20180048 2020-10-05 Bouldin Alfalfa Forced Diffusion A Removed Lab none Removed from Bouldin Alfalfa to check on it's low CO2 concentration readings. Replaced by sn FD20180047
WMP 1352 000028 2002-04-11 Loaned none Installed Vaira Anemometer Installed at Vaira to replace sn 000024 for calibration.
WMP 1352 000024 2002-04-11 Vaira Anemometer Removed Lab none Removed from Vaira for calibration. Replaced by sn 000028.
WMP 1352 000022 2002-04-11 Lab none Installed Tonzi-Tower Anemometer Tower Installed at Tonzi-Tower to replace sn 000020 for calibration.
WMP 1352 000020 2002-04-11 Tonzi-Tower Anemometer Tower Removed Lab none Removed from Tonzi-Tower for calibration. Replaced by sn 000022.
LI-7500A 0035 2002-04-11 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0073 for calibration.
LI-7500A 0073 2002-04-11 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0035.
LI-7500A 0035 2002-02-28 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 0065 for calibration.
LI-7500A 0065 2002-02-28 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0035.
LI-7500A 0042 2002-02-28 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0041 for calibration.
LI-7500A 0041 2002-02-28 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0042.
BB-Fab BB-TT 2002-01-23 Tonzi-Tower Battery Bank Upgrade Tonzi-Tower Battery Bank Added two new deep cycle batteries the to existing two batteries
BB-Fab BB-TF 2002-01-23 Tonzi-Floor Battery Bank Upgrade Tonzi-Floor Battery Bank Added two new deep cycle batteries the to existing two batteries
HMP45AC W0730037 2002-06-06 Lab none Installed Vaira RH & Temp Installed at Vaira to replace sn U3030046 for calibration.
HMP45AC U3030046 2002-06-06 Vaira RH & Temp Removed Lab none Removed from Vaira for calibration. Replaced by sn W0730037.
LI-7500A 0035 2002-06-06 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi-Tower to replace sn 0041 for calibration.
LI-7500A 0042 2002-06-06 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0073 for calibration.
LI-7500A 0073 2002-06-06 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0042.
LI-7500A 0035 2002-11-05 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi-Tower to replace sn 0041 for calibration.
LI-7500A 0041 2002-11-05 Tonzi-Tower Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Tower for calibration. Replaced by sn 0035.
LI-7500A 0073 2002-11-05 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 0065 for calibration.
LI-7500A 0065 2002-11-05 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0073.
LI-7500A 0418 2002-11-05 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 0042 for calibration.
LI-7500A 0042 2002-11-05 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0418.
PAR-LITE 990031 2020-09-29 Vaira PAR Sensor Reflected Cal Removed Lab none Removed from the tower (reflected cal) for repair - the cable is all rotted
PAR-LITE 990025 2020-09-29 Vaira PAR Sensor Incoming Cal Removed Lab none Removed from the tower (incoming cal) for repair - the cable is all rotted
PAR-LITE 990025 2020-09-16 Vaira PAR Sensor Incoming Moved Vaira PAR Sensor Incoming Cal Moved from the main incoming position to the incoming cal position in preparation to being removed.
PAR-LITE 040412 2020-09-16 Vaira PAR Sensor Incoming Cal Moved Vaira PAR Sensor Incoming Moved from the incoming cal position to the main incoming position.
PAR-LITE 990031 2020-09-16 Vaira PAR Sensor Reflected Moved Vaira PAR Sensor Reflected Cal Moved from the main reflected position to the reflected cal position in preparation to being removed.
PAR-LITE 030381 2020-09-16 Vaira PAR Sensor Reflected Cal Moved Vaira PAR Sensor Reflected Moved from the reflected cal position to the main reflected position.
BB-Fab BB-VR_soilco2 2020-09-16 Vaira Battery Bank SoilCO2 Maintenance Vaira Battery Bank SoilCO2 I checked the water in the soil co2 battery bank. The water levels were low exposing the plates but these batteries didn’t take that much water – about a gallon to fill all of them.
BB-Fab BB-EE 2020-09-29 East End Battery Bank Maintenance East End Battery Bank Five remaining batteries disconnected and left resting for most of the day. Water levels were okay but all tested weak to dead. The system is running on one new battery for the time being.
eosFD FD20180067 2020-09-01 Bouldin Corn Forced Diffusion C Moved Bouldin Corn Forced Diffusion C Moved tower and soil sensors back from field in preparation for corn harvest. Chambers were reinstalled under the tower.
eosFD FD20180048 2020-09-01 Bouldin Corn Forced Diffusion B Moved Bouldin Corn Forced Diffusion B Moved tower and soil sensors back from field in preparation for corn harvest. Chambers were reinstalled under the tower.
HFP01 10861 2020-09-01 Bouldin Corn Heat Flux Plate C Moved Bouldin Corn Heat Flux Plate C Moved tower and soil sensors back from field in preparation for corn harvest. Soil sensors were reinstalled under the tower at -2cm depth.
HFP01 10867 2020-09-01 Bouldin Corn Heat Flux Plate B Moved Bouldin Corn Heat Flux Plate B Moved tower and soil sensors back from field in preparation for corn harvest. Soil sensors were reinstalled under the tower at -2cm depth.
HFP01 11326 2020-09-01 Bouldin Corn Heat Flux Plate A Moved Bouldin Corn Heat Flux Plate A Moved tower and soil sensors back from field in preparation for corn harvest. Soil sensors were reinstalled under the tower at -2cm depth.
CS451 70011234 2020-09-01 Bouldin Corn Water Level Moved Bouldin Corn none Moved tower and soil sensors back from field in preparation for corn harvest. Joe dug a new well east of the tower for the water level sensor. Sensor is 69 cm below ground.
Top of pipe to ground = 58 cm
Top of pipe to sensor = 127 cm
Well depth ~ 160 cm (dry at bottom)
CS655 17129 2020-09-01 Bouldin Corn Soil Moisture Probe A Moved Bouldin Corn Soil Moisture Probe A Moved tower and soil sensors back from field in preparation for corn harvest. Soil sensors were reinstalled under the tower at -2cm depth.
CS655 17128 2020-09-01 Bouldin Corn Soil Moisture Probe B Moved Bouldin Corn Soil Moisture Probe B Moved tower and soil sensors back from field in preparation for corn harvest. Soil sensors were reinstalled under the tower at -2cm depth.
CS655 17133 2020-09-01 Bouldin Corn Soil Moisture Probe C Moved Bouldin Corn Soil Moisture Probe C Moved tower and soil sensors back from field in preparation for corn harvest. Soil sensors were reinstalled under the tower at -2cm depth.
ML3 M003370 2020-09-01 Bouldin Corn Soil Moisture Probe Theta Moved Bouldin Corn Soil Moisture Probe Theta Moved tower and soil sensors back from field in preparation for corn harvest. The theta probe was reinstalled vertically under the tower.
HFP01 10861 2020-05-19 Bouldin Corn Heat Flux Plate C Moved Bouldin Corn Heat Flux Plate C Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
HFP01 10867 2020-05-19 Bouldin Corn Heat Flux Plate B Moved Bouldin Corn Heat Flux Plate B Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
HFP01 11326 2020-05-19 Bouldin Corn Heat Flux Plate A Moved Bouldin Corn Heat Flux Plate A Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
CS655 17129 2020-05-19 Bouldin Corn Soil Moisture Probe A Moved Bouldin Corn Soil Moisture Probe A Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
CS655 17128 2020-05-19 Bouldin Corn Soil Moisture Probe B Moved Bouldin Corn Soil Moisture Probe B Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
CS655 17133 2020-05-19 Bouldin Corn Soil Moisture Probe C Moved Bouldin Corn Soil Moisture Probe C Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
ML3 M003370 2020-05-19 Bouldin Corn Soil Moisture Probe Theta Moved Bouldin Corn Soil Moisture Probe Theta Moved back into the field from being under the scaffolding at the side of the field for tilling and planting.
eosFD FD20160001 2020-09-23 Bouldin Alfalfa Forced Diffusion A Removed Lab none Removed from BA and brought back to the lab for testing because of noisy data. It was replaced by sn FD20180048.
eosFD FD20190028 2020-09-23 Bouldin Alfalfa Forced Diffusion B Removed Lab none Removed from BA and brought back to the lab for testing because of noisy data
PA-II-SD 68c63acc07a9 2020-09-23 Lab none Installed Bouldin Corn Air Quality Sensor Installed at BC to replace sn 84f3ebd5ffb1, which was brought back to the lab for testing
PA-II-SD 84f3ebd5ffb1 2020-09-23 Bouldin Corn Air Quality Sensor Removed Lab none Removed from BC and brought back to the lab for testing because it does not consistently have files on the card
eosFD FD20180047 2020-09-23 Bouldin Corn Forced Diffusion A Removed Lab none Removed and brought back to the lab for testing because it would not connect in the field
eosFD FD20180048 2020-09-23 Bouldin Corn Forced Diffusion B Moved Bouldin Alfalfa Forced Diffusion A Moved from BC to BA to replace sn FD20160001, which was brought back to the lab for testing
LI-7500A 0042 2001-11-10 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Tonzi to replace sn 0041 for calibration.
LI-7500A 0041 2001-11-10 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Tower for calibration. Replaced by sn 0042.
LI-7500A 0065 2001-08-17 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi-Tower to replace sn 0042 for calibration.