Field Notes
<--2020-01-23 10:00:00 |Other sites visited today: Mayberry | Sherman Wetland
Phenocam link: Searching...
East Pond: 2020-01-30 09:30:00 (DOY 30)
Author: Joe Verfaillie
Others: Dennis, Alex, Robert, Daphne
Summary: Decommissioning of the site. All sensors and equipment removed and taken to Sherman Wetland.
East Pond 2020-01-30 Dennis, Alex, Robert and I arrived at about 9:30. It was mostly sunny and cool. The wetlands all are very brown. Dennis was very surprised with how much East End had been blown down. Today is the last day for the East Pond tower. We are taking it down and moving it to Sherman Wetland. I decided to wait to collect data as the others were itching to start taking things apart. I shutdown the Pi-cam and then turned off the power and started taking the solar system apart. Alex and Robert made a bunch of sensor location measurements before starting to disassemble things. Dennis cursed a lot. Everything went relatively well. The soil/water sensors were heavily over grown with vegetation and hard to get out. One heat flux plate sn 00244 was lost when its cable broke off right at the plate. Daphne arrive at about 10:45 and helped to finish up and pack. We left at about noon time. Equipment removed WM 1590: sn 153803 LI-7700: sn TG1-0211 LI-7500A: sn 0041 LI-7550: sn AIU-0650 PTB110: sn H0160093 CR1000: sn 50889 AM16/32A: sn 1164 AM25T: sn 2856 miniDOT-usb: sn 931528 HFP (A north): sn 00244 Lost HFP (B west): sn 00245 HFP (C south): sn 10809 Campbell TDR: sn 17130 Campbell TDR: sn 17131 SRS-Ni NDVI: sn 2046503368 SRS-Ni NDVI: sn 2046503402 CNR1: sn 990181 PAR-LITE: sn 050596 PAR-LITE: sn 050597 HMP60: sn G4540021 Water Level CS450: sn 20010770 PS-30M: sn 11400080 Battery Bank: sn BB-EP Solar Panel: sn 11ZV0M0829 Solar Panel: sn 11ZV0M0836 Solar Panel: sn 11ZV0M0855 Pi-cam Some sensor location measurements Sonic orientation = 0 deg magnetic 7500-sonic distance = 30cm 7500-sonic orientation = 80 deg 7700-sonic distance = 25cm 7700-sonic orientation = 120 deg Flux sensor height from water surface = 5.62m Flux sensor height from ground surface = 5.74m Veg height = ~1.5m very heterogeneous Staff gauge water level = reading 46cm with 14cm of water above the muck Top of well to water surface = 40.5cm Top of well to soil surface = 47.5cm Top of well to water level sensor = 1.46m |
0 photos found
5 sets found
Can't check MBEEWPSWEPGT_cam
9 EP_met graphs found
4 EP_flux graphs found
Can't check EP_hobo
1 EP_hobo graphs found
Can't check EP_level1
3 EP_level1 graphs found