Equipment and Calibration History

Page: 1 2 3 4 5 6 7 8 9 10 11 12 [13] 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70
Ser No.DateLoc FromTitleLoc ToNotes
LI-7500A 75H-2180 2022-08-31 Lab none Installed Bouldin Corn Gas Analyzer CO2/H2O Installed at Bouldin Corn to replace sn 0065 for calibration.
LI-7500A 0065 2022-08-31 Bouldin Corn Gas Analyzer CO2/H2O Removed Lab none Removed from Bouldin Corn for calibration. Replaced by sn 75H-2180.
LI-7500A 75H-2180 2022-08-30 Mayberry Gas Analyzer CO2/H2O Removed Lab none Removed from MB and brought back to the lab for calibration. It was replaced by sn 75H-2514.
LI-7500A 75H-2514 2022-08-30 Lab none Installed Mayberry Gas Analyzer CO2/H2O Installed at Mayberry to replace sn 75H-2180 for calibration.
S2-411 1054 2022-08-30 East End Narrow Band NDVI Reflected B Removed Lab none Removed from EE and brought back to the lab for testing. 650out data is bad.
S2-411 1053 2022-08-30 East End Narrow Band NDVI Incoming B Removed Lab none Removed from EE and brought back to the lab for testing. This sensor's data was ok but the outgoing(reflected) sensor sn 1054 data was weird, so I brought both sensors in.
RPI0W RPI0W-001 2022-06-08 Bouldin Corn camera B Removed Disposed none This camera was dead. There was a puddle of water in the bottom of the enclosure and white corrosion all over the board and mini-USB connector.
RPI0W RPI0W-002 2022-05-27 Lab none Installed Bouldin Corn Camera C Installed between corn rows
RPI0W RPI0W-001 2022-05-27 Lab none Installed Bouldin Corn camera B Installed in line with a corn row.
LI-7500A 75H-2180 2022-08-30 Lab Calibration Lab Last calibration: 2022-03-30
AGC=100.2 SDM= DAC1= DAC2=
Ambient P=100.5kPa, Tair=24.8C, Tdew=14.4C
Zero Air at 275psi, AMP CA04119 524.77 at 1400 Tdewspan=20.00
CO2 zero 0.9141 -> 0.9148 Offset: 3.30ppm
CO2 span 1.0373 -> 1.0318 Offset: 3.89ppm
H2O zero 0.8911 -> .8916 Offset: 3.3ppm
H2O span 1.0345 -> 1.0122 Offset: .49ppm
Notes: The initial H2O Span at 20.00 made the sensor jump to 20.02, but another span a few minutes later was right on 20.00. Should be ok.
SD130BN 0030F4D214A4 2022-08-29 Lab none Shipped Factory none Shipped back to StarDot for inspection/repair. The green LED in front comes on when the camera is plugged into power, but there is no network activity no matter how I try to physically connect it (through a router, through a switch, directly through a computer; with every combination of laptop ethernet port IP address/subnet). The only exception is if I connect it directly to a laptop with a crossover cable--the camera ethernet port does have a green light blinks every 3 seconds, but there are no changes to the green light (i.e., no network activity) even when I start StarDot Tools. It seemed to boot fine after a hard reset, but there was still no network activity. This camera was set to the default 192.168.2.101 IP address and connected fine in the lab in the past. The camera stopped working after bringing it back from Elkhorn Slough field trip in mid July.
LI-7500A 75H-2182 2022-08-24 Lab none Shipped Factory none Shipped back to Licor for inspection and repair. Expected turnaround time is 2-3 months.
LI-7500A 75H-2176 2022-08-24 Lab none Installed Hill Slough Gas Analyzer CO2/H2O Installed at Hill Slough to replace sn 0035 for calibration.
LI-7500A 0035 2022-08-24 Hill Slough Gas Analyzer CO2/H2O Removed Lab none Removed from Hill Slough for calibration. Replaced by sn 75H-2176.
CR23X 2299 2022-08-24 Lab none Installed Hill Slough none Installed with a solar panel and lithium battery at the Hill Slough channel. This datalogger will collect data from water sensors installed in the channel.
LI-7500A 0035 2022-08-25 Lab none Installed Tonzi-Floor Gas Analyzer CO2/H2O Installed at Tonzi-Floor to replace sn 75H-2514 for calibration
BB-Fab BB-TZ_soilco2 2022-08-25 Tonzi Battery Bank soil co2 Maintenance Tonzi Battery Bank soil co2 This battery bank had been without batteries since its batteries were moved to the Tower a few weeks ago. I installed three old batteries from the Floor system that tested ok with the load tester. I rewired the two larger solar panels to 12V. The two smaller panels had there leads chewed and I left them disconnected for now.
LI-7500A 75H-2514 2022-08-25 Tonzi-Floor Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Floor for calibration. Replaced by sn 0035.
LI-7500A 75H-2669 2022-08-25 Lab none Installed Tonzi-Tower Gas Analyzer CO2/H2O Installed at Tonzi-Tower to replace sn 0418 for calibration.
LI-7500A 0418 2022-08-25 Tonzi-Tower Gas Analyzer CO2/H2O Removed Lab none Removed from Tonzi-Tower for calibration. Replaced by sn 75H-2669.
BB-Fab BB-TF 2022-08-25 Tonzi-Floor Battery Bank Maintenance Tonzi-Floor Battery Bank The four existing batteries have been dying as soon as it gets dark. These were replaced with the four good batteries from the Tower installed in a new action packer box. The solar panel wiring was also checked but no issues found. Three of the old batteries tested okay and were moved to the Soil CO2 system. The one old battery that tested weak with the load tester was returned for its lead.
BB-Fab BB-TT 2022-08-25 Tonzi-Tower Battery Bank Maintenance Tonzi-Tower Battery Bank Six new Duracell deep cycle AGM batteries were installed in two new action packers. Four good batteries were moved to the Floor and the rest of the 12 dead batteries turned in for their lead.
CTD-10 1782303006 2022-08-24 Gilbert Tract Removed Lab none Removed from GT and brought back to the lab. The depth data is bad but temperature and conductivity seemed reasonable.
LI-7500A 0035 2022-08-25 Lab Calibration Lab Last calibration: 2022-04-19
AGC=99.1 SDM=0 DAC1=- DAC2=-
Ambient P=100.3kPa, Tair=20.5C, Tdew=13.9C
Zero Air at 300psi, AMP CA04119 524.77 at 1400 Tdewspan=18.0
CO2 zero 0.9372 -> 0.9374 Offset: 0.7ppm
CO2 span 1.0167 -> 1.0234 Offset: -4.57ppm
H2O zero 0.8983 -> 0.8995 Offset: 7.4ppm
H2O span 1.031 -> 1.0334 Offset: -0.05ppm
Notes:
LI-7500A 75H-2669 2022-08-23 Lab Calibration Lab Last calibration: 2021-12-09
AGC=95.8 SDM= DAC1= DAC2=
Ambient P=100kPa, Tair=26.03C, Tdew=16.96C
Zero Air at 300psi, AMP CA04119 524.77 at 1400 Tdewspan=20.00
CO2 zero 0.9186 -> .9188 Offset: .94ppm
CO2 span 1.0133 -> 1.0083 Offset: 3.8ppm
H2O zero 0.9008 -> .9040 Offset: 20.6ppm
H2O span 1.0123 -> 1.0174 Offset: -.11ppm
Notes: Calibration using AMP loaner 7550 sn AIU-1039
LI-7500A 75H-2176 2022-08-23 Lab Calibration Lab Last calibration: 2022-04-19
AGC=96.3 SDM= DAC1= DAC2=
Ambient P=100.1kPa, Tair=24.01C, Tdew=14.55C
Zero Air at 300psi, AMP CA04119 524.77 at 1400 Tdewspan=20.00
CO2 zero 0.867 -> .8678 Offset: 3.56ppm
CO2 span 1.0081 -> 1.0008 Offset: 4.59ppm
H2O zero 0.8557 -> .8537 Offset: -11.9ppm
H2O span 0.9228 -> .923 Offset: -.02ppm
Notes: Calibration using AMP loaner 7550 sn AIU-1039
eosFD 20160002 2018-01-17 Lab none Returned Factory none Sent by Fedex to Gregory Maurer (UCB) currently at UNM Albuquerque for Eosense.
eosFD 20160003 2018-01-17 Lab none Returned Factory none Sent by Fedex to Gregory Maurer (UCB) currently at UNM Albuquerque for Eosense.
eosFD 20160004 2018-01-17 Lab none Returned Factory none Sent by Fedex to Gregory Maurer (UCB) currently at UNM Albuquerque for Eosense.
eosFD 20160005 2018-01-17 Lab none Returned Factory none Sent by Fedex to Gregory Maurer (UCB) currently at UNM Albuquerque for Eosense.
eosFD 20160006 2018-01-17 Lab none Returned Factory none Sent by Fedex to Gregory Maurer (UCB) currently at UNM Albuquerque for Eosense.
LI-7500A 75H-2418 2022-08-18 Lab none Installed Gilbert Tract Gas Analyzer CO2/H2O Installed on the GT tower to replace the one that failed a few days ago and was removed.
BB-Fab BB-TZ_soilco2 2022-08-05 Tonzi Battery Bank soil co2 Maintenance Tonzi Battery Bank soil co2 The batteried in this bank have been temporarily removed to power the Tower. Likely this bank will be repopulated to power the OSU-SP1 system and a couple FD chambers as the Vaisala soil CO2 system is decommissioned.
BB-Fab BB-TF 2022-08-05 Tonzi-Floor Battery Bank Maintenance Tonzi-Floor Battery Bank This bank has been failing in the early morning. I disconnected all the batteries and they load tested okay. I added three gallons of DI to the four batteries. I shouted the south most to wiring them back up but they seemed okay.
BB-Fab BB-TT 2022-08-05 Tonzi-Tower Battery Bank Maintenance Tonzi-Tower Battery Bank The batteries in this bank are completely dead - not even accepting charge at midday. These batteries were all disconnected and four batteries from the soil co2 system sn BB-TZ_soilco2 were temporarily swapped in.
LI-7500A 75H-2418 2022-08-17 Lab Calibration Lab Last calibration: 2020-03-23
AGC=100.5 SDM=0 DAC1=- DAC2=-
Ambient P=100.2kPa, Tair=24.2C, Tdew=13.6C
Zero Air at 300psi, AMP CA04119 524.77 at 1400 Tdewspan=20.0
CO2 zero -> 0.9786 Offset: -0.7ppm
CO2 span 1.0091 -> 1.0054 Offset: 2.63ppm
H2O zero 0.8245 -> 0.8242 Offset: 0.9ppm
H2O span 1.0166 -> 1.0292 Offset: -0.28ppm
Notes: Borrowed from Ameriflux. Previous cal values retrieved from instrument. Seems the 7500s don't drift much and that our cal methods match whatever methods were used last time.
S2-411 1050 2022-08-16 Lab none Installed Gilbert Tract none Installed at GT in the reflected position and data collected in a separate data table for an NDVI intercomparison.
S2-411 1049 2022-08-16 Lab none Installed Gilbert Tract none Installed at GT in the incoming position and data collected in a separate data table for an NDVI intercomparison.
LI-7500A 75H-2182 2022-08-16 Gilbert Tract Gas Analyzer CO2/H2O Removed Lab none Removed from GT because it was reading **.** and brought back to the lab for further testing.
SD130BN 0030F4D214A4 2022-03-31 Mayberry Removed Lab none Removed from Mayberry with the end of the camera inter-comparison
HFP01 003072 2022-08-04 Lab none Installed Bouldin Alfalfa-ADEX Heat Flux Plate Bouncer A Installed at the Bouncer tower at -10cm depth
SI-131 7385 2022-08-10 Lab none Installed Experiment Installed on the back of Robert's e-bike for his urban heat island transect in Oakley
LI-7500 0976 2022-08-10 Lab none Installed Experiment Installed on the back of Robert's e-bike for his urban heat island transect in Oakley
NR-LITE 990354 2022-08-10 Lab none Installed Experiment Installed on the back of Robert's e-bike for his urban heat island transect in Oakley
PAR-LITE 990025 2022-08-10 Lab none Installed Experiment none Installed on the back of Robert's e-bike for his urban heat island transect in Oakley
LI-7500 0976 2022-08-10 Lab Calibration Lab Last calibration: 2017-06-12
AGC=57 SDM=7 DAC1= DAC2=
Ambient P=100.7kPa, Tair=25.8C, Tdew=15.3C
Zero Air at 300psi, AMP CA04119 524.77 at 1425 Tdewspan=20.00
CO2 zero 0.8597 -> .8596 Offset: -.03ppm
CO2 span 1.0077 -> 1.0102 Offset: 1.82ppm
H2O zero 0.6335 -> .632 Offset: -10.5ppm
H2O span 1.031 -> 1.0138 Offset: .37ppm
Notes: Pulled out this old IRGA for Robert's UHI transect via ebike. The calibration was surprisingly good given we haven't used this sensor in 5 years. Calibrated using a small white eePC netbook using a Licor serial cable that plugs directly into the green terminal block inside the box. I had to set the span temperature in software to 19.91 in order for dew point value to be 20.00 after pressing "Span".
TEROS21 G20007096 2022-06-07 Lab none Installed Tonzi Soil Water Potential C Installed near the OSU-SP1 soil sensors at -10cm, vertical orientation
SoilVUE10 2688 2022-06-07 Lab none Installed Tonzi Soil Moisture Probe J Profile Installed near the OSU-SP1 soil sensors. This is SoilVue C in the data.
SoilVUE10 2674 2022-06-07 Lab none Installed Tonzi Soil Moisture Probe I Profile I installed this probe to the west of the Floor met boxes near the existing Moisture Point probe and soil matrix sensor under the trees. This is SoilVue A in the data.
SoilVUE10 2676 2022-06-07 Lab none Installed Tonzi Soil Moisture Probe H Profile I installed this probe in the open to the south of the Floor met boxes towards the Tower along the existing power conduit. I cut a hole in the conduit and ran the cable back to the Floor CR23x. This is SoilVue B in the data.
eosFD FD20190027 2022-08-03 Lab none Tested Lab none I did two performance tests on this chamber. The CO2 for bother chambers is reading negative -200 to -300 ppm. I tried to reset it to 400ppm but it didn't seem to work.
eosFD FD20190027 2022-07-19 Tonzi-SoilCO2 Forced Diffusion Open Removed Lab none It was reading mostly zeros (with large positive and negative spikes) in the last few weeks, so it was removed and brought back to the lab for testing.
eosFD FD20180048 2022-04-27 Lab none Installed Tonzi-SoilCO2 Forced Diffusion Open Reinstalled at Tree 1 after testing in the lab. I had removed it because I thought it was broken but it might have been reading funny because it was lying on its side. It seemed okay in the lab. I installed it in a slightly different location with more litter on the soil surface.
TEROS21 G20010035 2022-04-27 Lab none Installed Tonzi Soil Water Potential B Installed near the base of a tree near the Tower Moisture Point Probe
TEROS21 G20007112 2022-04-27 Lab none Installed Tonzi Water Potential A Installed near the drip line of the trees near the Tower Moisture Point probe
EXO2 22C103416 2022-07-13 Lab none Installed Hill Slough Water Level Installed at HS in the channel off of the boardwalk, about 30m east of the tower. We installed the sonde near low tide to ensure it would stay underwater at all times.
eosFD FD20180067 2022-07-14 Lab none Installed Bouldin Corn Forced Diffusion C Installed in the corn at BC. It's in the same location from where it was removed, one row west of the zcam. I connected to the FD chamber to confirm that it was running.
NL115 13056 2022-07-14 Lab none Installed Bouldin Corn Interface NL115 Installed on the BC met CR1000 to replace sn 6761, which was brought back to the lab for testing.
NL115 6761 2022-07-14 Bouldin Corn Interface NL115 Removed Lab none Removed from BC and brought back to the lab for testing. The bottom 1/2-1/3 of phenocam photos is gray. Could be an interface or a card problem. It was replaced by sn 13056.
HFP01 003072 2022-07-14 Bouldin Alfalfa-ADEX Heat Flux Plate Bouncer A Removed Lab none Removed from the BA Bouncer tower because the cable was cut. I will repair it in the lab before we install it again.
WM 1590 153805 2022-07-31 Lab none Tested Lab none Tested the sonic and its cable in the lab with Joe's help over e-mail. Both tested fine. I mated the sonic cable with an Eosense cable and used the conductivity setting on the voltmeter to find the 4 eosense wires that corresponded to outputs 1-4. At rest (while I was standing still next to the sonic), the voltages were around +/- 8mV. I then used a fan to test U, V, W. The voltages went up to around 150mV. Placing the fan on the opposite side of the sonic produced about the same magnitude voltage with the opposite sign. SOS (output 4) was around 1.7V and didn't change much with the fan, as expected. I wired the Eosense cable to a CR1000 with a NL115 and ran it overnight, storing 30min and 20Hz data on an 8gb card. The data the next morning seemed reasonable. SOS had the same pattern as PanelT.

Sonic pin -> Licor color -> Eosense cable
8 (Output 1) -> white -> brown
14 (Output 2) -> green -> white
9 (Output 3) -> grey -> pink
15 (Output 4) -> blue -> black
10 (Analog G) -> red -> grey
16 (Analog G) -> pink -> yellow
17 (Analog G) -> yellow/brown -> blue
WM 1590 153805 2022-08-01 Lab none Installed Mayberry Anemometer Installed on MB after testing in the lab. Sonic heading = 10 deg true N.
LI-7700 TG1-0223 2022-06-08 Lab none Installed Mayberry Gas Analyzer CH4 Installed at MB after attaching a new fuse holder and fuse. This sensor was calibrated in the lab yesterday.
WM 1590 153805 2022-07-26 Mayberry Anemometer Removed Lab none Removed from MB tower for inspection back at the lab. The sonic heading was 7 deg true N before removal.
LI-7700 TG1-0421 2022-07-15 Lab none Loaned Loaned none Installed on the BWW urban tower and updated the GHG columns. I also connected the HMP back to the 7700 auxiliary input. However, I couldn't remember the correct coefficients for the HMP. I tried the same multiplier and offset we use for CRBasic, but that didn't produce reasonable data. I e-mailed Joe for help and he fixed it the following day.

This sensor still needs a wash box and wash power cable. These will have to come from BA after our next visit. The current wash tubing is a spliced one, so I could also replace that with new black tubing.
LI-6400 PSC-0785 2019-06-03 Lab none Loaned Loaned none Loaned to Yvonne Socolar. Other material loaned:
-10 cartridges
-Box of spare parts
-Two 12V Battery
LI-6400 PSC-0785 2022-07-20 Lab none Loaned Loaned none Loaned to Rizwan Rasheed from Ellen Simms' lab for the summer. Other items loaned: 2 9Ah batteries and a 12V power cord. They had originally borrowed Dave Ackerly's 6400 but we couldn't get it to turn on (display remained off).
LI-7700 TG1-0421 2022-06-01 Factory Calibration Factory Calibration Location: Factory
Last calibration: 2021-11-30
RSSI=0%, Optical RH=0%
Ambient P=0kPa, Tair=0C
0 at 0psi, 0 0 at 0
CH4 Zero Offset: 10.1875ppm
CH4 Span Offset: .000103546ppm
Notes: Calibrated at Licor factory after replacing fuse holder and fuse. Not sure of the offset units (but probably not in ppm?)
LI-7700 TG1-0421 2022-07-05 Factory none Returned Lab none Received back in the lab after repair and calibration at Licor. They replaced the fuse and fuse holder and calibrated the instrument.
LI-7700 TG1-0421 2022-04-28 Lab none Shipped Factory none Sent back to Licor for inspection/repair around this date.
eosFD FD20180067 2022-07-11 Lab none Tested Lab none Plugged in and tested in the lab with another eosense cable. The chamber seems to be fine and the clock was still accurate, so I downloaded data from 2022-05-11 to 2022-06-08. I also ran a performance check which looked fine. I did not reset the reference.
Average Flux: -0.2, 0.05 STDEV
Average ATM: 687.6ppm, 29.6C
Average Soil: 677.7ppm, 29.8C
eosFD FD20180067 2022-06-08 Bouldin Corn Forced Diffusion C Removed Lab none Removed from field and brought back to the lab because even though the pump sounds like it's working, we haven't been able to connect to it for the past month
NL115 6761 2022-06-09 Lab none Installed Bouldin Corn Interface NL115 Installed on met CR1000 at BC and connected to Stardot phenocam
eosFD FD20180067 2022-02-17 Lab none Installed Bouldin Corn Forced Diffusion C Installed at BC under the tower
BB-Fab BB-HS 2022-04-20 Hill Slough Battery Bank Maintenance Hill Slough Battery Bank There has been some power losses a couple weeks ago but okay for the last two weeks. All the screw terminals seemed tight. One of the battery terminals had some corrosion - all the terminals should be cleaned and sealed before winter.
BB-Fab BB-HS 2021-03-11 Sherman Wetland-Temp1 Battery Bank Installed Hill Slough Battery Bank We put the battery box from SW on the west side of the platform and installed the five group 31 flooded batteries from the SW temporary tower. The solar controller sn 11400080 and breakers from the SW temporary site were also installed in the battery box. The wiring is not optimal and should be cleaned up. Also because the drill battery died we could not mount the solar controller or bolt the battery box to the platform.
NR01 1454 2011-02-03 Factory none Calibration Factory none Initial factory calibration: Pyranometer Up (mn SR01 sn 1957) 15.3uV/Wm-2, Pyranometer Down (mn SR01 sn 1958) 13.6uV/Wm-2, Pyrgeometer Up (mn IR01 sn 1946) 9.0uV/Wm-2. Pyrgeometer Down (mn IR01 sn 1947) 9.4uV/Wm-2.
LI-7700 TG1-0155 2022-06-09 West Pond Calibration West Pond Calibration Location: West Pond
Last calibration: 2021-12-06
RSSI=90%, Optical RH=3%
Ambient P=101.1kPa, Tair=30.1C
Zero Air at 400psi, AMP CA04119 4.2238 at 1550
CH4 Zero Offset: .016ppm
CH4 Span Offset: .0028ppm
Notes: Hot but relatively still at this site
LI-7700 TG1-0211 2022-06-08 Hill Slough Calibration Hill Slough Calibration Location: Hill Slough
Last calibration: 2021-12-01
RSSI=73%, Optical RH=21%
Ambient P=100.7kPa, Tair=24.0C
Zero Air at 550psi, AMP CA04119 4.2238 at 1525
CH4 Zero Offset: -.002ppm
CH4 Span Offset: .0008ppm
Notes: Very windy day of course. Did not change drierite or flush headspace with zero air. Changed the top/bottom heater to start at 18:00 instead of at 16:00 for summertime.
LI-7700 TG1-0357 2022-06-08 Bouldin Corn Calibration Bouldin Corn Calibration Location: Bouldin Corn
Last calibration: 2021-12-01
RSSI=77%, Optical RH=16%
Ambient P=101kPa, Tair=28C
Zero Air at 600psi, AMP CA04119 4.2238 at 1600
CH4 Zero Offset: -.074ppm
CH4 Span Offset: .0078ppm
Notes: Extra windy day of course. Did not change drierite or flush headspace with zero air.
LI-7700 TG1-0424 2022-06-09 Gilbert Tract Calibration Gilbert Tract Calibration Location: Gilbert Tract
Last calibration: 2021-11-30
RSSI=74%, Optical RH=16%
Ambient P=101kPa, Tair=21.6C
Zero Air at 450psi, AMP CA04119 4.2238 at 1450
CH4 Zero Offset: -.01ppm
CH4 Span Offset: .0698ppm
Notes: Breezy day. Did not change drierite or flush headspace with zero air.
LI-7700 TG1-0423 2022-06-09 East End Calibration East End Calibration Location: East End
Last calibration: 2021-12-01
RSSI=70%, Optical RH=17%
Ambient P=101kPa, Tair=29.5C
Zero Air at 350psi, AMP CA04119 4.2238 at 1550
CH4 Zero Offset: .015ppm
CH4 Span Offset: -.0098ppm
Notes: Hot day, some breeze. Did not change drierite or flush headspace with zero air.
TS01 TS01-002 2022-06-07 Tonzi Removed Lab none Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed
SI-121 1624 2022-06-07 Tonzi Infrared Temperature Ref Panel B Removed Lab none Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed
SI-131 7638 2022-06-07 Tonzi Removed Lab none Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed
SI-131 7385 2022-06-07 Tonzi Infrared Temperature Grass B Removed Lab none Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed
CR10X 47772 2022-06-07 Tonzi Removed Lab none Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed
CR23X 2143 2022-06-07 Tonzi none Removed Lab none Disconnected and packed up on 05/26 but brought back to the lab today - no longer needed
LI-7700 TG1-0223 2022-06-07 Lab none Calibration Lab none Calibration Location: Lab
Last calibration: 2021-12-03
RSSI=76%, Optical RH=29%
Ambient P=100.0kPa, Tair=21.7C
Zero Air at 625psi, AMP CA04119 4.2238 at 1600
CH4 Zero Offset: -.037ppm
CH4 Span Offset: .0392ppm
Notes: Before this calibration, I replaced fuse and fuse holder. I added some grease to the large o-ring around the base (Licor grease in the small plastic container) before reassembling everything. I followed Joe's advice to use longer helper screws help get the bottom to seat all the way in, and then replace those "helper" screws with the original screws with o-rings. During calibration for the span, I realized at 16:10 that the top heater had been on since 16:00. Probably the zero was calibrated while the heater was on. The span seemed stable from 16:12-16:18 and I don't think turning the heater off really affected it. I spanned the sensor at 16:18. After calibration, I pumped zero air into the headspace until optics RH=10%. I swapped out the old purple desiccant for a bottle of fresh blue desiccant. I added a bit of grease to the desiccant plug as well.
NL115 13056 2022-06-06 Lab none Tested Lab none I tested this CFM interface on the CR1000 in the lab. It didn't seem to have any trouble. Worked with both CF cards that I had trouble with in the field. I could ping the ethernet port. Maybe try updating the CR1000 OS in the field.
CS655 17129 2022-05-27 Bouldin Corn Soil Moisture Probe A Moved Bouldin Corn Soil Moisture Probe A Moved from under the tower in to the field after planting northwest of the tower. The tower was moved about 2m west to the edge of the field
CS655 17133 2022-05-27 Bouldin Corn Soil Moisture Probe C Moved Bouldin Corn Soil Moisture Probe C Moved from under the tower in to the field after planting west of the tower. The tower was moved about 2m west to the edge of the field
CS655 17128 2022-05-27 Bouldin Corn Soil Moisture Probe B Moved Bouldin Corn Soil Moisture Probe B Moved from under the tower in to the field after planting southwest of the tower. The tower was moved about 2m west to the edge of the field
NL115 13056 2022-05-27 Bouldin Corn Interface NL115 Removed Lab none I could not get this card reader to work with either of two CF cards. Removed for testing in the lab.
SoilVUE10 2677 2022-05-26 Lab none Installed Vaira Soil Moisture Probe I Profile Installed 5.3m at heading 220deg from the met box about a meter outside the fence near the gate.
SoilVUE10 2679 2022-05-26 Lab none Installed Vaira Soil Moisture Probe H Profile Installed 7.7m at heading 26deg from the met box near the solar panels and the old Moisture Point probe location
LI-7700 TG1-0223 2022-05-27 Mayberry Gas Analyzer CH4 Removed Lab none Removed from Mayberry because water got inside and rotted out the fuse on the bottom of the can. Same as WP a few weeks ago.
SoilVUE10 2690 2022-05-26 Lab none Installed Vaira Soil Moisture Probe F Profile Installed at 5.4m at heading 345deg from the met box about halfway between the eddy tower and radiation tower
RPI0W RPI0W-002 2021-08-17 Bouldin Corn Removed Lab none Removed from the BC field and brought back to the lab since the canopy has finished developing for this year
RPI0W RPI0W-001 2021-08-17 Bouldin Corn Removed Lab none Removed from the BC field and brought back to the lab since the canopy has finished developing for this year