Ser No.DateLoc FromTitleLoc ToNotes
EXO Wiped Cond/Temp 23D104030 2024-10-22 Lab none Calibration Lab none Sp Cond (uS/cm),Last cal: 2024-07-21
EXO sn 22C103416
EXO/Sensor Firmware 1.0.86/3.0.5
CellConstant 0.47
,Standard,PreCal,PostCal,RawValue,Temp
Pt1,5000.0 µS/cm,5078.3 µS/cm,5000.0 µS/cm, 0.0 µS/cm,21.213 °C
Note: Used USGS standard from Fondriest that expired Aug 2023. It was stored in fridge w/ cap taped and I brought it close to room temperature before calibration.
EXO Turbidity 22E106072 2024-10-22 Lab none Calibration Lab none Turbidity (FNU), Last cal: 2024-07-21
EXO sn 22C103416
EXO/Sensor Firmware: 1.0.86/3.0.4
,Standard,PreCal,PostCal,RawValue,Temp
Pt1,0.00 FNU,0.33 FNU,0.00 FNU,0.00 FNU,23.484 °C
Pt2,124.00 FNU,140.26 FNU,124.00 FNU,0.00 FNU,22.445 °C
Pt3,1010.00 FNU, 1133.83 FNU, 1010.01 FNU, 0.00 FNU, 22.568 °C
Note:
EXO fDOM 24F104438 2024-10-22 Lab none Calibration Lab none fDOM (QSU and RFU), Last cal: 2024-07-22
EXO sn 22C103416
EXO/Sensor Firmware: 1.0.86/3.0.0
,Standard,PreCal,PostCal,RawValue,Temp
Pt1,0.00 QSU,0.10 QSU,0.00 QSU,0.00 QSU,23.760 °C
Pt2,300.00 QSU,319.62 QSU,300.01 QSU,0.00 QSU,22.150 °C
Notes: Calibration solution from 2024-07-21. First calibration on new sensor.

,Standard,PreCal,PostCal,RawValue,Temp
Pt1,0.00 RFU,-.02 RFU,0.00 RFU,0.00 RFU,23.208 °C
Pt2,100.0 RFU,106.05 RFU,100.00 RFU,0.00 RFU,22.127 °C
Notes: Cal solution using QSE solution from 2024-07-20.
EXO fDOM 22C100780 2024-10-22 Lab none Calibration Lab none fDOM (QSU and RFU), Last cal:
EXO sn 23H107001
EXO/Sensor Firmware: 1.0.86/3.0.0
,Standard,PreCal,PostCal,RawValue,Temp
Pt1,0.00 QSU,-1.75 QSU,0.00 QSU,0.00 QSU,23.325 °C
Pt2,300.0 QSU,272.10 QSU,300.00 QSU,0.00 QSU,22.418 °C

,Standard,PreCal,PostCal,RawValue,Temp
Pt1,0.00 RFU,-0.61 RFU,0.00 RFU,0.00 RFU,23.221 °C
Pt2,100.00 RFU,91.28 RFU,100.00 RFU,0.00 RFU,22.440 °C
Note: Made fresh calibration solution using QSE solution from 2024-07-20. Calibrated with a mess-up calibration solution yesterday so did a factory reset before today's calibration.
CTD-10 1782503941 2024-11-20 Lab none Disposed Disposed none Disposed of in e-waste.
CS450 20010769 2024-11-20 Lab none Tested Lab none Tested overnight in the lab and seems to work fine. It stopped working at WP around the time we started having power issues, so maybe the water level data was bad b/c of power issues, not sensor issues. The exterior cable has multiple cracks in it, so we may order a long piece of heat shrink to protect it. 20' cable.
CS451 70011234 2024-11-20 Lab none Tested Lab none Ran overnight in the lab and confirmed it is working. The outside cable has many cracks and the pigtail leads are shorter than usual, so the power wires probably have to be connected to the datalogger instead of a power strip so that the Data wire can still reach the C port. 15' cable.
CS451 70011236 2024-11-18 Lab none Tested Lab none Tested in the lab and definitely broken. Placed in the "Old Sensor" box in the sensor closet.
BB-Fab 2024-11-15 Rush Ranch Battery Bank Upgrade Rush Ranch Battery Bank On about this data I the Patty upgrade this battery bank for her isotope campaign. There are six Duralast 24DC-DL batteries wired in parallel for a 12V system. These are group 24 deep cycle flooded batteries with 65Ah capacity.
CR23X 1751 2024-11-14 Lab none Maintenance Lab none First check of this data logger after salvage from RR annex location. The clock was set to 2009-01-01 (default?) the lithium battery is dead 0.48V. 99 watchdog errors, 99 skipped scans, 9 <12V errors. It's running OS v19 which is the most recent. I was able to download the existing program and saved it as RR_annex_retrieved_20241114.dll. Memory is scrambled - no thing reasonable downloaded. Maybe reloading the OS will clean it up. I'll replace it's lithium battery but it seems okay.
425A 0843 2024-11-13 Lab none For Resuse Lab none Marked for reuse
425A 0839 2024-11-13 Lab none For Resuse Lab none Marked for reuse
425A 0846 2024-11-13 Lab none For Resuse Lab none Marked for reuse
425A 0860 2024-11-13 Lab none For Resuse Lab none Marked for reuse
425A 0852 2024-11-13 Lab none For Resuse Lab none Marked for reuse
425A 0854 2024-11-13 Lab none For Resuse Lab none Marked for reuse
FMA RMT-200 08-0114 2024-11-13 Lab none For Resuse Lab none Marked for reuse
FMA RMT-200 05-0010 2024-11-13 Lab none For Resuse Lab none Marked for reuse
LAI-2000 PCA-1478 2024-11-13 Lab none For Resuse Lab none Marked for reuse
LAI-2000 PCA-0846 2024-11-13 Lab none For Resuse Lab none Marked for reuse
LI-6262 IRG3-1079 2024-11-13 Lab none For Resuse Lab none Marked for reuse
LI-6400 PSC-0785 2024-11-13 Lab none For Resuse Lab none Marked for reuse
LI-6400 PSC-2474 2024-11-13 Lab none For Resuse Lab none Marked for reuse
LI-6400 2024-11-13 Lab none For Resuse Lab none Marked for reuse
miniDOT 1219 2024-11-05 Lab none Installed East End DO Sensor Reinstalled after a trip to the lab for a clock reset, fresh desiccant, and new batteries.
LI-7500A 75H-2176 2024-11-06 Lab none Installed Hill Slough Gas Analyzer CO2/H2O Installed at Hill Slough to replace sn 0042 for calibration.
LI-7500A 0042 2024-11-06 Hill Slough Gas Analyzer CO2/H2O Removed Lab none Removed from Hill Slough for calibration. Replaced by sn 75H-2176.
LI-7500A 0073 2024-11-06 Lab none Installed Bouldin Alfalfa Gas Analyzer CO2/H2O Installed at Bouldin Alfalfa to replace sn 75H-2667 for calibration.
LI-7500A 75H-2667 2024-11-06 Bouldin Alfalfa Gas Analyzer CO2/H2O Removed Lab none Removed from Bouldin Alfalfa for calibration. Replaced by sn 0073.
CR1000 45312 2024-11-08 Lab none Upgrade Lab none I am having trouble getting FTP and ping to work on this logger. I've ruled out problems with the NL115/116, cables and ethernet switch. I could connect to the CR1000 with an IP port. It was running OS v32.02 and the newest OS is v32.07. I updated the OS hoping it would wipe whatever setting might be interfering. Nope - no luck. All the hardware works just fine on another CR1000.
EXO Central Wiper 24A100660 2024-11-08 Lab none Tested Lab none Yesterday in the field, I saw an error message that said something like "the sensor on port 7 is drawing too much power," (central port where the wiper was installed). The wiper and depth data were 0 since our last data download, although the water quality parameters (fDOM, turbidity, conductivity, temperature) had reasonable data.

Today I plugged the EXO2 in in the lab and all connected fine for about 10 seconds, until the Kor software had a pop-up window that said the instrument was disconnected. I tried disconnecting the wiper and leaving the three water quality sensors connected: the red LED on the sonde displayed the expected steady 1Hz blink and the Kor software can detect the instrument.

When the wiper was installed, the red LED on the sonde flutters ~1Hz (not a distinct blink) and the Kor software cannot detect the instrument. I tested both the central port and another port on the side but the result was the same.

I'll e-mail YSI tech support to see what they say.
CAM-SEC5IR 0030F4D0A725 2024-11-08 Lab none Upgrade Lab none I set up this Stardot camera with the latest PIT version by connecting it the router on my desk so it could talk to the internet. I edited the script files so that it sends the photos to a CR1000 card at 192.168.2.100 via FTP.
camera IP address = 192.168.2.101
camera DNS = 192.168.2.1
GMP343 N2220007 2024-11-04 Lab none Shipped Factory none Sent to Visala on quote Q-00284252, UPS tracking number 1Z0116959091064304
GMP343 N2220007 2024-11-04 Lab none Tested Lab none I connected a DB9 connector white to pin 2, green to pin 3, and power to a lithium power pack, pink to +12V and gray to G and a spare brown wire between G and pin5 on the DB9. This allowed me to communicate with the probe via a serial terminal 19200,8,N,1. These are in POLL mode: ?? gets info, SEND id gets current reading, OPEN id put it in STOP MODE so you can issue ERRS to get error info. This one had E02 and E08 bad source, bad reading. Vaisala's web site has an automated repair quote process that had a flat repair fee for about $400 and a calibration fee of about $600. I'll send it for repair.
miniDOT 1219 2024-11-04 Lab none Maintenance Lab none Set the clock with miniDOT Control Rev 1.12. The error was -2652 seconds (-44.2 min).
U20-001-04 20005770 2024-10-24 Rush Ranch Water Level A Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely used elsewhere.
LI-7700 TG1-0203 2024-10-24 Lab none Installed Rush Ranch Gas Analyzer CH4 Installed on new mount at the top of the main tower at Rush Ranch
LI-7550 AIU-1570 2024-10-24 Lab none Installed Rush Ranch Interface Installed on the main tower at Rush Ranch
LI-7500A 0418 2024-10-24 Lab none Installed Rush Ranch Gas Analyzer CO2/H2O Installed on new mount at the top of the main tower at Rush Ranch
WM 1590 120908 2024-10-24 Lab none Installed Rush Ranch Anemometer Installed on new mount at the top of the main tower at Rush Ranch
HFT3 H993105 2024-10-24 Rush Ranch Heaf Flux Plate Annex B Lost Disposed none Lost in the wetland
HFT3 H993102 2024-10-24 Rush Ranch Heaf Flux Plate Annex A Lost Lab none Lost in the wetland
CS616 13932-5 2024-10-24 Rush Ranch Soil Moisture Annex Removed Lab none Broken to be disposed of.
Quantum Q40959 2024-10-24 Rush Ranch PAR Sensor Annex Outgoing Removed Lab none Removed from the Annex tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
Quantum Q40956 2024-10-24 Rush Ranch PAR Sensor Annex Incoming Removed Lab none Removed from the Annex tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
SS-6-12V 12440075 2024-10-24 Rush Ranch Solar Controller Annex Removed Lab none Removed from the Annex tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
CR23X 1751 2024-10-24 Rush Ranch Data Logger Annex Removed Lab none Removed from the Annex location about 115m out in the wetland southwest of the tower.
WL-400-003 1202000485 2024-10-24 Rush Ranch Water Level Annex Removed Lab none Removed from the Annex tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
U20-001-04 20005768 2024-10-24 Rush Ranch Water Level C Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely used elsewhere.
U20-001-04 20005777 2024-10-24 Rush Ranch Water Level B Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely used elsewhere.
1561-LID-040/W 201906 2024-10-24 Rush Ranch Anemometer Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
CAM-SEC5IR 0030F4D0A725 2024-10-24 Rush Ranch Camera Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
7900-600 SMART2-00480 2024-10-24 Rush Ranch Interface SmartFlux Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. Probably will not be returned to the tower.
LI-7500RS 75H-1653 2024-10-24 Rush Ranch Gas Analyzer CO2/H2O Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
LI-7550 AIU-2023 2024-10-24 Rush Ranch Interface Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
Quantum Q40954 2024-10-24 Rush Ranch PAR Sensor Outgoing Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
Quantum Q40955 2024-10-24 Rush Ranch PAR Sensor Incoming Removed Lab none Removed from the main tower at Rush Ranch with the handoff of the site. To be cleaned up, tested and likely returned to the tower.
LI-7700 TG1-0203 2024-10-04 Returned none Location Lab none Brought to UCB by Kat Cone for the handoff of Rush Ranch
SI-121 1624 2024-10-29 Lab none Installed Tonzi Infrared Temperature StemFlux North Installed north of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment
CR10X 19481 2024-10-29 Lab none Installed Tonzi Data Logger StemFlux North Installed north of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment
SI-131 7638 2024-10-29 Lab none Installed Tonzi Infrared Temperature StemFlux West Installed west of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment
CR10X 3501 2024-10-29 Lab none Installed Tonzi Data Logger StemFlux West Installed west of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment
SI-131 7385 2024-10-29 Lab none Installed Tonzi Infrared Temperature StemFlux East Installed east of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment
CR10X 13214 2024-10-29 Lab none Installed Tonzi Data Logger StemFlux East Installed east of the Floor tower to measure tree trunk temperatures for Kuno's stem flux experiment
LI-7500A 0073 2024-10-29 Lab Calibration Lab Last calibration: 2024-07-12
AGC=102.8 SDM= DAC1= DAC2=
AIU sn AIU-1866, Presure A0=58.31, A1=15.48
Ambient P=100.5kPa, Tair=25.4C, Tdew=6.56C
Zero Air at 950psi, AMP FB04319 514.07 at 400 Tdewspan=20.00
CO2 zero 0.9156 -> .9156 Offset: -.27ppm
CO2 span 1.0053 -> 1.006 Offset: -.19ppm
H2O zero 0.8316 -> .8332 Offset: 9.0ppm
H2O span 1.021 -> 1.0191 Offset: .04ppm
Notes:
LI-7500A 75H-2176 2024-10-29 Lab none Calibration Lab none Last calibration: 2024-07-21
AGC=102.7 SDM= DAC1= DAC2=
AIU sn AIU-1866, Presure A0=58.31, A1=15.48
Ambient P=100.4kPa, Tair=24.6C, Tdew=6.22C
Zero Air at 975psi, AMP FB04319 514.07 at 450 Tdewspan=20.00
CO2 zero 0.8676 -> .8681 Offset: 2.22ppm
CO2 span 1.0116 -> 1.0094 Offset: 1.54ppm
H2O zero 0.8573 -> .8559 Offset: -8.1ppm
H2O span 0.9357 -> .9250 Offset: .26ppm
Notes:
LI-7500A 75H-2514 2024-10-22 Lab Calibration Lab Last calibration: 2024-07-23
AGC=99.9 SDM= DAC1= DAC2=
AIU sn AIU-1866, Presure A0=58.31, A1=15.48
Ambient P=100.6kPa, Tair=25.4C, Tdew=11.9C
Zero Air at 1100psi, AMP FB04319 514.07 at 850 Tdewspan=20.00
CO2 zero 0.9086 -> .9089 Offset: .9ppm
CO2 span 0.988 -> .9962 Offset: -5.71ppm
H2O zero 0.8457 -> .8476 Offset: 12.5ppm
H2O span 0.9823 -> .9936 Offset: -.26ppm
Notes:
LI-7500A 75H-2182 2024-10-22 Lab Calibration Lab Last calibration: 2024-06-17
AGC=100.8 SDM= DAC1= DAC2=
AIU sn AIU-1866, Presure A0=58.31, A1=15.48
Ambient P=100.7kPa, Tair=26.3C, Tdew=10.7C
Zero Air at 1050psi, AMP FB04319 514.07 at 825 Tdewspan=20.00
CO2 zero 0.885 -> .8849 Offset: -.42ppm
CO2 span 1.0141 -> 1.0136 Offset: .43ppm
H2O zero 0.8332 -> .8326 Offset: -4.3ppm
H2O span 1.0365 -> 1.0334 Offset: .07ppm
Notes:
LI-7500A 0041 2024-10-22 Lab Calibration Lab Last calibration: 2024-06-17
AGC=98.9 SDM= DAC1= DAC2=
AIU sn AIU-1866, Presure A0=58.31, A1=15.48
Ambient P=100.7kPa, Tair=25.7C, Tdew=11.4C
Zero Air at 1050psi, AMP FB04319 514.07 at 800 Tdewspan=20.00
CO2 zero 0.9958 -> .9960 Offset: .54ppm
CO2 span 1.0176 -> 1.0142 Offset: 2.36ppm
H2O zero 0.8238 -> .8244 Offset: 3.3ppm
H2O span 1.0341 -> 1.031 Offset: .08ppm
Notes:
LI-7500A 0418 2024-10-22 Lab Calibration Lab Last calibration: 2024-06-17
AGC=96.4 SDM= DAC1= DAC2=
AIU sn AIU-1866, Presure A0=58.31, A1=15.48
Ambient P=100.7kPa, Tair=26.0C, Tdew=12.4C
Zero Air at 1050psi, AMP FB04319 514.07 at 800 Tdewspan=20.00
CO2 zero 0.9064 -> .9051 Offset: -5.18ppm
CO2 span 1.0047 -> 1.0005 Offset: 3.03ppm
H2O zero 0.9346 -> .9392 Offset: 24.2ppm
H2O span 1.0084 -> 1.0016 Offset: .15ppm
Notes: The 7550 software seems to have trouble setting the CO2 span when the coefficient is right around 1.0000. The span would jump to either 513.8 or 514.4 when trying to set span with "514.07". I ended up manually adjusting the coefficient from 1.0000 to 1.0005 get the post-span concentration close to 514.07ppm.
HFP01 11332 2024-10-24 Lab none Installed Bouldin Alfalfa Heat Flux Plate C Installed in the field after wheat was planted
CS655 17132 2024-10-24 Lab none Installed Bouldin Alfalfa Soil Moisture Probe C Installed in the field after wheat was planted
HFP01 11334 2024-10-24 Bouldin Alfalfa Heat Flux Plate B Moved Bouldin Alfalfa Heat Flux Plate B Moved from under the tower into the field after wheat was planted
CS655 17135 2024-10-24 Bouldin Alfalfa Soil Moisture Probe B Moved Bouldin Alfalfa Soil Moisture Probe B Moved from under the tower into the field after wheat was planted
HFP01 10866 2024-10-24 Lab none Installed Bouldin Alfalfa Heat Flux Plate A Installed in the field after wheat was planted
CS655 17127 2024-10-24 Lab none Installed Bouldin Alfalfa Soil Moisture Probe A Installed in the field after wheat was planted
ML3 M003369 2024-10-24 Bouldin Alfalfa Soil Moisture Probe Theta Moved Bouldin Alfalfa Soil Moisture Probe Theta Moved from under the tower into the field after wheat was planted
EXO Central Wiper 24A100660 2024-10-24 Lost none Installed Hill Slough Wiper EXO Installed in the HS channel after calibration
EXO Wiped Cond/Temp 23D104030 2024-10-24 Lab none Installed Hill Slough Conductivity Sensor Installed in the HS channel after calibration
EXO fDOM 24F104438 2024-10-24 Lab none Installed Hill Slough fDOM Installed in the HS channel after calibration
EXO Turbidity 22E106072 2024-10-24 Lab none Installed Hill Slough Turbidity Installed in the HS channel after calibration
EXO2 22C103416 2024-10-24 Lab none Installed Hill Slough Interface EXO Installed in the HS channel after calibration
miniDOT 1219 2024-10-23 East End DO Sensor Removed Lab none Removed from EE and brought back to the lab to set its clock
LI-7500A 0041 2024-10-23 Lab none Installed Bouldin Corn Gas Analyzer CO2/H2O Installed at Bouldin Corn to replace sn 0035 for calibration.
LI-7500A 0035 2024-10-23 Bouldin Corn Gas Analyzer CO2/H2O Removed Lab none Removed from Bouldin Corn for calibration. Replaced by sn 0041.
LI-7500A 75H-2182 2024-10-23 Lab none Installed Mayberry Gas Analyzer CO2/H2O Installed at Mayberry to replace sn 0073 for calibration.
LI-7500A 0073 2024-10-23 Mayberry Gas Analyzer CO2/H2O Removed Lab none Removed from Mayberry for calibration. Replaced by sn 75H-2182.
miniDOT-usb 180871 2024-10-23 Gilbert Tract Removed Lab none Removed from "Upland" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
SI-121 1624 2024-10-23 Gilbert Tract Removed Lab none Removed from "Upland" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
CR10X 19481 2024-10-23 Gilbert Tract Removed Lab none Removed from "Upland" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
SI-131 7638 2024-10-23 Gilbert Tract Removed Lab none Removed from "Southside" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
CR10X 3501 2024-10-23 Gilbert Tract Removed Lab none Removed from "Southside" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
miniDOT-usb 899502 2024-10-23 Gilbert Tract Removed Lab none Removed from "Northside" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
SI-131 7385 2024-10-23 Gilbert Tract Removed Lab none Removed from "Northside" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
CR10X 13214 2024-10-23 Gilbert Tract Removed Lab none Removed from "Northside" station in Gilbert Tract at the conclusion of Robert's thermocouple experiment
EXO Central Wiper 24F104086 2024-10-23 Lab none Installed Gilbert Tract none Installed in the GT channel
EXO pH-ORP 24G102326 2024-10-23 Lab none Installed Gilbert Tract pH ORP Installed in the GT channel after calibration
EXO Wiped Cond/Temp 24F100050 2024-10-23 Lab none Installed Gilbert Tract Conductivity Sensor Channel Installed in the GT channel after calibration
EXO fDOM 22C100780 2024-10-23 Lab none Installed Gilbert Tract fDOM Installed in the GT channel after calibration
EXO Turbidity 24F102410 2024-10-23 Lab none Installed Gilbert Tract Turbidity Installed in the GT channel after calibration