Equipment and Calibration History

Page: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 [45] 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
Ser No.DateLoc FromTitleLoc ToNotes
WMP 1352 000019 2017-05-24 Tonzi-Tower Removed Lab none Removed from the Tonzi Tower. Replaced by the new Licor GHG system from Ameriflux.
NL115 6761 2017-05-24 Tonzi-Floor Removed Lab none Removed from the Tonzi Floor tower. Replaced by the new Licor GHG system from Ameriflux.
CR1000 50889 2017-05-24 Tonzi-Floor Removed Lab none Removed from the Tonzi Floor tower. Replaced by the new Licor GHG system from Ameriflux.
LI-7500A 0418 2017-05-24 Tonzi-Floor Removed Lab none Removed from the Tonzi Floor tower. Replaced by the new Licor GHG system from Ameriflux.
1189PC 000193 2017-05-24 Tonzi-Floor Removed Lab none Removed from the Tonzi Floor tower. Replaced by the new Licor GHG system from Ameriflux.
WMP 1352 000023 2017-05-24 Tonzi-Floor Removed Lab none Removed from the Tonzi Floor tower. Replaced by the new Licor GHG system from Ameriflux.
HFP01SC 00246 2017-05-26 Lab none Tested Disposed Sensor is not working. Resistance of sensor is 0 and there is no connection. The wires look pulled out at the plate.
HFP01SC 00245 2017-05-26 Lab none Repair Lab none Added silicone around the connection between wire and plate. Soldered new cable onto sensor and used clear heat shrink to attach sn and calibration information onto new cable.
CR1000 66250 2017-05-22 Lab none Upgrade Lab none OS upgraded from v27 to v31. CPU drive is reformated from FAT16 to FAT32 so complete reset of all settings. Lots of changes see CR1000_OS_31_readme.pdf
BB-Fab BB-WP 2012-05-02 Lab none Installed West Pond Battery Bank This is the initial installation of this battery bank for the West Pond Tower. Six deep cycle marine batteries from O'Reilly Auto Parts part #27DCM 175min reserve capacity were installed in parallel for a 12V system.
KU265-6MCA 158APW4M0000188 2017-05-18 Lab none Installed West Pond Solar Panel A Installed on West Pond to replace old 12V system.
KU265-6MCA 158APW4M0000189 2017-05-18 Lab none Installed West Pond Solar Panel B Installed on West Pond to replace old 12V system.
KD140SX-UFBS 11ZV0M0836 2017-05-18 West Pond Solar Panel A Removed Lab none Removed from West Pond to make way for new 24V system.
KD140SX-UFBS 11ZV0M0856 2017-05-18 West Pond Solar Panel B Removed Lab none Removed from West Pond to make way for new 24V system.
KD140SX-UFBS 11ZV0M0855 2017-05-18 West Pond Solar Panel C Removed Lab none Removed from West Pond to make way for new 24V system.
BB-Fab BB-WP 2017-05-18 West Pond Battery Bank Upgrade West Pond Battery Bank All the old batteries but one load tested week and the tower has been losing power overnight. The old batteries were replaced with new batteries from Napa Auto Parts, part #BAT 8270, 180min reserve capacity. The three old 12V 140W solar panels were replaced with two new 24V 265W panels and the battery bank was rewired as three pairs for a 24V system.
LI-7700 TG1-0211 2017-04-04 Twitchell Rice Gas Analyzer CH4 Removed Lab none Removed from Twitchell Rice site with Twitchell Rice decommissioning.
LI-7550 AIU-0650 2017-05-15 Lab none Upgrade Lab none Updated the embedded software in the LI-7550 from 8.0.0 to 8.5.0.
LI-7550 AIU-0614 2017-05-15 Lab none Upgrade Lab none Updated the embedded software in the LI-7550 from 8.0.0 to 8.5.0.
WM 1590 170523 2017-05-11 Lab none Installed Tonzi-Tower Installed on the Tower top replacing original sonic which was moved to temporary mount for inter-comparison.
LI-7550 AIU-1866 2017-05-11 Lab none Installed Tonzi-Tower Installed on the Tower one level below the top on the southwest corner post.
LI-7500A 0041 2017-05-11 Lab none Installed Tonzi-Tower Installed on the Tower top replacing original 7500 which was moved to temporary mount for inter-comparison.
LI-7550 AIU-1869 2017-05-11 Lab none Installed Tonzi-Floor Installed at Tonzi Floor tower. Most of the interface settings seemed to be correct (update rate, data stored, CO2/H2O separation), but we could not figure out how to save the sonic analog settings. The Li-7500 v 8.5 software was cut off on our computer monitor.
LI-7500A 0042 2017-05-11 Lab none Installed Tonzi-Floor Installed at the Tonzi Floor tower. I uploaded a new config file and updated the pressure coefficients. The old IRGA head, sn 0418, was moved to a temporary mount on the same tower so we can compare the old and new heads.
WM 1590 170525 2017-05-11 Lab none Installed Tonzi-Floor Installed at Tonzi Floor tower. sn 000023 was moved to a temporary mount on the same tower so that we can compare the old and new sonics.
CNR1 990181 2017-05-10 Lab none Installed Bouldin Corn Net Radiometer 4-way Installed at Bouldin Corn to calibrate against NR01 sn 2420. Joe had replaced the sensor cables recently.
LI-7550 AIU-1870 2017-05-11 Lab none Installed Vaira Interface LI-7550 Installed at Vaira to replace interface interface AIU-650.
LI-7500A 0035 2017-05-11 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed at Vaira to replace sn 75H-2150.
WM 1590 170524 2017-05-11 Lab none Installed Vaira Installed at Vaira to replace sn 153805.
LI-7550 AIU-0650 2017-05-11 Vaira Removed Lab none Removed from Vaira because the Ameriflux intercomparison finished and because we received new 7500A and sonics from Ameriflux. This interface was replaced by interface AIU-1870.
WM 1590 153805 2017-05-11 Vaira Removed Lab none Removed from Vaira because the Ameriflux intercomparison finished and because we received new 7500A and sonics from Ameriflux. This sonic was replaced with brand new sonic from Ameriflux, sn 170524.
LI-7500A 75H-2150 2017-05-11 Vaira Removed Lab none Removed from Vaira because the Ameriflux intercomparison finished and because we received new 7500A and sonics from Ameriflux. This head was replaced with sn 0035 that has been freshly upgraded from 7500 to 7500A.
CM11 996985 2017-04-04 Twitchell Rice Pyranometer Removed Lab none Removed from Twitchell Rice site with Twitchell Rice decommissioning.
LI-7500A 0035 2017-05-08 Lab none Calibration Lab none Last calibration: 2016-12-05
AGC=100 SDM= DAC1= DAC2=
Ambient P=100.4kPa, Tair=21.9C, Tdew=7.8C
Zero Air at 1550psi, LBL Air 513.22 at 350 Tdewspan=16.00
CO2 zero 0.939 -> .9381 Offset: -3.83ppm
CO2 span 1.0265 -> 1.0230 Offset: 2.41ppm
H2O zero 0.9025 -> .8974 Offset: -28.2ppm
H2O span 1.0029 -> 1.0261 Offset: -.48ppm
Notes: First calibration since upgrade from 7500 to 7500A.
HMP60 G4540021 2017-05-05 Factory Received Lab none Sensor received at lab after servicing at Campbell Sci.
HMP60 G4540021 2017-04-03 Lab none Serviced Factory Shipped to Campbell Sci for calibration. CSI Technician notes:
Tested & inspected. Refurbished RH chip. Confirmed proper function.
HMP45AC U3030032 2017-05-05 Factory Disposed Disposed Not repairable, so disposed of at CSI.
HMP45AC U3030032 2017-04-03 Lab none Serviced Factory Shipped to Campbell Sci for calibration. CSI Technician notes:
Tested & inspected. 2x4 connectors have corrosion, need replaced. Needs new o-rings. While testing sensor head, also found temp chip out of spec, drifting high in high humidity. Temperature chips are no longer available for this sensor. Sensor can not be repaired. Dispose of at CSI.
HMP45AC T0720012 2017-05-05 Factory Disposed Disposed Not repairable, so disposed of at CSI.
HMP45AC T0720012 2017-04-03 Lab none Serviced Factory Shipped to Campbell Sci for calibration. CSI Technician notes:
Inspected. Housing severely damaged, handle piece PCB non-functional, 2x4 connectors have corrosion damage. Sensor is beyond repair. Dispose of at CSI.
HMP45AC W0730036 2017-05-05 Factory Calibration Lab none Sensor received from Campbell Sci with Certificate of Calibration. Next calibration due 15-Apr-2018.
HMP45AC W0730036 2017-04-03 Lab none Serviced Factory Shipped to Campbell Sci for calibration. CSI Technician notes:
Tested & inspected. Replaced o-rings. RH chip has corrosion damage. Took before readings with original RH chip. Replaced RH chip & calibrated with documentation.
LI-7500A 0041 2017-05-05 Lab none Calibration Lab none Last calibration: 2016-12-05
AGC=99.9 SDM= DAC1= DAC2=
Ambient P=100.2kPa, Tair=22.7C, Tdew=9.22C
Zero Air at 1600psi, LBL Air 513.22 at 400 Tdewspan=16.00
CO2 zero 1.0004 -> .9969 Offset: -11.7ppm
CO2 span 1.0124 -> 1.0177 Offset: -3.72ppm
H2O zero 0.8255 -> .8210 Offset: -25.0ppm
H2O span 1 -> 1.0320 Offset: -.69ppm
Notes: First calibration since upgrade from LI-7500 to LI-7500A
LI-7500A 0042 2017-05-05 Lab none Calibration Lab none Last calibration: 2016-08-15
AGC=99.9 SDM= DAC1= DAC2=
Ambient P=100.2kPa, Tair=25.5C, Tdew=7.8C
Zero Air at 1600psi, LBL Air 513.22 at 350 Tdewspan=16.00
CO2 zero 0.9504 -> .9847 Offset: -6.7ppm
CO2 span 1.001 -> 1.0244 Offset: -15.52ppm
H2O zero 0.8519 -> .8434 Offset: -54.8ppm
H2O span 1.003 -> 1.1404 Offset: -2.72ppm
Notes: First calibration since upgrade from LI-7500 to LI-7500A
LI-7500A 0042 2017-05-03 Lab none Upgrade Lab none Upgraded to 7500A with the 7500-600 LI-7500 Head Upgrade kit from Licor. I put in new bottom assembly and greased o-ring, screws and greased o-rings, and two chemical bottles. I also adjusted the potentiometer until the waveform displayed about 15,000 counts for the minimum and 55,000 counts for the maximum(Diagnostics icon > Waveform tab). After the upgrade, I attached this sensor to a LI-7550 Analyzer Interface Unit and manually input the CO2 coefficients (A, B, C, D, E, Z, XS) and H2O coefficients (A, B, C, ZX, S). I also updated the Signal Strength coefficients (B = 1.6, C = 3.2) and reset the signal strength (Calibration icon > Signal Strength tab > Reset Signal Strength).
LI-7500A 0041 2017-05-03 Lab none Upgrade Lab none Upgraded to 7500A with the 7500-600 LI-7500 Head Upgrade kit from Licor. I put in new bottom assembly and greased o-ring, screws and greased o-rings, and two chemical bottles. I also adjusted the potentiometer until the waveform displayed about 15,000 counts for the minimum and 55,000 counts for the maximum(Diagnostics icon > Waveform tab). After the upgrade, I attached this sensor to a LI-7550 Analyzer Interface Unit and manually input the CO2 coefficients (A, B, C, D, E, Z, XS) and H2O coefficients (A, B, C, ZX, S). I also updated the Signal Strength coefficients (B = 1.6, C = 3.2) and reset the signal strength (Calibration icon > Signal Strength tab > Reset Signal Strength).
LI-7500A 0035 2017-05-03 Lab none Upgrade Lab none Upgraded to 7500A with the 7500-600 LI-7500 Head Upgrade kit from Licor. I put in new bottom assembly and greased o-ring, screws and greased o-rings, and two chemical bottles. I also adjusted the potentiometer until the waveform displayed about 15,000 counts for the minimum and 55,000 counts for the maximum(Diagnostics icon > Waveform tab). After the upgrade, I attached this sensor to a LI-7550 Analyzer Interface Unit and manually input the CO2 coefficients (A, B, C, D, E, Z, XS) and H2O coefficients (A, B, C, ZX, S). I also updated the Signal Strength coefficients (B = 1.6, C = 3.2) and reset the signal strength (Calibration icon > Signal Strength tab > Reset Signal Strength).
WM 1590 170523 2017-05-02 Lab none Initial settings Lab none All Checksum fields report PASS. Anemometer Firmware Version: 2329-701

Config file below. If there are two entries in a field, the first entry is the old setting and the second entry is the new setting.

-------

THE FOLLOWING FIELDS HAVE CHANGED

Output Message Format : M2 Polar
Output Message Format : M1 UV(W)
Resolution settings : Normal resolution
Resolution settings : High resolution
Output rate : P1 1 Hz
Output rate : P8 20 Hz
SOS and Sonic Temperature display : Neither
SOS and Sonic Temperature display : SOS
Output Channel 1 : Polar angle (wrap mode = 360 degree wrap)
Output Channel 1 : U output (full range = 30m/s)
Output Channel 2 : Polar Magnitude (full range = 5m/s)
Output Channel 2 : V output (full range = 30m/s)
Output Channel 4 : Status (status mode = Good signal high, bad signal low)
Output Channel 4 : Speed of Sound

THE NEW CONFIGURATION IN FULL

==== DETAILS OF DETECTED ANEMOMETER ========================

Serial Number : W170523

---- SW VERSION --------------------------------------------
Anemometer Firmware Version: 2329-701

---- HW DETAILS OF ANEMOMETER ------------------------------
Detected Anemometer Class : WindMaster 20Mhz
Number of AXIS on this unit : 3
DAC resolution of attached unit : 14
Number of DAC channels : 4
Maximum sampling rate : (8) P8 20 Hz

---- USER CONFIGURATION OF ANEMOMETER ----------------------
Baud Rate : 19200
Output Message Format : M2 Polar
Output Message Format : M1 UV(W)
Output Message Velocity Units : m/s
Output Message Terminator :
Retries : ON
Instantaneous Sampling : OFF
Factory Calibration : ON
Physical Communications : Auto
Resolution settings : Normal resolution
Resolution settings : High resolution
Alignment settings : North to spar
Averaging settings : Averaging inactive
Output rate : P1 1 Hz
Output rate : P8 20 Hz
Polar angle minimum magnitude: 0.050 m/s
Power-On Message : Display Power On Message
ASCII Format : Comma Separated (CSV)
SOS and Sonic Temperature display : Neither
SOS and Sonic Temperature display : SOS
Analogue output mode : -5V to 5V
Unit Identifier : 'Q'
Output Channel 1 : Polar angle (wrap mode = 360 degree wrap)
Output Channel 1 : U output (full range = 30m/s)
Output Channel 2 : Polar Magnitude (full range = 5m/s)
Output Channel 2 : V output (full range = 30m/s)
Output Channel 3 : W output (full range = 5m/s)
Output Channel 4 : Status (status mode = Good signal high, bad signal low)
Output Channel 4 : Speed of Sound
Synchronised Polling : Off
WM 1590 170524 2017-05-02 Lab none Initial settings Lab none All Checksum fields report PASS. Anemometer Firmware Version: 2329-701

Config file below. If there are two entries in a field, the first entry is the old setting and the second entry is the new setting.

-------

THE FOLLOWING FIELDS HAVE CHANGED

Output Message Format : M2 Polar
Output Message Format : M1 UV(W)
Resolution settings : Normal resolution
Resolution settings : High resolution
Output rate : P1 1 Hz
Output rate : P8 20 Hz
SOS and Sonic Temperature display : Neither
SOS and Sonic Temperature display : SOS
Analogue output mode : 0v to 5V
Analogue output mode : -5V to 5V
Output Channel 1 : Polar angle (wrap mode = 360 degree wrap)
Output Channel 1 : U output (full range = 30m/s)
Output Channel 2 : Polar Magnitude (full range = 5m/s)
Output Channel 2 : V output (full range = 30m/s)
Output Channel 4 : Status (status mode = Good signal high, bad signal low)
Output Channel 4 : Speed of Sound

THE NEW CONFIGURATION IN FULL

==== DETAILS OF DETECTED ANEMOMETER ========================

Serial Number : W170524

---- SW VERSION --------------------------------------------
Anemometer Firmware Version: 2329-701

---- HW DETAILS OF ANEMOMETER ------------------------------
Detected Anemometer Class : WindMaster 20Mhz
Number of AXIS on this unit : 3
DAC resolution of attached unit : 14
Number of DAC channels : 4
Maximum sampling rate : (8) P8 20 Hz

---- USER CONFIGURATION OF ANEMOMETER ----------------------
Baud Rate : 19200
Output Message Format : M2 Polar
Output Message Format : M1 UV(W)
Output Message Velocity Units : m/s
Output Message Terminator :
Retries : ON
Instantaneous Sampling : OFF
Factory Calibration : ON
Physical Communications : Auto
Resolution settings : Normal resolution
Resolution settings : High resolution
Alignment settings : North to spar
Averaging settings : Averaging inactive
Output rate : P1 1 Hz
Output rate : P8 20 Hz
Polar angle minimum magnitude: 0.050 m/s
Power-On Message : Display Power On Message
ASCII Format : Comma Separated (CSV)
SOS and Sonic Temperature display : Neither
SOS and Sonic Temperature display : SOS
Analogue output mode : 0v to 5V
Analogue output mode : -5V to 5V
Unit Identifier : 'Q'
Output Channel 1 : Polar angle (wrap mode = 360 degree wrap)
Output Channel 1 : U output (full range = 30m/s)
Output Channel 2 : Polar Magnitude (full range = 5m/s)
Output Channel 2 : V output (full range = 30m/s)
Output Channel 3 : W output (full range = 5m/s)
Output Channel 4 : Status (status mode = Good signal high, bad signal low)
Output Channel 4 : Speed of Sound
Synchronised Polling : Off
WM 1590 170525 2017-05-02 Lab none Initial settings Lab none All Checksum fields report PASS. Anemometer Firmware Version: 2329-701

Config file below. If there are two entries in a field, the first entry is the old setting and the second entry is the new setting.

-------

THE FOLLOWING FIELDS HAVE CHANGED

Output Message Format : M2 Polar
Output Message Format : M1 UV(W)
Resolution settings : Normal resolution
Resolution settings : High resolution
Output rate : P1 1 Hz
Output rate : P8 20 Hz
SOS and Sonic Temperature display : Neither
SOS and Sonic Temperature display : SOS
Analogue output mode : -2.5V to +2.5V
Analogue output mode : -5V to 5V
Output Channel 1 : Polar angle (wrap mode = 360 degree wrap)
Output Channel 1 : U output (full range = 30m/s)
Output Channel 2 : Polar Magnitude (full range = 5m/s)
Output Channel 2 : V output (full range = 30m/s)
Output Channel 4 : Status (status mode = Good signal high, bad signal low)
Output Channel 4 : Speed of Sound

THE NEW CONFIGURATION IN FULL

==== DETAILS OF DETECTED ANEMOMETER ========================

Serial Number : W170525

---- SW VERSION --------------------------------------------
Anemometer Firmware Version: 2329-701

---- HW DETAILS OF ANEMOMETER ------------------------------
Detected Anemometer Class : WindMaster 20Mhz
Number of AXIS on this unit : 3
DAC resolution of attached unit : 14
Number of DAC channels : 4
Maximum sampling rate : (8) P8 20 Hz

---- USER CONFIGURATION OF ANEMOMETER ----------------------
Baud Rate : 19200
Output Message Format : M2 Polar
Output Message Format : M1 UV(W)
Output Message Velocity Units : m/s
Output Message Terminator :
Retries : ON
Instantaneous Sampling : OFF
Factory Calibration : ON
Physical Communications : Auto
Resolution settings : Normal resolution
Resolution settings : High resolution
Alignment settings : North to spar
Averaging settings : Averaging inactive
Output rate : P1 1 Hz
Output rate : P8 20 Hz
Polar angle minimum magnitude: 0.050 m/s
Power-On Message : Display Power On Message
ASCII Format : Comma Separated (CSV)
SOS and Sonic Temperature display : Neither
SOS and Sonic Temperature display : SOS
Analogue output mode : -2.5V to +2.5V
Analogue output mode : -5V to 5V
Unit Identifier : 'Q'
Output Channel 1 : Polar angle (wrap mode = 360 degree wrap)
Output Channel 1 : U output (full range = 30m/s)
Output Channel 2 : Polar Magnitude (full range = 5m/s)
Output Channel 2 : V output (full range = 30m/s)
Output Channel 3 : W output (full range = 5m/s)
Output Channel 4 : Status (status mode = Good signal high, bad signal low)
Output Channel 4 : Speed of Sound
Synchronised Polling : Off

LI-7500A 75H-2180 2017-04-27 Lab none Installed Mayberry Gas Analyzer CO2/H2O Installed on Mayberry to replace sn 1594 for calibration.
LI-7500A 1594 2017-04-27 Mayberry Gas Analyzer CO2/H2O Removed Lab none Removed from Mayberry for calibration. Replaced by sn 75H-2180.
AM25T 7908 2017-04-26 Lab none Installed Bouldin Corn Multiplexer Thermocouple Installed at the Bouldin Corn site with the initial set up of the tower.
SRS-Nr NDVI 943103015 2017-04-26 Lab none Installed Bouldin Corn Narrow Band NDVI Reflected Installed at the Bouldin Corn site with the initial set up of the tower.
SRS-Ni NDVI 882103020 2017-04-26 Lab none Installed Bouldin Corn Narrow Band NDVI Incoming Installed at the Bouldin Corn site with the initial set up of the tower.
SRS-Pi PRI 913003004 2017-04-26 Lab none Installed Bouldin Corn Narrow Band PRI Incoming Installed at the Bouldin Corn site with the initial set up of the tower.
CS655 17133 2017-04-26 Lab none Installed Bouldin Corn Soil Moisture Probe C Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
CS655 17128 2017-04-26 Lab none Installed Bouldin Corn Multiplexer Thermocouple Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
CS655 17129 2017-04-26 Lab none Installed Bouldin Corn Soil Moisture Probe A Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
ML3 M003370 2017-04-26 Lab none Installed Bouldin Corn Soil Moisture Probe Theta Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
TE525MM 65548-615 2017-04-26 Lab none Installed Bouldin Corn Precipitation Installed on the top southeast corner of the scaffolding at the Bouldin Corn site with the initial set up of the tower.
PTB110 L2340502 2017-04-26 Lab none Installed Bouldin Corn Barometer Installed at the Bouldin Corn site with the initial set up of the tower.
HMP60 L1740395 2017-04-26 Lab none Installed Bouldin Corn RH & Temp Installed on the 7500 post at the Bouldin Corn site with the initial set up of the tower.
HFP01 10861 2017-04-26 Lab none Installed Bouldin Corn Heat Flux Plate C Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
HFP01 11326 2017-04-26 Lab none Installed Bouldin Corn Heat Flux Plate A Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
HFP01 10867 2017-04-26 Lab none Installed Bouldin Corn Heat Flux Plate B Installed at the Bouldin Corn site with the initial set up of the tower. Temporarily at the south edge of the scaffolding until tractor work is finished.
PQS 1 140441 2017-04-26 Lab none Installed Bouldin Corn PAR Sensor Reflected Installed in the outgoing position at the Bouldin Corn site with the initial set up of the tower.
PQS 1 140453 2017-04-26 Lab none Installed Bouldin Corn PAR Sensor Incoming Installed in the incoming position at the Bouldin Corn site with the initial set up of the tower.
NR01 2420 2017-04-26 Lab none Installed Bouldin Corn Net Radiometer 4-way Installed at the Bouldin Corn site with the initial set up of the tower.
WM 1590 074417 2017-04-26 Lab none Installed Bouldin Corn Anemometer Installed at 5.2m agl at the Bouldin Corn site with the initial set up of the tower.
LI-7700 TG1-0421 2017-04-26 Lab none Installed Bouldin Corn Gas Analyzer CH4 Installed at 5.2m agl the Bouldin Corn site with the initial set up of the tower.
LI-7550 AIU-1570 2017-04-26 Lab none Installed Bouldin Corn Interface LI-7550 Installed at the Bouldin Corn site with the initial set up of the tower.
LI-7500A 75H-2182 2017-04-26 Lab none Installed Bouldin Corn Gas Analyzer CO2/H2O Installed at 5.2m agl at the Bouldin Corn site with the initial set up of the tower.
AM16/32B 21690 2017-04-26 Lab none Installed Bouldin Corn Multiplexer Met Installed at the Bouldin Corn site with the initial set up of the tower.
LI-7500A 75H-2182 2017-04-20 Lab none Calibration Lab none Last calibration: 2016-12-19
AGC=87.9 SDM= DAC1= DAC2=
Ambient P=101.1kPa, Tair=22.4C, Tdew=8.19C
Zero Air at 1600psi, NOAA CO2 513.22 at 350 Tdewspan=16.00
CO2 zero 0.8837 -> 0.8838 Offset: 0.12ppm
CO2 span 1.0207 -> 1.0164 Offset: -2.98ppm
H2O zero 0.8457 -> 0.8454 Offset: -1.9ppm
H2O span 1.0186 -> 1.0139 Offset: 0.1ppm
Notes:
LI-7500A 75H-2180 2017-04-20 Lab none Calibration Lab none Last calibration: 2016-12-23
AGC=100.5 SDM= DAC1= DAC2=
Ambient P=101.1kPa, Tair=23.6C, Tdew=7.63C
Zero Air at 1600psi, NOAA CO2 513.22 at 250 Tdewspan=16.00
CO2 zero 0.9145 -> 0.9144 Offset: -0.53ppm
CO2 span 1.0287 -> 1.026 Offset: 1.83ppm
H2O zero 0.8836 -> 0.8861 Offset: -1.4ppm
H2O span 1.0124 -> 1.023 Offset: 0.5ppm
Notes: I re-did the H2O zero because the first offset was large, so I wanted to double check. The first offset was 16.8 mmol/m3. The second offset was -1.4 mmol/m3, so I felt confident in the calibration.
CS451 70011236 2017-04-04 Twitchell Rice Water Level Removed Lab none Removed with Twitchell Rice tower decommissioning.
PTB110 H0160093 2017-04-04 Twitchell Rice Barometer Removed Lab none Removed with Twitchell Rice tower decommissioning.
NR-LITE 990352 2017-04-04 Twitchell Rice Net Radiometer Removed Lab none Removed with Twitchell Rice tower decommissioning.
CS511 DO-8 2017-04-04 Twitchell Rice DO Sensor Removed Lab none Removed with Twitchell Rice tower decommissioning.
PAR-LITE 050596 2017-04-04 Twitchell Rice PAR Sensor Reflected Removed Lab none Removed with Twitchell Rice tower decommissioning.
PAR-LITE 050597 2017-04-04 Twitchell Rice PAR Sensor Incoming Removed Lab none Removed with Twitchell Rice tower decommissioning.
SD130BN 0030F4D21491 2017-04-11 Factory Returned Lab none Returned from repair at Stardot. Factory said the reset button was jammed with bird guano.
SD130BN 0030F4D21491 2017-02-24 Lab none Shipped Factory Shipped to Stardot for repair on RMA #022317AAW with the help of Andrew Richardson. This unit got rained on when the enclosure was left open by some unknown force. It seems to power up but can not connect to it. Internally it looks okay.
LED-4chan RYU-01 2017-04-05 Tonzi-Tower Removed Lab none Removed from the Tonzi tower. This sensor has not been giving good readings for awhile. Replaced by one of our LED sensors.
LI-7500A 75H-2150 2017-04-10 Twitchell Rice Gas Analyzer CO2/H2O Installed Vaira Gas Analyzer CO2/H2O Added to the Vaira eddy tower for the Ameriflux inter-comparison and the transition to newer LI-7500A eddy systems.
LI-7550 AIU-0650 2017-04-10 Twitchell Rice Interface LI-7500 Installed Vaira Interface LI-7500 Added to the Vaira eddy tower for the Ameriflux inter-comparison and the transition to newer LI-7500A eddy systems.
WM 1590 153805 2017-04-10 Lab none Installed Vaira Added to the Vaira eddy tower for the Ameriflux inter-comparison and the transition to newer LI-7500A eddy systems.
LI-7500A 0073 2017-04-10 Lab none Installed Vaira Gas Analyzer CO2/H2O Installed on the Vaira tower to replace sn 0041 for calibration.
LI-7500A 0041 2017-04-10 Vaira Gas Analyzer CO2/H2O Removed Lab none Removed from Vaira for calibration. Replaced by sn 0073.
LI-7500 0976 2017-04-10 Lab none Installed Tonzi-Tower Installed on the Tonzi Tower to replace sn 0035 for calibration
LI-7500A 0035 2017-04-10 Tonzi-Tower Removed Lab none Removed from Tonzi Tower for calibration. Replaced by sn 0976
LI-7500 0976 2017-04-07 Lab none Calibration Lab none Last calibration: 2016-08-15
AGC=57 SDM=7 DAC1=0-1000 DAC2=10-25
Ambient P=99.9kPa, Tair=21.3C, Tdew=12.16C
Zero Air at 1600psi, NOAA CO2 513.22 at 400 Tdewspan=16.01
CO2 zero 0.8594 -> 0.8594 Offset: -0.01ppm
CO2 span 1.0083 -> 1.0097 Offset: -1.12ppm
H2O zero 0.6317 -> 0.6348 Offset: 21.6ppm
H2O span 1.0114 -> 0.9689 Offset: 0.95ppm
Notes: Notes from last time said that the hood thermistor was not used and that there was a large change in H2O zero. I used hood thermistor this time and large offsets in H2O zero and span. Set span temperature to 15.94 in software for the spanned temperature to match the dewpoint generator at 16.01.
LI-7500A 0073 2017-04-07 Lab none Calibration Lab none Last calibration: 2017-01-18
AGC=59 SDM=7 DAC1=0-1000 DAC2=10-25
Ambient P=100.1kPa, Tair=20.17C, Tdew=10.72C
Zero Air at 1600psi, NOAA CO2 513.22 at 350 Tdewspan=16.01
CO2 zero 0.9573 -> 0.9578 Offset: 0.06ppm
CO2 span 1.0037 -> 1.0036 Offset: 0.08ppm
H2O zero 0.7394 -> 0.7388 Offset: -3.0ppm
H2O span 1.0063 -> 1.0096 Offset: -0.07ppm
Notes: Had to set span temperature at 15.95 in software for the spanned temperature to reach 16.01, the temperature on the dew point generator
AM25T 2856 2017-04-04 Twitchell Rice Multiplexer Thermocouple Removed Lab none Removed with the decommissioning of the Twitchell Rice site.
CR23X 2303 2017-04-04 Twitchell Rice Data Logger Met Removed Lab none Removed with the decommissioning of the Twitchell Rice site.
HMP45AC U3030046 2017-04-04 Twitchell Rice RH & Temp Removed Lab none Removed with the decommissioning of the Twitchell Rice site.
HFP01 6499 2017-04-04 Twitchell Rice Heat Flux Plate C Removed Lab none Removed with the decommissioning of the Twitchell Rice site.
HFP01 10822 2017-04-04 Twitchell Rice Heat Flux Plate B Removed Lab none Removed with the decommissioning of the Twitchell Rice site.
HFP01 10809 2017-04-04 Twitchell Rice Heat Flux Plate A Removed Lab none Removed with the decommissioning of the Twitchell Rice site.