Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

Fieldnotes Limited To:
Site = Mayberry
Year = 2013

2010 | 2011 | 2012 | 2013 | 2014 | 2015 | 2016 | 2017 | 2018 | 2019 | 2020 | 2021 | 2022 | 2023 | 2024
36 Rows returned:
SiteDateAuthorSummary
Mayberry (353) 2013-12-19 10:10:00 Joe Verfaillie Standard data collection, did not visit tule tower of collect water samples.
Mayberry (340) 2013-12-06 12:30:00 Cove Sturtevant Installed new conductivity probe, but need to check program. Swapped IRGA.
Mayberry (325) 2013-11-21 09:50:00 Cove Sturtevant 7550 firmware update. Data download. Recent rains gave tower a bath. All generally well.
Mayberry (317) 2013-11-13 10:00:00 Cove Sturtevant Vegetation survey
Mayberry (310) 2013-11-06 10:30:00 Cove Sturtevant Water level low. Ants in box with cables. Took some notes on vegetation.
Mayberry (289) 2013-10-16 10:00:00 Cove Sturtevant Serviced DO probes. Pulled conductivity, tule water CO2, and open water 2 thermocouples for repair. Took manual water level measurement.
Mayberry (275) 2013-10-02 10:15:00 Cove Sturtevant Standard site visit and data download. Otters pulled out 7700 washer tube, reconnected. Confirmed that tule/water RNET data streams have been switched since inception. Rechecked sonic direction.
Mayberry (261) 2013-09-18 09:15:00 Cove Sturtevant Standard site visit. All A-OK.
Mayberry (254) 2013-09-11 10:30:00 Cove Sturtevant Standard site visit. Lots of cottony material in 7500 path. Otherwise, all well.
Mayberry (248) 2013-09-05 09:20:00 Cove Sturtevant Standard site visit. Other than some disheveled bird spikes on sonic, all good.
Mayberry (240) 2013-08-28 14:40:00 Cove Sturtevant HMP45 hanging loose from shield, reinstalled. Water level high. Replaced 7700 washer fluid tubing.
Mayberry (233) 2013-08-21 14:20:00 Cove Sturtevant Calibrated 7700. 7700 washer line needs replacing.
Mayberry (226) 2013-08-14 11:45:00 Cove Sturtevant Data download. All well. Took GPS reading of tower location.
Mayberry (217) 2013-08-05 13:30:00 Cove Sturtevant Standard site visit. All generally well.
Mayberry (212) 2013-07-31 10:25:00 Cove Sturtevant Bumped flux system to 20 Hz. All well.
Mayberry (207) 2013-07-26 15:05:00 Cove Sturtevant Data download. 7700 reservoir was empty and RSSI low. Cleaned crusty off mirror.
Mayberry (197) 2013-07-16 09:45:00 Cove Sturtevant Removed open water CO2 probe for maintenance. Tower height only ~1 m above veg, might want to raise tower.
Mayberry (191) 2013-07-10 10:15:00 Joe Verfaillie Data collection, swapped 7500 head, water samples, measured eddy sensor positions
Mayberry (178) 2013-06-27 09:25:00 Cove Sturtevant Standard site visit. All well.
Mayberry (169) 2013-06-18 10:40:00 Cove Sturtevant Changed 7550 time to ETC/GMT +8. Added CO2 signal strength to output. All well.
Mayberry (164) 2013-06-13 11:00:00 Cove Sturtevant Water samples. Changed 7550 clock back 1 day. Replaced LED sensor cover. All well.
Mayberry (156) 2013-06-05 16:50:00 Cove Sturtevant Site in full growth mode. Took water samples and cleaned sensors. Updated 7550 firmware. 7550 clock was a day ahead, corrected.
Mayberry (144) 2013-05-24 16:30:00 Cove Sturtevant Data collection, changed time zone on 7550 and 7700 to Etc/GTM-8
Mayberry (129) 2013-05-09 14:40:00 Cove Sturtevant Adjusted 7550 clock to UTC. All well.
Mayberry (116) 2013-04-26 11:15:00 Cove Sturtevant Site continues to green. Fixed tule CO2 thermocouple. Vaisala t/rh was out of radiation shield. Set 7550 clock to London time instead of UTC (whoops). All else well.
Mayberry (101) 2013-04-11 10:15:00 Joe Verfaillie Wetland plants continue to green up, weeds are going wild, standard field work
Mayberry (95) 2013-04-05 12:00:00 Joe Verfaillie Checked tower, installed tule CO2 probe, folks at the duck camp.
Mayberry (87) 2013-03-28 10:45:00 Cove Sturtevant Tules greening along margins. Tower reading well. Waspies getting active. Pulled #2 water CO2 sensor for testing.
Mayberry (80) 2013-03-21 11:00:00 Cove Sturtevant New tule growth along margins. 7700 still had line lock (woohoo!). Did not replace. Collected water samples. All well.
Mayberry (73) 2013-03-14 10:40:00 Cove Sturtevant Water level low. CO2 probes out of water. Reinstalled lower DO probe. Line lock on 7700 lost again. No data collection from 7700. Reset all and currently collecting okay. Return next week for check. Adjusted clock on 7700 back to standard time.
Mayberry (59) 2013-02-28 10:40:00 Cove Sturtevant Re-installed surface DO probe. Removed lower DO probe for testing. 7500 readings okay, but replaced main cable anyway. 7700 lost line lock again, loose power cable found.
Mayberry (52) 2013-02-21 12:00:00 Joe Verfaillie LI7700 lost line lock - reset, 7700 calibrated, 7500 reporting bad chopper temp - could not fix, replace set of TCs at Tule Tower, removed surface DO.
Mayberry (45) 2013-02-14 10:30:00 Cove Sturtevant Lots of cottony material out and about, lots of algae in water. Swapped out 7500 and 7550 for upgraded firmware. Set up wireless MET connection (AWESOME!).
Mayberry (30) 2013-01-30 14:00:00 Cove Sturtevant Water instruments gunky, cleaned. Tule CO2 probe was floating, replaced in PVC tube. All else well.
Mayberry (17) 2013-01-17 11:00:00 Cove Sturtevant Installed new tule CO2 sensor, resealed autocam housing glass, some adjustments needed to new wireless system. Need long cable ties. All generally well.
Mayberry (3) 2013-01-03 12:40:00 Cove Sturtevant Tower good. Downloaded data. Pulled tule CO2 sensor for repair. Glass front to autocam housing loose.
 
 

Login