Site | Date | Author | Summary |
Tonzi/Vaira |
(341) 2001-12-07 09:00:00 |
Dennis Baldocchi |
Removed 4 of 6 new batteries to fix charging issues.
|
Tonzi |
(314) 2001-11-10 10:30:00 |
Dennis Baldocchi |
Power on tower was down upon arrival; installed moisture point MP 917 soil probes; swapped licors.
|
Tonzi/Vaira |
(284) 2001-10-11 09:00:00 |
Ted Hehn |
Working on power systems, new Floor program, new Vaira met program
|
Tonzi/Vaira |
(257) 2001-09-14 09:00:00 |
Ted Hehn |
Added PC watch dog to Vaira, Removed three KZ PAR sensor
|
Tonzi/Vaira |
(218) 2001-08-06 08:30:00 |
LiuKang Xu |
Cows got inside the fence at Vaira, power problems.
|
Tonzi/Vaira |
(214) 2001-08-02 09:00:00 |
LiuKang Xu |
Both flux systems running, data downloaded. 6400 measurements
|
Tonzi/Vaira |
(204) 2001-07-23 08:30:00 |
LiuKang Xu |
Checking systems - reboots, ACi curves
|
Vaira |
(183) 2001-07-02 14:52:00 |
Dennis Baldocchi |
Fixed and installed soil moisture sensors, soil samples, checked flux system.
|
Tonzi/Vaira |
(176) 2001-06-25 09:00:00 |
Dennis Baldocchi |
Rained in the region
|
Vaira |
(172) 2001-06-21 15:00:00 |
Ted Hehn |
Check PC.
|
Vaira |
(171) 2001-06-20 14:56:00 |
Ted Hehn |
Replace PC enclosure, replace PC, remove PC battery
|
Vaira |
(171) 2001-06-20 07:58:00 |
Dennis Baldocchi |
pc 208 edlog function does not work on system; pc mouse bug, opening various windows and icons.
|
Vaira |
(170) 2001-06-19 14:54:00 |
Ted Hehn |
Changed power management settings on PC.
|
Tonzi/Vaira |
(166) 2001-06-15 08:00:00 |
LiuKang Xu |
Eddy hung at Vaira reboot, ACi curves, replace Tower laptop, gates and lids were left open last time.
|
Vaira |
(160) 2001-06-09 14:43:00 |
Ted Hehn |
Replaced PC batteries, removed PAR sensors.
|
Vaira |
(159) 2001-06-08 14:33:00 |
Ted Hehn |
Reconnected soil probe, reprogrammed PC, site maintenance.
|
Vaira |
(157) 2001-06-06 13:53:00 |
Ted Hehn |
Trouble shooting with pressure bomb, checked flux towers, started aspirator at Tonzi.
|
Vaira |
(152) 2001-06-01 15:08:00 |
Ted Hehn |
Cleaned solar panels, installed Windows 2K on PCs.
|
Vaira |
(151) 2001-05-31 09:00:00 |
Dennis Baldocchi |
Extreme heat killed grass & also caused malfunction in LI 6400; drought effect on oaks uses more air than usual from tank; T/Rh is aspirated.
|
Vaira |
(145) 2001-05-25 09:30:00 |
Dennis Baldocchi |
5/25/ 2001 Cloudy and Hot
9:30 at Vaira ranch, stop the gillsonic program and reboot the computer.
At Tonzi
A_PAR measuremnts. Around 10:45 download flux data from the tower and floor systems. At 12:15 check both systems , both running good.
|
Vaira |
(144) 2001-05-24 09:00:00 |
LiuKang |
No system issues, downloaded flux and met data.
|
Vaira |
(140) 2001-05-20 13:49:00 |
Ted Hehn |
On Sunday, 20 May, the tower radiation system became operational. The Temp/RH sensor I installed did not work correctly and will be replaced on my next site visit. Although we are currently logging this data, the MD9/PC208 configuration has not been insta
|
Vaira |
(137) 2001-05-17 09:00:00 |
LiuKang |
Data was not retrieved due to computer problems.
|
Vaira |
(131) 2001-05-11 09:00:00 |
Dennis Baldocchi |
Li-cor batteries low voltage; data downloaded and systems running properly.
|
Tonzi |
(127) 2001-05-07 00:00:00 |
Ted Hehn |
Quantum line sensor moved to Tonzi; rain gauge sensor tripped multiple times.
|
Vaira |
(124) 2001-05-04 09:00:00 |
Dennis Baldocchi |
On 5/4 Fri. d124
Li-Cor 6400 measurements on Oak trees at Tonzi ranch. in the morning 4 A/Ci curves and inthe afternoon 4 A_PAR curves. Vcmax, calculated by using the initial slope of dA/dCi, seems increased lot last week, please see summarized file on S
|
Tonzi/Vaira |
(123) 2001-05-03 09:00:00 |
LiuKang Xu |
Forgot tripod for 6400, standard data collection
|
Vaira |
(123) 2001-05-03 09:00:00 |
Dennis Baldocchi |
Downloaded raw data, met and soil data collected, site instruments running properly.
|
Tonzi/Vaira |
(117) 2001-04-27 09:00:00 |
LiuKang Xu |
ACi curves, Swapped 7500 at Vaira, grass height and LAI
|
Vaira |
(108) 2001-04-18 09:00:00 |
Dennis Baldocchi |
April 18, 2001: D108
Vaira Ranch :
Canopy height measurement: 28 samples, mean=18,5 cm , std=4.7 cm. Leaf water potential and A/Ci curve measurement at Tonzi ranch.
|
Vaira |
(107) 2001-04-17 17:00:00 |
Dennis Baldocchi |
April 17 D107
1700 Looks like the time when the cows got into the met station and chewed through wires
|
Tonzi/Vaira |
(98) 2001-04-08 10:00:00 |
Unknown |
No raw data files fond on laptop, file set up changed to 1 & gillsonic restarted.
|
Vaira |
(96) 2001-04-06 00:00:00 |
Unknown |
Downloaded data - started to rain see more notes on 04/08
|
Vaira |
(81) 2001-03-22 12:00:00 |
Dennis Baldocchi |
Swapped IRGAs; fixed Licor sensor; reinstalled commercial voltage converter; swapped T/RH sensors.
|
Vaira |
(74) 2001-03-15 10:00:00 |
Dennis Baldocchi |
Changed CR23x program, removed soil moisture/heat fluxes; T/RH sensor was dead for a few days.
|
Vaira |
(72) 2001-03-13 10:53:00 |
LiuKang |
Check flux system, PC, batteries, and chamber collars.
|
Vaira |
(72) 2001-03-13 00:00:00 |
Dennis Baldocchi |
PC208 was not communicating with the CR10x; adjusted batteries providing energy for proper procedure.
|
Vaira |
(67) 2001-03-08 10:15:00 |
Dennis Baldocchi |
Computer was dead, could not collect a lot of data.
|
Vaira |
(60) 2001-03-01 16:00:00 |
Dennis Baldocchi |
D60, March 1
We down loaded flux data at about 1610 to 1700 hours. Took 2 samples of plant matter. We noticed that the soil moisture sensors were not giving the right output. Needed to put the red wire on 12 v dc. Now we are getting good signals. The soi
|
Vaira |
(54) 2001-02-23 10:10:00 |
Dennis Baldocchi |
Replaced Li-cor 7500; finished setting up step relay MUX for soil temperature and moisture measurements.
|
Vaira |
(54) 2001-02-23 09:00:00 |
Dennis Baldocchi |
Ted changing cr10x program.
|
Vaira |
(47) 2001-02-16 10:45:00 |
Dennis Baldocchi |
Data logger on the soil system was dead; cows chewed through soil sensor cable; raingauge finally fixed.
|
Vaira |
(40) 2001-02-09 00:00:00 |
Dennis Baldocchi |
Feb 9. Raining in the region
|
Vaira |
(39) 2001-02-08 11:00:00 |
Dennis Baldocchi |
Swapped Licors; fixed programs that renamed campbell data logger filed; growth is low for measured plant height.
|
Vaira |
(38) 2001-02-07 00:00:00 |
Dennis Baldocchi |
html
Feb 7, 2001
Ted is documenting the LICOR IRGAS. Found #35 CO2 on the scale of 10 to 25 mmol m-3 for the 0 to 5 volt scale. This was the setting I had used in Oregon
We set #42 originally at 13-20 mmol m-3 for the 0
|
Vaira |
(30) 2001-01-30 09:00:00 |
Dennis Baldocchi |
Zip drive and power inverter missing, could not collect data; swapped Incoming Par sensor; swapped out IRGA with number 75b-0073.
|
Vaira |
(16) 2001-01-16 00:00:00 |
Dennis Baldocchi |
Communication wire between laptop and met station damaged.
|
Vaira |
(5) 2001-01-05 10:30:00 |
Dennis Baldocchi |
Swapped out Gillsonic and Licor; system is drying down (due to the drought).
|
Vaira |
(3) 2001-01-03 10:00:00 |
Dennis Baldocchi |
Fixed md9 systems and fixed communications between computer and data loggers; the sonic was dead.
|