Site | Date | Author | Summary |
Mayberry |
(116) 2024-04-25 10:15:00 |
Kyle Delwiche |
We installed 10 more porewater sippers in the non-vegetated area, and sampled existing sippers.
|
Mayberry |
(114) 2024-04-23 12:20:00 |
Daphne Szutu |
Installed one profile of porewater sippers in the channel, added CTD to floating boom
|
Mayberry |
(107) 2024-04-16 13:05:00 |
Daphne Szutu |
Maintenance visit, removed CTD to send back to factory, reconnected 2nd VWC, flushed 3 of the clogged porewater wells, removed a clogged porewater well
|
Mayberry |
(102) 2024-04-11 10:40:00 |
Daphne Szutu |
Visitors Gelary and Ash, swapped 7500 for calibration, Campbell conductivity sensor in mud--adjusted, Campbell water level mostly NANs--fixed maybe, "developed" porewater sippers produced sample!
|
Mayberry |
(100) 2024-04-09 09:45:00 |
Kyle Delwiche |
Testing porewater sippers
|
Mayberry |
(95) 2024-04-04 10:15:00 |
Daphne Szutu |
Installed Campbell water level sensor, one VWC disconnected--more work needed, three porewater samples
|
Mayberry |
(85) 2024-03-25 11:00:00 |
Daphne Szutu |
Visitors, low water level, happy weeds, new pepperweed population, water level sensor not working--needs swap
|
Mayberry |
(74) 2024-03-14 13:25:00 |
Joe Verfaillie |
Windy, levees mowed, can't find cause of water level NANs, Some sipper data, lower water level
|
Mayberry |
(59) 2024-02-28 12:10:00 |
Daphne Szutu |
Water level lower, cattails coming up, attempted all porewater sippers and got 4 samples
|
Mayberry |
(47) 2024-02-16 10:30:00 |
Kyle Delwiche |
Today's goal was to sample the sippers Daphne and I had installed on Monday.
|
Mayberry |
(43) 2024-02-12 12:15:00 |
Daphne Szutu |
Kyle D. installed homemade sippers--hard to draw sample, no dfPAR data for past two weeks--fixed, lots of blowdown from recent storms
|
Mayberry |
(30) 2024-01-30 11:30:00 |
Daphne Szutu |
Warm day, storm prep, + Kyle, installed VWC sensors in wetland to measure conductivity, removed porewater sippers for clean-up
|
Mayberry |
(18) 2024-01-18 12:25:00 |
Daphne Szutu |
Water level still low, dfPAR data spotty--needs more work, PG&E working on power pole removal project
|
Mayberry |
(11) 2024-01-11 11:35:00 |
Daphne Szutu |
Calibrated 7700, dfPAR motor bad--swapped, removed water radiometers, not enough water for porewater conductivity
|
Mayberry |
(4) 2024-01-04 14:00:00 |
Joe Verfaillie |