Tonzi: 2001-11-10 10:30:00 (DOY 314)
Author: Dennis Baldocchi
Others: Liukang Xu

Summary: Power on tower was down upon arrival; installed moisture point MP 917 soil probes; swapped licors.

Field notes

Who: Db and Lx
Where: Tonzi/Vaira
When: D310 Nov 10, 2001

Arrived around 1030.

1. Power on the Tower system was down. The plug to the pc has poor contact. With some jiggling we got it up and running.
2. Moved raingauge above the solar panels
3. Noticed lots of bird manure on solar panel. We need a mop and water to clean them occasionally
4. The net radiometer was slightly dirty. We need to either adjust the mount, so it can be rotated up and cleaned or have a cleaning device on an arm to reach the sensor.
5. Changed code on CR23x. The time of the watch dog reset was changed from 1500 ms to 6000 ms. This was on instruction 22. We need to download and save changes to PC. This was not done.
6. Installed Moisture point MP 917 soil probes. The probes are segmented and measure soil moisture at 15 cm increments down to 60 cm. Sensors were put near the tower sn 00000931AFE , near the floor system sn 000000402165, near the floor solar panel sn 000000574B4B, near a sap flow tree sn 000000402FF3 and in between the soil respiration transect sn 000000574632. Three sensors are under trees and 2 are in the open. Whenever someone goes to the site, please make measurements of these probes manually. The electronics are in the storage box and the cable is stored in the tool box, to protect it from rodents.
7. We moved the fence and protected the understory solar panel system
8. We moved the un connected solar panel array to the old fencing.
9. Rain was expected the next day. A very little grass is germinating from the Oct 31 rain, but not much.
10. battery voltage on the CR 23 x on the tower was 11.3 volts. It is not connected to the solar array.

Vaira, 1500 hours

1. Swapped licors. sn 0041 came off and sn 0042 went on
2. Installed two moisture point soil moisture sensors
3. The range has been much heavily grazed, compared to Tonzi.
4. Low soil moisture values in top level, may be an artifact of installation and gaps between sensor and soil. It need to adjust. Deep soil moisture values are much lower than oak savanna at Tonzi, circa 11% vs ~18 to 20%.

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
No data found for TZ_windprof.
No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.