Site | Date | Author | Summary |
West Pond |
(351) 2020-12-16 11:45:00 |
Daphne Szutu |
Regular data collection/cleaning, hunting day, new gate code, changed calib PAR to face downward, swapped 7700 reservoir power cable
|
West Pond |
(338) 2020-12-03 11:30:00 |
Daphne Szutu |
Regular data collection/cleaning, swapped 7500 for calibration, added METER Atmos14 for AirT/RH intercomparison, water level low, 7700 wash not working consistently--need new power cable
|
West Pond |
(324) 2020-11-19 12:05:00 |
Joe Verfaillie |
Swapped 7700, added test system for cross check T, RH and PAR, upgraded DC power strips
|
West Pond |
(308) 2020-11-03 09:30:00 |
Daphne Szutu |
Regular data collection/cleaning, 7700 pump had no power--fixed, water level much lower, moved and lowered miniDOT from air into water
|
West Pond |
(296) 2020-10-22 11:20:00 |
Daphne Szutu |
Regular data collection/cleaning, water level lower, lowered minidot into water, camera off--no photos, changed eddy clock +2min
|
West Pond |
(288) 2020-10-14 09:00:00 |
Ariane Arias-Ortiz |
Surface and porewater sampling
|
West Pond |
(283) 2020-10-09 12:30:00 |
Ariane Arias-Ortiz |
Surface and porewater sampling, 3rd consecutive week of sampling after flooding
|
West Pond |
(279) 2020-10-05 08:50:00 |
Daphne Szutu |
Regular data collection/cleaning, hazy air, inlet on and water level high, camera/sonic spikes pointed down, loose wire on 24V-12V converter--fixed, trimmed willows
|
West Pond |
(274) 2020-09-30 09:30:00 |
Ariane Arias-Ortiz |
Surface and porewater monthly collection
|
West Pond |
(267) 2020-09-23 09:30:00 |
Daphne Szutu |
Regular data collection/cleaning, water level back up, dirty radiometers, 2 thermocouples not working
|
West Pond |
(266) 2020-09-22 10:10:00 |
Ariane Arias-Ortiz |
Surface and porewater sampling, the wetland is flooded, water coming out the inlet is a bit more saline than in the past
|
West Pond |
(254) 2020-09-10 13:25:00 |
Joe Verfaillie |
Out of cycle visit, still no water, solar power system seems okay - washed panels. Willows need trimming
|
West Pond |
(253) 2020-09-09 17:30:00 |
Ariane Arias-Ortiz |
Checked water level, the wetland is still dry
|
West Pond |
(245) 2020-09-01 15:05:00 |
Daphne Szutu |
Regular data collection/cleaning, hazy air, water level still low
|
West Pond |
(234) 2020-08-21 09:05:00 |
Ariane Arias-Ortiz |
Regular data download and porewater sampling, boards were put back at the outlets, installed miniDOT, swapped 7500 for calibration
|
West Pond |
(218) 2020-08-05 09:25:00 |
Daphne Szutu |
Regular data collection/cleaning, wasp nest under solar panels
|
West Pond |
(213) 2020-07-31 09:30:00 |
Ariane Arias-Ortiz |
collected porewater samples and removed outlet boards
|
West Pond |
(203) 2020-07-21 09:10:00 |
Daphne Szutu |
Regular data collection/cleaning, removed miniDOT from tower to bury underground, water samples for Ariane
|
West Pond |
(189) 2020-07-07 13:30:00 |
Ariane Arias-Ortiz |
Surface and porewater samples
|
West Pond |
(183) 2020-07-01 08:50:00 |
Daphne Szutu |
Regular data collection/cleaning, inlet was on, lots of water
|
West Pond |
(168) 2020-06-16 08:45:00 |
Joe Verfaillie |
New 7700 wash tubing, water level high, cleaned solar panels
|
West Pond |
(161) 2020-06-09 08:30:00 |
Joe Verfaillie |
Ariane taking water samples, standard data download, water level still getting lower.
|
West Pond |
(150) 2020-05-29 09:00:00 |
Joe Verfaillie |
Calibrated conductivity, temporarily fixed leaks in 7700 wash tubing, cleaned camera window
|
West Pond |
(140) 2020-05-19 13:15:00 |
Daphne Szutu |
Regular data collection/cleaning, peat core collection, 7700 calibration, swapped 7500 for calibration, installed miniDOT, cleaned conductivity sensor. Ariane - soil core
|
West Pond |
(130) 2020-05-09 09:10:00 |
Ariane Arias-Ortiz |
Monthly surface and porewater sampling
|
West Pond |
(122) 2020-05-01 11:40:00 |
Daphne Szutu |
Regular data collection/cleaning, breezy, water level is up a lot, missing last few days of camera data, first site visit in a month
|
West Pond |
(102) 2020-04-11 10:00:00 |
Ariane Arias-Ortiz |
Installation of Sedpoint2 for permanent monitoring of porewaters and porewater sampling
|
West Pond |
(94) 2020-04-03 12:55:00 |
Daphne Szutu |
Regular data collection/cleaning, first site visit in a month
|
West Pond |
(71) 2020-03-11 11:00:00 |
Joe Verfaillie |
Sheep grazing on surrounding levees, improved power connection at the box, restarted camera
|
West Pond |
(65) 2020-03-05 11:35:00 |
Daphne Szutu |
Regular data collection/cleaning, Ariane took 50cm soil core
|
West Pond |
(51) 2020-02-20 11:55:00 |
Joe Verfaillie |
Swapped 7500, swapped water level desiccant.
|
West Pond |
(43) 2020-02-12 09:21:00 |
Ariane Arias-Ortiz |
Regular monthly porewater collection
|
West Pond |
(37) 2020-02-06 13:15:00 |
Daphne Szutu |
Regular data collection/cleaning, no photos on camera card, water level still low
|
West Pond |
(23) 2020-01-23 09:20:00 |
Daphne Szutu |
Regular data collection/cleaning, not much water in wetland, Ariane's water samples, replaced HMP fan, added desiccant to camera housing
|
West Pond |
(7) 2020-01-07 12:00:00 |
Daphne Szutu |
Regular data download/collection, low water level, serviced water sensors, removed miniDOT, updated 7700 wash settings
|