Summary: Regular data collection/cleaning, hunting day, new gate code, changed calib PAR to face downward, swapped 7700 reservoir power cable

2020-12-16
West Pond

I arrived at 11:45 PST. It was chilly and it was a lot foggier here than on Sherman Island earlier in the day, but there was some weak sunshine coming in through the clouds. There were about 4-5 cars parked by the rice fields for the hunting day. At the tower, the staff gauge read 14cm. I noticed some sheep droppings on the grass roads leading to the tower, but maybe they were there last time. In any case, all the weeds are pretty brown so I’m not sure what they were eating.

I downloaded met, camera, and USB GHG data. I cleaned the flux and rad sensors. The radiometers had some condensation on their sensors. The HMP60 sensor fan was not working. There were no spare 12V fans in the bag, so I put in a 24V fan for now (maybe this is why RH has been railed high? I need to check last time this fan was changed). There was also a 7700 time sync error which was resolved with a 7550 box reset. Since the water level was a little higher today, I raised the minidot by one chain link so it’s not resting against the mud.

The reservoir was ½ empty; I refilled it. The 7700 pump was not working when I tested it, so I swapped the reservoir power cable.

I also downloaded the intercomparison data. I changed the Ameriflux calibration PAR sensor sn 060831 so it was facing downwards.

We could have a potential work day here in the near future. The tower is tilting to the NE. I would also like to neaten the cables--they're crisscrossing everywhere and half are in split loom, half are not. Maybe swap the Canon camera for a phenocam. The camera window is very foggy in the winter, and its view changes with each site visit. At some point we will also be removing the intercomparison sensor and swapping the tower HMP60 for a HMP155.

I left at 12:40 PST.

I had followed in when arriving on Twitchell Island, but unfortunately, the combo had changed so I was stuck on the inside of the gate when I tried to leave. I think Bruce changes it every year for the new hunting season. After a few minutes someone from GrowWest stopped at the gate to come in. After I told him the old combo, he told me that Bruce had texted him with the new combo. I’ve e-mailed the combo to Joe and Ari. Next year we’ll have to remember to ask Bruce for the new combo. I’ll put it on the to-do list.

0 photos found

Graphs display:
8 sets found

Can't check WP_DO
1 WP_DO graphs found

Explore the graph:WestPond DO in a new window

14 WP_met graphs found

Explore the graph:Battery in a new window

Explore the graph:Temperatures in a new window

Explore the graph:Solar Radiation in a new window

Explore the graph:RH and Pressure in a new window

Explore the graph:Water Level and Precipitation in a new window

Explore the graph:Conductivity in a new window

Explore the graph:Temperatures Set A in a new window

Explore the graph:Temperatures Set B in a new window

Explore the graph:Temperature Set C in a new window

Explore the graph:Water CO2 and Temp in a new window

Explore the graph:West Pond Water CO2 in a new window

Explore the graph:WP miniDOT Dissolved Oxygen in a new window

Explore the graph:SRS NDVI Channels in a new window

Explore the graph:NDVI in a new window

5 WP_flux graphs found

Explore the graph:Winds in a new window

Explore the graph:LI7500 CO2 and H2O in a new window

Explore the graph:LI7700 CH4 and RSSI in a new window

Explore the graph:West Pond Flux Data Counts in a new window

Explore the graph:Air Temperatures in a new window

Can't check MBWPEESWGT_mixed
Can't check MBEEWPSWEPGT_cam
Can't check MBSWEEWPBCBA
1 WP_processed graphs found

Explore the graph:WP CO2 Fluxes in a new window

No data found for WP_arable.