Field Notes

Fieldnotes Limited To:
Site = West Pond
Year = 2023

2012 | 2013 | 2014 | 2015 | 2016 | 2017 | 2018 | 2019 | 2020 | 2021 | 2022 | 2023 | 2024
28 Rows returned:
SiteDateAuthorSummary
West Pond (356) 2023-12-22 12:50:00 Joe Verfaillie Standard data collection, inlet not running, losing data at night again.
West Pond (341) 2023-12-07 16:00:00 Daphne Szutu Regular data collection/cleaning, cold day after chamber/soil sampling at Gilbert Tract in the morning
West Pond (324) 2023-11-20 13:50:00 Daphne Szutu Regular data collection/cleaning, HMP fan dead--swapped
West Pond (310) 2023-11-06 13:55:00 Daphne Szutu Regular data collection/cleaning, complete data, picam download quit partway--restarted
West Pond (300) 2023-10-27 13:00:00 Joe Verfaillie Standard data collection, batteries still holding up, old boardwalk and well pipe uncovered by goats
West Pond (291) 2023-10-18 15:45:00 Daphne Szutu Quick stop to check power--ok, M4.2 earthquake today
West Pond (284) 2023-10-11 13:50:00 Daphne Szutu Complete data over the past week, plugged 7700 back in, frogs!
West Pond (277) 2023-10-04 16:05:00 Daphne Szutu Added 4th battery to battery bank, 7500 PLL error--swapped, trimmed willows
West Pond (271) 2023-09-28 13:25:00 Daphne Szutu Regular data collection/cleaning, losing power nightly--trimmed willow by solar panels, 7500 PLL error--fixed?, disconnected 7700 to save power
West Pond (262) 2023-09-19 16:45:00 Joe Verfaillie Testing solar batteries, down to two good ones, lots of ants, restart camera after power was down.
West Pond (255) 2023-09-12 13:30:00 Daphne Szutu Regular data collection/cleaning, very tall vegetation, losing data overnight--needs more attention, measured sonic orientation
West Pond (235) 2023-08-23 13:45:00 Joe Verfaillie Standard data collection, hot, Hot, HOT. Testing LI-7810 chamber system, tested 7700 wash - ok, replaced DC-DC converter and fixed loose connection
West Pond (220) 2023-08-08 13:20:00 Daphne Szutu Regular data collection/cleaning, installed new water level sensor, loose wire inside met box causing power issues--needs more work
West Pond (205) 2023-07-24 14:20:00 Daphne Szutu Regular data collection/cleaning, water level sensor NAN--needs swap, power flickering--fixed maybe
West Pond (192) 2023-07-11 11:05:00 Daphne Szutu Regular data collection/cleaning, hot day, swapped 7500 for calibration, weird power issues - swapped DC-DC converter, HMP155 no data - fixed
West Pond (179) 2023-06-28 09:50:00 Daphne Szutu Regular data collection/cleaning, Cliff taking bulk soil samples, NDVI no data--fixed, web-spinning spider mites on willows!
West Pond (166) 2023-06-15 12:00:00 Daphne Szutu Regular data collection/cleaning, 7700 calibration, reset 7700 cleaning/heating settings, improved the power cable, lots of ants/ant eggs in met box
West Pond (151) 2023-05-31 12:45:00 Daphne Szutu No power at tower--fixed temporarily
West Pond (137) 2023-05-17 11:15:00 Daphne Szutu Regular data collection/cleaning, levee roads have been mowed, trimmed willow back
West Pond (115) 2023-04-25 12:40:00 Daphne Szutu Regular data collection/cleaning, tall grass on levee roads, short power outage last week, HMP not working--fixed
West Pond (93) 2023-04-03 13:00:00 Daphne Szutu Regular data collection/cleaning, some new reeds coming up, noisy frogs, some corrupt photos on Canon card--deleted, swapped 7500 for calibration
West Pond (76) 2023-03-17 13:10:00 Daphne Szutu Regular data collection/cleaning, visitors from UCSC, a few small plants coming up, lots of water
West Pond (61) 2023-03-02 13:35:00 Daphne Szutu Regular data collection/cleaning, lots of water in the wetland
West Pond (45) 2023-02-14 14:00:00 Daphne Szutu Regular data collection/cleaning, cold and windy, updated picam program to latest version with file compressions
West Pond (32) 2023-02-01 12:17:00 Daphne Szutu Regular data collection/cleaning, no power issues in last 2 weeks, first download from picam, workers improving interior levee roads, stung by a wasp
West Pond (18) 2023-01-18 13:25:00 Daphne Szutu Regular data collection/cleaning, inspected power system--removed 2 bad batteries, calibrated 7700, installed picam for intercomparison, replaced wood in lower boardwalk
West Pond (6) 2023-01-06 15:00:00 Daphne Szutu Regular data collection/cleaning, swapped 7500 for calibration, losing power sporadically, storms this week and more rain to come
West Pond (3) 2023-01-03 13:50:00 Daphne Szutu Quick stop for storm prep, Bruce said half of Twitchell Island lost power