Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2024-04-16 10:00:00 |
Other sites visited today: West Pond | East End | Bouldin Corn | Bouldin Alfalfa

Hill Slough: 2024-05-01 14:45:00 (DOY 122)
Author: Daphne Szutu
Others: Joe

Summary: Super low tide, all channel sensors were out of the water, actively bubbling water/mud

2024-05-01
Hill Slough

Joe and I arrived at 14:45 PST (15:45 PDT). It was a warm day but surprisingly not as windy as the other sites of the day. It was super low water level. The mud level was 3.3 feet on the channel staff gauge, and the water level was below that by at least 30cm. All of the water sensors were above the water by about 5cm: the EXO, miniDOT, and eosGP.

There was maybe about 5cm of muddy water in the channel.

We could see and hear a lot of bubbles coming up through the mud and through the shallow water of the channel. It sounded like a gently simmering pot of water, or like the burbling of one of those geothermal mud pits.

There were lot of interesting animal tracks in the mud.
We still need to replace the CTD here. We have one in the lab with a shortened cable. The upper boardwalk is starting to sound weak.

I downloaded met, cam, and USB GHG data. Joe cleaned flux and rad sensors and reported lots of spiderwebs everywhere. The wash reservoir was 2/3 full; I refilled it.

The 7500 read: 420ppm CO2, 153 mmol/m3 H2O, 27.3C, 101.4kPa, 96SS -- 98 after cleaning
The 7700 read: 2.0ppm CH4, 39RSSI – 88 after cleaning

Joe took a porewater sample. There was lots of bubbles in the sample, so he had to draw the plunger all the way out, closed the valve and removed the syringe to push out the headspace, then attached the syringe again and pulled the plunger again to get enough liquid for the sample. There was no surface water at the tower, but we measured the channel water on the way out. The channel number jumped around a lot.

Sample, Temperature-compensated conductivity, Water temperature, Notes
Pore water, 5.59mS, 24.8C
Surface, 4.2mS, 29.9C, sampled channel and reading jumped a lot between 3.8-4.5mS

We left at 15:15 PST (16:15 PDT).

3 photos found

A green mat of algae on the mud flat to the north
20240501HS_GreenMat.jpg ( 2024-05-01 16:03:34 ) Full size: 1920x1440
A green mat of algae on the mud flat to the north

The water sensors are in the air at low tide
20240501HS_DryWaterSensors.jpg ( 2024-05-01 15:48:10 ) Full size: 1920x1440
The water sensors are in the air at low tide

Close up of the algae on the mud
20240501HS_Algae.jpg ( 2024-05-01 16:13:26 ) Full size: 1440x1920
Close up of the algae on the mud

Graphs display:
4 sets found

20 HS_met graphs found

Temperatures

Temperature Profile A

Temperature Profile B

Temperature Profile C

Soil Heat Flux

Four-channel radiometer

NDVI Channels

PAR

Air Pressure

Air T and RH

pCO2

Soil Moisture

Battery Voltage

Forced Diffusion Soil CO2 Flux

Dissolved Oxygen

Water Level

Conductivity

EXO pH + ORP

EXO Turbidity + fDOM

Water Temp

4 HS_flux graphs found

CO2 and H2O

Wind

Methane

Data Counts

1 HS_cam graphs found

GCC

Can't check HS_Processed
2 HS_Processed graphs found

Energy

CO2, CH4 Net Fluxes

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.