Site | Date | Author | Summary |
West Pond |
(353) 2013-12-19 12:30:00 |
Joe Verfaillie |
Standard data collection, fixed HMP60 fan, inlet off but water high, swapped 7500
|
West Pond |
(340) 2013-12-06 08:20:00 |
Cove Sturtevant |
Frost. Need to replace HMP45 fan. Otherwise, all good.
|
West Pond |
(325) 2013-11-21 12:35:00 |
Cove Sturtevant |
Water level under tower high. Data download. 7550 firmware update. New Met program. All good.
|
West Pond |
(310) 2013-11-06 14:00:00 |
Cove Sturtevant |
Data download. Ants in Met box largely gone. All well.
|
West Pond |
(297) 2013-10-24 12:00:00 |
Joe Verfaillie |
De-ant-ified, plugged ports, filled wash reservoir, new inlet running, water high.
|
West Pond |
(289) 2013-10-16 14:40:00 |
Cove Sturtevant |
New inlet constructed but not running. Water level at tower low. Ants still in Met box, need more putty to reseal.
|
West Pond |
(275) 2013-10-02 12:30:00 |
Cove Sturtevant |
Collected water samples, downloaded data. Ants have colonized the Met box, but no problems.
|
West Pond |
(261) 2013-09-18 10:30:00 |
Cove Sturtevant |
Standard site visit. Check water CO2 probe temperature in the data.
|
West Pond |
(254) 2013-09-11 13:00:00 |
Cove Sturtevant |
Regular site visit. All good.
|
West Pond |
(248) 2013-09-05 12:30:00 |
Cove Sturtevant |
Water level under tower normal, but inlet not running. East pond drained and browning. All good.
|
West Pond |
(240) 2013-08-28 10:00:00 |
Cove Sturtevant |
Water low and inlet not running. Bryan said he would turn inlet back on. Put washer clip back on 7700. All well, no ants in 7550 box :)
|
West Pond |
(233) 2013-08-21 10:40:00 |
Cove Sturtevant |
East pond water low. Calibrated 7700. Swapped out 7500 and 7550. Moved 7550 location to top scaffold tier. Replaced broken shield for 7700 thermocouple. Updated 7700 time to GMT+8.
|
West Pond |
(226) 2013-08-14 10:10:00 |
Cove Sturtevant |
Some trouble connecting to 7550, will swap out for ant-free box next week. Took GPS reading of tower location.
|
West Pond |
(217) 2013-08-05 11:15:00 |
Cove Sturtevant |
Inlet running, normal water under tower. Ants interminable. Thermocouple shroud in 7700 path broken, but thermocouple ok.
|
West Pond |
(212) 2013-07-31 13:30:00 |
Cove Sturtevant |
No water under tower again. 7550 ants resilient, added more silicone to door seal. Otherwise, well.
|
West Pond |
(207) 2013-07-26 10:25:00 |
Cove Sturtevant |
Accidentally tore inflatable pipe with car. No water under tower. Ant problem still present in 7550 box. Data download. Bumped flux system to 20 Hz. Leveled radiometer and PAR sensors.
|
West Pond |
(197) 2013-07-16 12:20:00 |
Cove Sturtevant |
Inlet running at low flow, no water under tower. Ant problem nearly gone. Took instrument orientation measurements. Veg height approaching tower height.
|
West Pond |
(191) 2013-07-10 12:30:00 |
Joe Verfaillie |
Inlets running but no water under scaffolding, east pond very low too, ants infestation improving, measured sensor locations
|
West Pond |
(178) 2013-06-27 11:15:00 |
Cove Sturtevant |
Tules growing tall, some approaching tower height. Ant infestation down a notch. All else well.
|
West Pond |
(171) 2013-06-20 09:40:00 |
Sara Knox |
Closed 7550 box. Water levels low again. We Were only able to take water samples at pier F.
|
West Pond |
(169) 2013-06-18 14:40:00 |
Cove Sturtevant |
Water under tower a bit low. Changed 7550 time to ETC/GMT +8. Added CO2 signal strength to output, removed Diag Value #2 from output. Added another ant bait and left 7550 door open to encourage ants to leave. Knocked down wasp nests.
|
West Pond |
(164) 2013-06-13 15:45:00 |
Cove Sturtevant |
Ant infestation in 7550 even larger. Placed ant bait. Everything still working ok.
|
West Pond |
(156) 2013-06-05 14:45:00 |
Cove Sturtevant |
Lots of new growth. Tules under tower getting close to sensors. Inlet running but water low. Ant infestation in 7550. Took water samples. Updated 7550 firmware. Corrected pressure cal. 7550 clock was a day ahead, corrected.
|
West Pond |
(144) 2013-05-24 15:10:00 |
Cove Sturtevant |
Collected data, change 7550 and 7700 time zone to Etc/GMT-8, borrowed 7550 Ethernet cable.
|
West Pond |
(129) 2013-05-09 14:00:00 |
Cove Sturtevant |
Site slowly greening. All well.
|
West Pond |
(116) 2013-04-26 13:20:00 |
Cove Sturtevant |
Site starting to green up a bit. Inlet was not running. Swapped out 7500 head. Changed 7550 to UTC time.
|
West Pond |
(101) 2013-04-11 12:30:00 |
Joe Verfaillie |
Standard field work, still looks brown
|
West Pond |
(95) 2013-04-05 14:00:00 |
Joe Verfaillie |
Quick check of WP and DC, a look at the alfalfa fields.
|
West Pond |
(87) 2013-03-28 11:45:00 |
Cove Sturtevant |
Site remains mostly senescent. All well.
|
West Pond |
(80) 2013-03-21 12:30:00 |
Cove Sturtevant |
Took water samples, checked instruments. All well.
|
West Pond |
(73) 2013-03-14 13:00:00 |
Cove Sturtevant |
Inlet not running. Adjusted 7550 clock back to standard time and removed Date/Time fields from GHG output.
|
West Pond |
(59) 2013-02-28 13:40:00 |
Cove Sturtevant |
Water samples and data download. All well.
|
West Pond |
(52) 2013-02-21 10:00:00 |
Joe Verfaillie |
Calibrated 7700, water not running - left message with Jim, 7500 AGC reading 0.0?
|
West Pond |
(45) 2013-02-14 14:15:00 |
Cove Sturtevant |
Inlet running well. All A-ok.
|
West Pond |
(30) 2013-01-30 10:35:00 |
Cove Sturtevant |
Inlet is NOT RUNNING. Water level low. Lowered DO and CO2 probe to 3 cm under water. All else well.
|
West Pond |
(17) 2013-01-17 14:00:00 |
Cove Sturtevant |
Installed water CO2 sensor. Ice layer still present at 14:00! All well.
|
West Pond |
(3) 2013-01-03 09:00:00 |
Cove Sturtevant |
Downloaded data. Pulled upper DO sensor for install at Twitchell. Swapped out 7550 and 7500. Some ice in 7700 reservoir. All well.
|