Site | Date | Author | Summary |
West Pond |
(352) 2017-12-18 17:08:00 |
Daphne Szutu |
Regular data collection/cleaning, Removed HMP60 for field test
|
West Pond |
(334) 2017-11-30 14:00:00 |
Daphne Szutu |
Regular data collection/cleaning
|
West Pond |
(314) 2017-11-10 14:00:00 |
Daphne Szutu |
Regular data collection/cleaning
|
West Pond |
(299) 2017-10-26 12:15:00 |
Daphne Szutu |
Regular data collection/cleaning
|
West Pond |
(292) 2017-10-19 14:40:00 |
Daphne Szutu |
Dropped off scaffolding and ladder
|
West Pond |
(286) 2017-10-13 09:15:00 |
Joe Verfaillie |
Swapped both 7500 and 7700 for calibration, added moth balls to boxes.
|
West Pond |
(269) 2017-09-26 12:30:00 |
Daphne Szutu |
Regular data collection/cleaning, did not record 7700 data for past two weeks, dropped off scaffolding from TT2 Closed Canopy tower
|
West Pond |
(256) 2017-09-13 09:15:00 |
Daphne Szutu |
Regular data collection/cleaning, water level low, uploaded LI-7550 master configuration file
|
West Pond |
(242) 2017-08-30 09:20:00 |
Daphne Szutu |
Regular data collection/cleaning
|
West Pond |
(228) 2017-08-16 12:20:00 |
Joe Verfaillie |
Reinstalled water CO2, tall veg in sensors, tractor work on levees.
|
West Pond |
(216) 2017-08-04 14:00:00 |
Joe Verfaillie |
mothballs, tractor work to raise Levees.
|
West Pond |
(214) 2017-08-02 11:36:00 |
Ada Chang |
There was an ant explosion.
|
West Pond |
(200) 2017-07-19 09:45:00 |
Daphne Szutu |
Regular data collection and cleaning, trimmed vegetation by tower/boardwalk, eosense CO2 sensor maxing out at 5V,
took Li-6400 photosynthesis measurements
|
West Pond |
(193) 2017-07-12 12:30:00 |
Patty Oikawa |
took peat core next to tower
|
West Pond |
(184) 2017-07-03 11:01:00 |
Ada Chang |
Swapped camera and 7500.
|
West Pond |
(178) 2017-06-27 17:26:00 |
Sam Chamberlain |
Soil iron sampling
|
West Pond |
(178) 2017-06-27 16:00:00 |
Joe Verfaillie |
Replacing camera power supplied failed, camera needs replacing
|
West Pond |
(174) 2017-06-23 14:58:00 |
Ada Chang |
Did not swap LI7500. Camera was off.
|
West Pond |
(156) 2017-06-05 11:50:00 |
Joe Verfaillie |
Data collection, added NDVI sensors, swapped water CO2 sensor.
|
West Pond |
(145) 2017-05-25 11:30:00 |
Daphne Szutu |
Regular data collection and cleaning, No Licor GHG data since 5/18
|
West Pond |
(138) 2017-05-18 09:40:00 |
Joe Verfaillie |
Upgraded solar system, new panels, new batteries, more scaffolding, 24V system
|
West Pond |
(130) 2017-05-10 12:45:00 |
Daphne Szutu |
Regular data collection/cleaning, camera power was off
|
West Pond |
(117) 2017-04-27 11:45:00 |
Daphne Szutu |
Regular data collection/cleaning
|
West Pond |
(101) 2017-04-11 12:25:00 |
Daphne Szutu |
Regular data collection/cleaning, tower is tilted, not sure if HMP fan is working
|
West Pond |
(88) 2017-03-29 12:50:00 |
Daphne Szutu |
Regular data collection/cleaning, swapped HMP60 shield/fan
|
West Pond |
(82) 2017-03-23 12:20:00 |
Daphne Szutu |
Calibrated 7700, updated CR1000 program
|
West Pond |
(74) 2017-03-15 12:55:00 |
Daphne Szutu |
Regular data collection/cleaning, swapped 7500
|
West Pond |
(60) 2017-03-01 13:00:00 |
Daphne Szutu |
Regular data collection/cleaning, Grassy road leading to tower very muddy/pitted - avoid for now
|
West Pond |
(54) 2017-02-23 13:20:00 |
Daphne Szutu |
Deployed new eosense CO2 probe, collected met data
|
West Pond |
(44) 2017-02-13 13:05:00 |
Daphne Szutu |
regular data collection/cleaning, pulled eosense CO2 probe
|
West Pond |
(31) 2017-01-31 11:25:00 |
Elke Eichelmann |
Regular data collection, foggy, blow down of vegetation
|
West Pond |
(17) 2017-01-17 13:00:00 |
Daphne Szutu |
Regular data collection, swapped sonic
|
West Pond |
(5) 2017-01-05 12:30:00 |
Daphne Szutu |
Standard data collection, tules blown down since last visit
|