Equipment and Calibration
View History
Equipment Entry
|
Documents
Calibration: cal_KippZonen_PARLite_sn060831_20200110.pdfReport: WP Golden Set comparison 2020 - 2020-11-19
Report: Bouldin Corn - Radiometer Calibration 2021 - 2021-06-09
Report: Hill Slough - Radiometer Calibration 2021 - 2021-06-22
Report: West Pond - Radiometer Calibration 2021 - 2021-06-22
Report: East End - Radiometer Calibration 2021 - 2021-07-21
History
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
5560 | 2021-11-08 | Lab none | Returned | Returned none | Returned to Sebastien of AMP in exchange for a freshly calibrated reference PAR sn 212225 |
5570 | 2021-11-05 | Cal Kit PAR Sensor Incoming | Removed | Lab none | Removed from BA tower at the conclusion of the rad calibration and brought back to the lab. This sensor will go back to AMP. |
5536 | 2021-10-21 | Cal Kit PAR Sensor Reflected | Moved | Cal Kit PAR Sensor Incoming | Moved from GT Reflected to BA Incoming as part of the radiometer cal kit to begin the calibration at BA |
5718 | 2021-10-07 | Cal Kit PAR Sensor Incoming | Moved | Cal Kit PAR Sensor Reflected | Moved at GT from incoming to reflected to continue inter-comparison |
5458 | 2021-09-15 | Cal Kit PAR Sensor Reflected | Moved | Cal Kit PAR Sensor Incoming | Moved from MB to the new Gilbert Tract GT site to continue the radiometer intercomparison there. |
5426 | 2021-08-17 | Cal Kit PAR Sensor Reflected | Moved | Cal Kit PAR Sensor Incoming | Moved from EE to MB after completion of radiometer intercomparison at EE |
5390 | 2021-07-21 | Cal Kit PAR Sensor Reflected | Moved | Cal Kit PAR Sensor Incoming | Moved from WP to EE at the conclusion of the radiometer inter-comparison at WP |
5347 | 2021-06-22 | Cal Kit PAR Sensor Reflected | Moved | Cal Kit PAR Sensor Incoming | Moved from HS to WP as part of the radiometer calibration kit at the conclusion of the 2-week intercomparison at HS. |
5344 | 2021-06-16 | Cal Kit PAR Sensor Incoming | Moved | Cal Kit PAR Sensor Reflected | Moved at HS from the incoming position to the reflected position |
5322 | 2021-06-09 | Cal Kit PAR Sensor Reflected | Moved | Cal Kit PAR Sensor Incoming | Moved from BC to HS as part of rad cal kit |
5294 | 2021-06-02 | Cal Kit PAR Sensor Incoming | Moved | Cal Kit PAR Sensor Reflected | Moved from the incoming position to the reflected position for continuing inter-comparison. |
5309 | 2021-05-27 | Lab none | Installed | Cal Kit PAR Sensor Incoming | Installed at BC as part of the cal kit in the incoming position |
5150 | 2021-03-02 | Cal Kit PAR Sensor Reflected | Removed | Lab none | Removed from TZ Tower top with the calibration kit |
5305 | 2021-02-10 | Cal Kit PAR Sensor Incoming | Moved | Cal Kit PAR Sensor Reflected | Moved at TZ from the incoming position to the reflected position to continue inter-comparison. |
5059 | 2021-01-21 | Lab none | Installed | Cal Kit PAR Sensor Incoming | Installed at TZ in the incoming position as part of the inter-comparison kit to test PAR, AirT and RH on the top of the Tower. |
5307 | 2021-01-17 | Cal Kit PAR Sensor Reflected | Removed | Lab none | Removed from WP with the cal kit |
5306 | 2020-12-16 | Cal Kit PAR Sensor Incoming | Moved | Cal Kit PAR Sensor Reflected | Moved from the incoming position to the reflected position to continue the inter-comparison at WP |
4976 | 2020-11-19 | Lab none | Installed | Cal Kit PAR Sensor Incoming | This is the Ameriflux standard installed at WP for cross comparison with existing sensors |
5310 | 2020-06-04 | Factory none | Calibration | Factory none | y=mx+b 149.48 0; The date for this entry is made up but allows this calibration to be used as needed. After discrepancies with an inter-comparison on Tonzi Tower in the spring to 2021 and a conversation with Sebastien Biraud on 2021-05-05 we learned that the OSU calibration for this senor was no good and the subsequent calibration that this entry represents should be used instead. The OSU calibration uses a lamp and fails for certain PAR sensors for unknown reasons. This calibration is done at LBL outside under ambient conditions cross compared with ten other PAR sensors. |
4942 | 2020-01-10 | Factory none | Calibration | Factory none | y=mx+b 131.80 0 Calibrated by Chad Hanson at OSU as part of the Ameriflux standard program 7.59 uV/umol/m2/s |