Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2011-03-01 09:30:00 | 2011-04-13 09:45:00-->
Other sites visited today: Sherman Island | Mayberry

Twitchell Rice: 2011-03-22 09:30:00 (DOY 81)
Author: Joe Verfaillie
Others: Dennis, Jaclyn, Emily

Summary: Calibrated LGR, started computer, tipping bucket lost funnel and pyramnometer lost shield in wind - replaced, DO pulled from field.

Twitchell
2011-03-22

I arrived about 9:30 with Dennis, Jaclyn, and Emily. It was cool and breezy with the wind coming from the east. It was sunny with a few clouds here and there. The field is drained but still wet with all the recent rain.

All seemed to be running okay. The LGR reported:

8:25PST, 17.01C, 130.91Torr, 17.042usec, 10Hz, 2.290ppm

I adjusted the bypass valve and then turned off the LGR. I started to swap in another mouse and keyboard, but discovered the current on was plugged into the wrong ports. I swapped the current mouse and keyboard plugs and the keyboard and mouse worked on restart. So I did a calibration with the 3.276ppm tank with 750psi. Last cal was Nov 24, 2010.

Pre cal: 8:42PST, 17.16C, 156.57Torr, 17.042usec, 1Hz, 3.347ppm – about 70ppb off.
Post cal: 3.277ppm

Before we left the LGR read:
8:55PST, 17.42C, 149.22Torr, 17.068usec, 10Hz, 2.176ppm

Jaclyn got about 750 images off the plant cam. We ran a 12V line to the plant cam and removed the AA batteries. All seemed well.

The computer was off. I restarted it and copied the data.

Jaclyn swapped the card on the CR1000.

Dennis pulled the DO sensor from the field.

The wind had blown the funnel and screen off the tipping bucket. Jaclyn taped it back on.

The wind had also blown the radiation shield off the pyranometer. Dennis swapped the desiccant before replacing the shield.

I need to spray some WD40 on the combo locks.

2 photos found

UC Davis on site
TW_plantcam_20110322_0958.jpg ( 2011-03-22 09:58:00 ) Full size: 2560x1920
UC Davis on site

UC Davis on site
TW_plantcam_20110322_1158.jpg ( 2011-03-22 11:58:00 ) Full size: 2560x1920
UC Davis on site

Graphs display:
6 sets found

12 TW_met graphs found

Soil Heat Flux

Solar Radiation

Air Temperature

Soil Temperature Set 1

Soil Temperature Set 2

Soil Temperature Set 3

Water Temperature

RH and Pressure

Soil Moisture

Rain and Water Level

Disolved Oxygen

LED NDVI Channels

5 TW_flux graphs found

Sonic Anemometer Winds

LI7700 CH4 and RSSI

Twitchell CH4

LI7500 CO2 and H2O

Twitchel Rice Flux Counts

Can't check TWSI_mixed
Can't check SIMBTWEE_met
1 TW_cam graphs found

TW Rice Autocam

Can't check TATWBABCSB_cam

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.