Tonzi: 2006-12-26 11:30:00 (DOY 360)
Author: Siyan Ma
Others:


When: Date: 12/26/2006 , Day: 360 , Watch Time: 11:30am .
Where: Tonzi/Vaira Ranch
Who: Siyan
Weather: cloudy, windy
Phenology: grass germination, 3-4cm tall in Varia, 1-3cm tall in Tonzi. Oak leaves have fallen off. Grass didn’t change very much since last visit.
Summary
  1. Power problem on Floor site!!! Screen showed “VGA NO INPUT SIGNAL”. Looks like there’s no enough power to run the screen. So, I disconnected Screen and Keyboard with the PC to save power. I also opened CD drive to save more power. PC was reset up after disconnections.
  2. Soil CO2 profile: something wrong with sensors on the open site!!! Readings were all zero.
  3. Check and download data at Tower and Varia. EC systems worked well.
  4. Measured groundwater, dendrometer, and spectrometer. Dendrometers need reset because some have been out of range!!!

Groundwater: roadside 36.97 ft; tower 32.45 ft; understory 27.16 ft. Groundwater raised ~0.5ft compared with the measurements on Dec. 6, 2006.
Vaira_Grass Site
  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 12.4 v; 1.9 amps; 3.2 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

Time

11:44:05

Path/File name

D:\Data\V06_ 360 .flx
D:\Data\VR063601000.raw


mean

std


mean

std

w

0.23

0.82

Ts

20.96

0.19

u

-5.5

2.07

H2O

1.5

0.061

v

-1.97

1.26

CO2

2.09

0.008




TC

1.38

0.139
  1. downloading data OK
  2. check the fans of air temp. and relative humidity sensors at Vaira. OK
  3. Check MD-9 system connections OK
  4. Closed gate and set up fence. OK

Tonzi_Tower Site

  1. Fence and gate power: >12 v.
  2. Panel and Batteries: 12.0 v; 0.0 amps; 6.7 amps.
  3. Reading from Gillsonic screen before downloading data. (The value of H2O and CO2 should be in the range of 0 – 5 v.)

13:06:18

10:53:28

Path/File name

D:\Data\T06_360 .flx
D:\Data\TW063601300.raw


mean

std


mean

std

w

0.65

0.788

Ts

20.06

0.236

u

-1.68

0.788

H2O

1.86

0.057

v

1.51

1.908

CO2

1.99

0.019
  1. downloading data OK
  2. PC time was about a few second difference from GPS.
  3. check the fans of air temp. and relative humidity sensors on the tower and the floor.
  4. Check calibration cylinders;

CO2 1600 psig; flow 18 psi.
N2 1400 psig; flow 20 psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running‌ OK
  1. close gate and set up fence. OK

Toniz_Floor Site
  1. Power problem on Floor site!!!
  2. Screen showed “VGA NO INPUT SIGNAL”. Looks like there’s no enough power to run the screen. So, I disconnected Screen and Keyboard with the PC to save power. I also opened CD drive to save more power. PC was reset up after disconnections. Sounds OK.
  3. I couldn’t download data and check MD-9 system connections.
  4. Soil CO2 profile: something wrong with sensors on the open site!!! Readings were all zero.

Reading from datalogger

Panel temp

16.27



Battery voltage

12.4



CO2E_1

0

TCE_1

11.6

CO2W_1

462

TCW_1

13.9

CO2E_2

0

TCE_2

12.2

CO2W_2

749

TCW_2

12.6

CO2E_3

0

TCE_3

10.6

CO2W_3

1213

TCW_3

12.2

CO2E_4

0

TCE_4

9.9

CO2W_4

2167

TCW_4

12.3
  1. soil moisture (TDR)

tonzi

7931AFE

402165

574B4B

402FF3

574632

7A432E

7A3C6E

7A3B40

7A4AAA

26-Dec-06

360










SM









0-15

15.9

14.3

32.5

22.3

20.3

21.4

23.8

19.4

11.2

15-30

16.4

23.7

35.5

32.7

35.0

18.1

28.5

29.2

7.5

30-45

18.8

9.8

38.5

23.9

15.1

12.6

19.0

23.5

14.0

45-60

15.3

5.9

8.8

10.5

12.1

10.7

11.9

19.1

10.7












A6D882B

A3D04E8

A6D72F5

















0-15

32.9

28.2

13.5







15-30

20.6

25.2

29.2







30-45

26.5

29.3

16.8







45-60

15.3

10.5

3.9

















vaira

57318a

7933dee








0-15

10.9

16.7








15-30

21.2

28.8








30-45

21.2

25.6








45-60

18.7

23.3


















  1. Close gate and set up fence.





Tonzi




Dendrometer







Date

Day

Tag #

Reading (cm)

12/26/2006

360

71

22.6



72

23.5



77

Broken



78

Broken



79

23.3



245

23.6



248

25.0



250

21.9



255

22.0



‌252‌

missing



102

Broken

Field Data

No tank data

No TZ Well data found

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

No data found for TZ_fflux.
8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

No data found for TZ_tram.
No data found for TZ_co2prof.
No data found for TZ_irt.
1 TZ_windprof graphs found

Wind Speed Profile

No data found for TZ_tflux.
2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met