Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2017-08-09 09:20:00 | 2017-09-06 10:30:00-->
Other sites visited today: Twitchell Alfalfa | Sherman Wetland | East End | Bouldin Alfalfa

Bouldin Corn: 2017-08-23 10:55:00 (DOY 235)
Author: Daphne Szutu
Others: Elke Eichelmann, Kyle Hemes

Summary: Regular data collection/cleaning, LAI, clip plots/veg height, updated LI-7550 software to v8.7.5, LI-7700 wash hopefully works now, we didn't know gate lock combo

2017-08-23
Bouldin Corn

We arrived at 10:55. It was sunny and clear with a light breeze. It was hazy near the horizon and warm. The gate from the highway (by the overpass) was locked. None of the usual combinations worked. Dan from O.C. Jones called contacts on our behalf, but none knew the new combo.

Kyle and Elke took veg height measurements and clip plot biomass samples.

I took LAI measurements. I set up one wand on a tripod as the above/reference measurement, and used the other wand to take scattering data ("BC0823SC") and LAI data with 10 above and 10 below measurements("BC0823") walking N in the field from the tower. I computed the data on the console and LAI~3.4.

I collected met, camera, and Licor GHG data. I upgraded the 7550 interface sn AIU-1570 from v8.0.0 to v8.7.5. I confirmed the 7550 time, time zone, sonic analog settings, and CO2 and CH4 logging config.

I cleaned the rad and EC sensors.

LI7500 readings:
(v. 8.0.0 --> v. 8.7.5)
CO2 402.2 --> 403.5 umol/mol
H2O 762.8 --> 767.7 mmol/m3
T 26.3 --> 26.7 C
P 100.9 --> 100.9 kPa
SS 99.3 --> 100.2 after cleaning

LI7700 readings:
CH4: 1.82 --> 1.96 after cleaning
RSSI: 7.2 -> 71.6 after cleaning

The 7700 wash was not working when we arrived. I tried to manually pump water, and the pump started up for 1s before turning off again. I disconnected the power cable and water hose from the wash box; some of the water leaked out. I reconnected the power cable, and tried to manually pump water. Again, the pump started up and a small squirt of water came out of the water hose connection before the pump turned off. I manually cleaned the 7700 before I re-attached the water hose, re-started the 7700 software, and then magically the manual water pump and mirror spin worked again. I confirmed the advanced cleaning settings.

We left at 11:45.

Veg Height (cm): Tape measure from ground to top of plant
288, 266, 285, 300, 294, 272, 286, 310, 316, 301, 330, 321, 329, 330, 313, 322, 314, 338, 330, 327, 316, 321, 232, 281, 290, 279, avg = 303.5, stdev = 25.14

0 photos found

Graphs display:
6 sets found

17 BC_met graphs found

Battery Voltage

Soil Heat Flux

Temperature

Solar Radiation

Air Pressure and RH

Soil Moisture

Bouldin Corn PAR

NDVI channels

PRI Channels

Soil Temperatures Set A

Soil Temperatures Set B

Soil Temperatures Set C

SRS NDVI and PRI

Surface Temperature

Forced Diffusion CO2

Forced Diffusion Soil CO2 Flux

Surface Temperature

5 BC_flux graphs found

LI-7500 CO2 and H2O

7700 CH4 and RSSI

Wind

Counts

CO2 in ppm

Can't check TATWBABCSB_cam
Can't check MBSWEEWPBCBA
No data found for BC_pa.
No data found for BC_arable.

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.