Field Notes

<--2017-01-26 09:25:00 | 2017-02-14 10:15:00-->
Other sites visited today: Vaira | Tonzi | Sherman Wetland | West Pond | East End | Twitchell Rice | Twitchell Alfalfa

Mayberry: 2017-01-31 12:30:00 (DOY 31)
Author: Elke Eichelmann
Others: Sam Chamberlain

Summary: Regular data collection, swapped LI7500, serviced water sensors

Arrived at 12:30. It was cold and hazy, the dense fog we observed earlier in the day was starting to clear up a little, but it was still hazy and overcast. Looks like Mayberry had some blow dwn of vegetation as well, like the other wetlands. The canopy height looks shorter than in the past, but it is not quite as obvious a difference as at East End or East Pond.

The wash water reservoir was still full. We did not add any water.
Cleaned radiation sensors, cleaned EC sensors.
Collected USB GHG data, collected met data and camera pictures.

AirT read 44.83 and RH read 49.9, both these readings were off. Maybe they weren’t connected correctly when the datalogger was replaced last week. TCE(7) = NaN. Not sure which level or set this is, but there used to be one TC at the site that always read NaN, maybe it is the same one.
Rnet_tulW and Rnet_watW are both very high (~32000) if this is supposed to be net radiation in W it is wrong. Rnet_tule and Rnet_wat do show more reasonable number for net radiation in W though (~300 to 400).

We collected the conductivity data, collected MiniDOT data and serviced the water sensors. Some of the metal mesh screens on the MiniDOT sensors are corroded and should probably be replaced. Now that the water level is back to normal we should think about putting the additional water CO2 and MiniDOT sensors back out. The top MiniDOT and top two water CO2 sensors were removed when the water level was low since they were the above water table at that time. They should be back below the water table again now.

We swapped the LI7500 for calibration. Li7500 sn 75H-2176 came down, sn 1594 went up. We loaded the new configuration settings and entered the pressure coefficients. We also restarted th LI7550 box to sync up the LI7700 again.
We forgot to write down the readings for the LI7500 before we removed the old head, but the readings with the new head looked fine.

LI7500 readings: sn 75H-1594 (up)
CO2 432.42
H2O 403.5
T 12.62
P 101.90
SS 97.96

LI7700 readings:
CH4: 2.25 → 2.18
RSSI: 71.6 -> 75.9 after cleaning

Left at 13:15.

0 photos found

Graphs display:
11 sets found

7 MB_flux graphs found

Sonic Wind

LI7700 mV signals

Counts

LI7700 CH4 from analog signal

LI7500 CO2 and H2O

LI7700 CH4 from digital signal

CO2 in ppm

No data found for MB_met.
27 MB_tule graphs found

MB Tule Tower: Open Water 2 (3/1/11-3/23/17)

MB Tule Tower: Open Water 1 (3/1/11-2/21/13)

MB Tule Tower: Tule Temps 2 & 3 (3/1/11-3/19/14)

MB Tule Tower: Tule Temps 1 (3/1/11-3/19/14)

Mayberry Tule Tower: Solar Radiation

Mayberry Tule Tower: Disolved Oxygen

Mayberry Tule Tower: IRT and Sensor Temp

Mayberry Tule Tower: Volts and RH

LED NDVI Sensor

Water CO2

Water Pressure

Fluorometer Data

Mayberry pCO2 Profile

Water Temperatures

Air Temperatures

Air Pressure

4-Way Radiometer

MB Tule Tower: Open Water 1 (2/21/13-3/19/14)

MB Tule Tower: Tule Temps 1 (3/19/14-now)

MB Tule Tower: Open Water 1 (3/19/14-now)

MB Tule Tower: Tule Temps 2 & 3 (3/19/14-3/23/17)

MB Tule Tower: Tule Temps 2 (3/23/17-now)

MB Tule Tower: Tule Temps 3 (3/23/17-now)

SRS NDVI Channels

SRS NDVI

Net Radiation

Conductivity

Can't check MBWPEESWGT_mixed
1 MB_cam graphs found

Mayberry Autocam GCC

Can't check MBEEWPSWEPGT_cam
Can't check SIMBTWEE_met
1 MB_minidot graphs found

Mayberry miniDot Dissolved Oxygen

Can't check MBSWEEWPBCBA
1 MB_processed graphs found

Mayberry processed CO2 Fluxes

Can't check MB_fd
1 MB_fd graphs found

Water Forced Diffusion CO2 Flux