Bouldin Alfalfa: 2016-11-22 13:10:00 (DOY 327)
Author: Elke Eichelmann
Others: Kyle Hemmes, Sam Chamberlain

Summary: Regular data collection, reconnected set 3 of soil sensors, adjusted LI7700 heater settings

Arrived at 13:10. It was cloudy/overcast and cool with no wind. Alfalfa was just mowed maybe a couple days ago.

We collected USB GHG data and collected met data. All looks good. We didn’t have a spare CF card with us so we did not collect the camera images.

Sam updated the heater settings for the LI7700 to 15% power top and bottom (up from 5% previously) to help with nightly data loss due to dew.

We clipped the Alfalfa under the radiation sensors and removed the clippings as best as we could.
Refilled wash water reservoir, was half full. Cleaned eddy flux sensors and radiation sensors.

We reinstalled set 3 of ground sensors to the west of the tower, about 1m away from the tower base. The HFP sn 11334 was buried just below ground (0.5 to 1cm depth), the Soil Moisture sensor sn 17135 was buried horizontally at about 2 to 3cm depth. The soil thermocouple rod was also inserted vertically. We cut off the top 1cm of the rod and buried it so that the top TC was at 2cm depth. This way the top of the rod was not sticking out of the soil. We made sure to burry all cables well so hopefully this time they will not get ripped out during mowing.

We connected the new soil sensor set back in the old positions on the datalogger. For the Thermocouples, it was not entirely clear which TC was which. They were connected to the original empty ports but could be in the wrong order.
There was no empty power connector available for the soil moisture probe, so it was connected to the same power as the air pressure sensor. The pressure sensor was disconnected for a short period.

All readings except for the soil moisture were checked after reconnection and all sensors were reading fine. Soil moisture is only measured every 10 minutes or so, so we could not check this.

LI7500 readings:
CO2 425.13 umol/mol
H2O 542.1 mmol/m3
T 18.53 Celsius
P 102.10 kPa
SS 106.77 -> 107.45 after cleaning

LI7700 readings:
CH4: 2.07
RSSI: 45 -> 72 after cleaning

Left at 14:00

Next Mowing: 2017-04-24

0 photos found

Graphs display:
7 sets found

5 BA_flux graphs found

Wind

LI-7500 CO2 and H2O

7700 CH4 and RSSI

Counts

CO2 in ppm

21 BA_met graphs found

Soil Temperatures Set A

Soil Temperatures Set B

Soil Temperatures Set C

Soil Heat Flux

Temperature

Solar Radiation

Air Pressure and RH

Soil Moisture

PAR

PRI Channels

NDVI channels

Battery Voltage

NDVI and PRI

Apogee NDVI

FD Chamber A CO2 and Temp

FD Chamber B CO2 and Temperature

Surface Temperature

Sentek Soil Moisture profile

Sentek Soil Temperature profile

Sentek Soil Salinity profile

Forced Diffusion Soil CO2 Flux

No data found for BA_arable.
Can't check TATWBABCSB_cam
Can't check MBSWEEWPBCBA
2 BA_processed graphs found

Energy

Evapotranspiration

No data found for BA_adex.

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.