Author: Joe Verfaillie
Others: Siyan

Summary: Tram down - brought in, tested tipping bucket, reorganized Floor PSU box, swapped Floor NL511 card reader, leveled radiometers, serviced z-cams, partial Moisture Point.

Tonzi
2013-10-18

I arrived about 10am with Siyan. It was clear, sunny and warm. A light breeze from the south east shifted to the west. The trees here still have leaves but many are brown. Tonzis pond is almost dry.

I tested the tipping bucket by letting 16oz (473ml) of water drip through. It recorded 22.608mm about 11 tips short. Somehow I did the math wrong and only turned the screws a half turn (2 to 3 tips). I need to turn the screws another two turns next time out.

I swapped the Floor NL511 card reader. Sn 6761 went on and sn 9774 came off. I also reorganized the Floors PSU box swapping the metal back plane for a wood one. The sonic and CR100 were down a short bit. During the reorganizing the solder joint on the TX line from the CR1000 to the sonic broke doesnt affect the data.

The tram had derailed trying to drive off the end of the track. I reset it and it moved to park okay, but then didnt run. The battery was okay, but the program was reporting only 10V. I tried to collect data but the data was corrupt. I tried to resend the program but had trouble with that. I reloaded the OS and then the program but there were several versions and I didnt remember which was current. I think V5 is current. The program seemed to run okay but the motors didnt go when the port was set high. We brought the tram in for testing.

I checked the level of the radiometers at the tower top by taping the level to them and putting the arm back in its extended position. They were mostly close to level. I adjusted the BF5 diffuse sensor and the 4channel. The 4channel might need some more work in the north-south direction.

We serviced the z-cams. Last time out z-cam 2 had an acorn in one of its screw holes. This time there was another acorn in a hole. The chance of two acorns falling in the holes is vanishingly small. I bet a woodpecker is stuffing acorns in the holes. I push a piece of fence wire into the acorns to remove them from the holes.

The Moisture Point loggers battery was low and it stopped working. I need to check the connections inside.

Siyan did the standard fieldwork.

Field Data

No tank data

Well Depth

DateLocationDepth (feet)
2013-10-18TZ_floor31.3
2013-10-18TZ_road39.3
2013-10-18TZ_tower36

No TZ Moisture Point data found

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)
2013-10-1810221
2013-10-18217
2013-10-1824512.9
2013-10-18320.1
2013-10-1844
2013-10-18524.5
2013-10-18716.6
2013-10-187215
2013-10-187919.1
2013-10-1888.5

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

3 photos found

BF5 diffuse PAR sensor after leveling
20131018TZ_LevelBF5.jpg ( 2013-10-18 12:10:18 ) Full size: 1592x1228
BF5 diffuse PAR sensor after leveling

NR01 4 channel sensor after leveling
20131018TZ_Level4ChanEW.jpg ( 2013-10-18 13:29:50 ) Full size: 1920x1440
NR01 4 channel sensor after leveling

PAR sensor was level
20131018TZ_LevelPAR.jpg ( 2013-10-18 12:11:00 ) Full size: 964x832
PAR sensor was level

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

11 TZ_soilco2 graphs found

Tonzi Soil CO2 Profile: Open (East) CO2

Tonzi Soil CO2 Profile: Tree (West) CO2

Tonzi Soil CO2 Profile: Open (East) Temperatures

Tonzi Soil CO2 Profile: Tree (West) Temperatures

Tonzi Soil CO2 Profile: Upper CO2

Tonzi Soil CO2 Profile: Lower CO2

Tonzi Soil CO2 Profile: Upper Temperatures

Tonzi Soil CO2 Profile: Lower Temperatures

Tonzi Soil CO2 Profile: Power and Temperature

Tree 2 Soil CO2

Tree 2 Soil Temperature

Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

1 TZ_fflux graphs found

Tonzi Wind Speed

8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

1 TZ_tram graphs found

Tonzi Tram Incoming PAR

3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
No data found for TZ_windprof.
1 TZ_tflux graphs found

Tower CO2 and H2O

2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
8 TZ_osu graphs found

Soil Moisture And Rain

SP1 Solar Radiation

SP1 Soil Temperature Profile

SP1 Soil Heat Flux

SP2 Soil Moisture

SP2 Soil Temperature

SP3 Soil Moisture

SP3 Soil Temperature

No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.