History for PME miniDOT 1219
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
3611 | 2018-07-17 | Lab none | Installed | East End DO Sensor | Turned on and reinstalled with fresh batteries. The water level is very low so the sensor end is just sitting on the muck. |
3603 | 2018-07-12 | East End DO Sensor | Removed | Lab none | Brought back to the lab to replace batteries. |
3250 | 2017-11-10 | Lab none | Installed | East End DO Sensor | Installed at East End hanging from the north side of the scaffolding |
3136 | 2017-09-26 | East End-Temp2 DO Sensor | Removed | Lab none | Removed from East End Temporary Tower 2 - Close Canopy with the decommissioning of the tower. |
3249 | 2017-09-13 | East End DO Sensor | Moved | East End-Temp2 DO Sensor | Moved from the Permanent Tower to the T2 Closed Canopy Temporary Tower |
3247 | 2017-08-02 | East End-Temp3 DO Sensor | Moved | East End DO Sensor | The miniDOT was moved with the Hobo conductivity sensor from the T3 Boardwalk Temporary Tower to the Permanent Tower. |
3246 | 2017-06-23 | Lab none | Installed | East End-Temp3 DO Sensor | Installed at the East End T3 Boardwalk Temporary Tower with the Hobo conductivity sensor. |
2845 | 2017-06-23 | Mayberry DO Sensor D | Moved | East End-Temp3 DO Sensor | Removed MiniDOT (from upper position; it was 1 of 2 sensors in upper position) since water level has been really low and we probably decided 2 sensors was probably enough for a profile. Installed it at EE Temp Tower 3. |
3960 | 2017-05-25 | Mayberry DO Sensor D | Moved | Mayberry DO Sensor D | Moved from static boom (upper position, -10 cm based on water level on 2017-05-10) to floating boom with sn 1221 (upper position, -17 cm). |
3954 | 2017-05-10 | Mayberry DO Sensor F | Moved | Mayberry DO Sensor D | sn 1219 moved from lower position (-68 cm based on water level on 2017-02-23) to upper position (-10cm based on water level on 2017-05-10). All 3 miniDOT sensors (sn 1219, sn 1220, sn 1221) are at this depth for now. |
2635 | 2017-02-23 | Mayberry DO Sensor D | Moved | Mayberry DO Sensor F | Moved from the upper position on the fence post in the channel to the bottom position (-68 cm based on water level at 2017-02-23) on the new water sensor boom. |
3966 | 2016-10-11 | Mayberry DO Sensor E | Moved | Mayberry DO Sensor D | Moved from middle position to upper position (top sensor could not be removed so it was moved to lower position; bottom/lower sensor was removed). |
3958 | 2015-04-23 | Mayberry DO Sensor E | Moved | Mayberry DO Sensor E | Sensor was moved up 10 cm on fence post: from -65 cm (based on water level 2014-10-09) to -50 cm (based on water level on 2015-04-23). |
1603 | 2014-10-16 | Lab none | Installed | Mayberry DO Sensor E | Installed at 66cm below the water surface on the fence post in the channel. |
1600 | 2014-10-09 | West Pond DO Sensor B | Removed | Lab none | Removed from West Pond for installation at Mayberry where a longer profile is possible. |
1587 | 2014-09-25 | Lab none | Installed | West Pond DO Sensor B | Installed at West Pond in a profile at 7.5cm above soil in water column. |
1568 | 2014-09-24 | Lab none | Maintenance | Lab none | Using the miniDOTControl program I set the time and set the sample interval to one minute. |