Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2015-04-09 09:30:00 | 2015-05-07 10:50:00-->
Other sites visited today: Sherman Island | Twitchell Rice | East End | West Pond | Twitchell Alfalfa

Mayberry: 2015-04-23 09:30:00 (DOY 113)
Author: Joe Verfaillie
Others: Patty

Summary: Swapped 7500, service miniDOTs adjusting depths, mux box door may not have been latched.

Mayberry
2015-04-23

I arrived about 9:30 with Patty. It was a mild, sunny day with a cool breeze from the west. The site still looks mostly brown but green (especially tules) is beginning to poke through.

The 7700 read: 2.01ppm CH4, 30.9RSSI – 71 after cleaning, wash reservoir was full

We swapped the 7500 head
Removed sn 75H-2514: 399ppm CO2, 572.5mmol/m3 H2O, 101.6SS, 16.62C, 101.0kPa
Installed sn 75H-2180: 403ppm CO2, 555.1mmol/m3 H2O, 95.9SS, 17.56C, 101.3kPa

We serviced the miniDot/Forerunner profile. The bottom level was probably in the mud. The water depth at the post was 97cm and the bottom level was at 107cm. We moved the bottom level (miniDOT sn 1221) up 15cm to 92cm and moved the middle level (miniDOT sn 1219) up 10cm to 50cm below the water level. The top level (miniDOT sn 1220) is at 25cm below water level. New desiccant packs went into the miniDots. SOMEONE screwed the miniDots together so tight again that I could barely get them apart. There is an o-ring that keeps them water tight. They only need to be snug.
[Edit 2020-04-15 by Daphne: I'm assuming Joe also adjusted the Forerunner/Eosense GP profile and moved the sensors to the same heights as the miniDOT sensors.]

We investigated strange thermocouple readings. The door to the mux box might not have been latched last time. I put desiccant packs in both boxes. I checked terminal screws and found some of the power and control screws on the AM25T turned almost a full turn.

I forgot to bring the atmospheric pressure sensor for reinstall.

0 photos found

Graphs display:
11 sets found

7 MB_flux graphs found

Sonic Wind

LI7700 mV signals

Counts

LI7700 CH4 from analog signal

LI7500 CO2 and H2O

LI7700 CH4 from digital signal

CO2 in ppm

No data found for MB_met.
27 MB_tule graphs found

MB Tule Tower: Open Water 2 (3/1/11-3/23/17)

MB Tule Tower: Open Water 1 (3/1/11-2/21/13)

MB Tule Tower: Tule Temps 2 & 3 (3/1/11-3/19/14)

MB Tule Tower: Tule Temps 1 (3/1/11-3/19/14)

Mayberry Tule Tower: Solar Radiation

Mayberry Tule Tower: Disolved Oxygen

Mayberry Tule Tower: IRT and Sensor Temp

Mayberry Tule Tower: Volts and RH

LED NDVI Sensor

Water CO2

Water Pressure

Fluorometer Data

Mayberry pCO2 Profile

Water Temperatures

Air Temperatures

Air Pressure

4-Way Radiometer

MB Tule Tower: Open Water 1 (2/21/13-3/19/14)

MB Tule Tower: Tule Temps 1 (3/19/14-now)

MB Tule Tower: Open Water 1 (3/19/14-now)

MB Tule Tower: Tule Temps 2 & 3 (3/19/14-3/23/17)

MB Tule Tower: Tule Temps 2 (3/23/17-now)

MB Tule Tower: Tule Temps 3 (3/23/17-now)

SRS NDVI Channels

SRS NDVI

Net Radiation

Conductivity

Can't check MBWPEESWGT_mixed
1 MB_cam graphs found

Mayberry Autocam GCC

Can't check MBEEWPSWEPGT_cam
Can't check SIMBTWEE_met
1 MB_minidot graphs found

Mayberry miniDot Dissolved Oxygen

Can't check MBSWEEWPBCBA
1 MB_processed graphs found

Can't check MB_fd
1 MB_fd graphs found

Water Forced Diffusion CO2 Flux

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.