Equipment and Calibration
View History
Equipment Entry
|
Documents
Calibration: cal_KippZonen_PARLite_sn040412_20040529.pdfReport: PAR comparison 09-2018 - 2018-09-28
Report: Vaira PAR Cross Compare - 2020-06-12
History
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
4802 | 2020-09-16 | Vaira PAR Sensor Incoming Cal | Moved | Vaira PAR Sensor Incoming | Moved from the incoming cal position to the main incoming position. |
4710 | 2020-08-26 | Lab none | Installed | Vaira PAR Sensor Incoming Cal | Installed at Vaira in the incoming position for inter-comparison. This sensor will likely replace the old sensor. |
4713 | 2020-08-05 | Bouldin Corn PAR Sensor Under-A | Removed | Lab none | Removed from under the canopy at Bouldin Corn. The corn has reached maximum growth continued measurements of questionable use. |
4509 | 2020-05-29 | Lab none | Installed | Bouldin Corn PAR Sensor Under-A | I stalled about 10cm above the ground near the picams to measure under canopy PAR |
4024 | 2019-07-25 | Mayberry PAR Sensor Reflected Water | Removed | Lab none | Removed from MB (PAR reflected water) and brought back to the lab for testing (spiky). It was replaced by sn 010161. |
3766 | 2018-10-25 | Lab none | Installed | Mayberry PAR Sensor Reflected Water | Installed at MB (measuring reflected water) to replace sn 010161, which was brought back to the lab for repair/calibration. |
4536 | 2018-09-28 | Lab none | Calibration | Lab none | Calibrated in the lab by sticking it out the south-facing window in Hilgard 205 with the reference sensor sn 161073. The factory calibration was 5.58 µV/(µmol/m2·s) and the new calibration was 5.74 µV/(µmol/m2·s). For details see the RT report "PAR comparison 09-2018" https://nature.berkeley.edu/biometlab/bmetdata/rtreport.php?screen=view&id=14 |
3171 | 2017-10-19 | East End-Temp1 PAR Sensor Reflected | Removed | Lab none | Removed with decommissioning of East End Open Water tower (temporary tower 1) |
2916 | 2017-07-03 | East End-Temp1 PAR Sensor Reflected | Location | East End-Temp1 PAR Sensor Reflected | Checked serial number. |
4313 | 2017-06-14 | East End-Temp1 PAR Sensor Incoming | Moved | East End-Temp1 PAR Sensor Reflected | After having been initially installed in the upward looking, incoming position on the berm, this sensor was moved to a area near open water and mounted in the downward looking, reflected position. |
2893 | 2017-06-01 | Lab none | Installed | East End-Temp1 PAR Sensor Incoming | Installed at the East End Temporary Tower #1 Open Water location with the initial set up of this site. It is facing up measuring incoming PAR |
1835 | 2015-05-12 | Sherman Island PAR Sensor Reflected | Removed | Lab none | Removed with the decommissioning of the Sherman Cow Pasture site. |
42 | 2010-02-05 | Sherman Island PAR Sensor Reflected | Location | Sherman Island PAR Sensor Reflected | Collecting reflecet PAR at Sherman. cal coefficient 5.58 |
1748 | 2007-03-27 | Lab none | Installed | Sherman Island PAR Sensor Reflected | Installed on radiation boom in the downward position to measure reflected PAR |
4074 | 2004-05-29 | Factory | Calibration | Lab none | Initial factory calibration 5.58 uV/(umol/m2/s) |