Sherman Island: 2007-03-27 11:00:00 (DOY 86)
Author: Ted Hehn
Others:

Summary: Setting up the site, installing met sensors

When: Tue, 27Mar07 JD-86
Where: Sherman Island
Who: Ted Hehn
Weather Cool & windy with scattered showers

Trip Purpose Site integration

Methane site:
27Mar07 11:00 PST

Instrument boom structure is 31 5/8 inches wide the cross brace should be cut to 48 inches in length.

Install leveling table on boom arm.

Install
PAR (solar) sn 040411 (5.66 umol/m2/s)
PAR (terrestrial) sn 040412 (5.58 umol/m2/s)

Install
4 band radiometer sn 020476 (10.27 uV/W/m2, R0/Rs = 1.0050)

Install net radiometer.

Install T &RH sensor leads. The sensor is 265 cm above grade

Install Druck water level pressure sensor. The sensor is 75 cm below grade.

Misc Notes

Field kit
Cooler
Aloevera
Gloves
Baby wipes
Water
Radio
Trail mix
Insect repellant
Sun block
Paper towels
Lighter
matches

make 4 – 6 inch pipe collars for soil moisture probes at SI