Instrument:Data Logger
Manufacture:Campbell Sci.
Model No:CR1000
Serial No:47108
Tag No:
Acquisition Date:2012-03-12
Project:DWR-Wetland
Location on 2020-07-09:Loaned,
Notes: Wiring panel No. 40322

Documents

PackingSlip: ps_Campbell_20120312.pdf

History

Rec No.DateLoc FromTitleLoc ToNotes
4591 2020-07-09 Loaned Disposed Disposed Given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
4561 2020-07-09 Sherman Barn Data Logger Met Removed Loaned none Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
3983 2019-05-28 Sherman Barn Data Logger Met Notes Sherman Barn Data Logger Met VX2 may be unreliable. NR01 PRT was drifting constantly until it was re-wired from VX2 to VX3, but that could also have been a wiring issue with another channel.
3856 2019-01-24 Sherman Barn Data Logger Met Serviced Sherman Barn Data Logger Met Changed Pakbus address from 1 to 8.
3572 2018-07-11 Lab none Installed Sherman Barn Data Logger Met Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
3491 2018-06-21 Lab none Upgrade Lab none Upgraded OS from 31.08 to 32.02. I reset the networking settings (IP address = 192.168.2.100, enabled FTP with Tower/biomet).
3512 2018-06-13 Twitchell Alfalfa Data Logger Met Removed Lab none Removed with Twitchell Alfalfa site decommissioning.
2992 2017-08-23 Twitchell Alfalfa Data Logger Met Upgrade Twitchell Alfalfa Data Logger Met The OS was upgraded from probably v24 to v31.08. OS v31.08 is FAT32 and reset the CR1000 to factory settings.
1009 2013-05-24 Lab none Installed Twitchell Alfalfa Data Logger Met Installed in the box at the Alfalfa tower to collect data from soil sensors and the HMP60 sn G4540021
1015 2013-05-15 Vaira Removed Lab none This CR1000 was removed from Vaira along with NL115 sn 6761 where they were used to collect images from the Starsot Phenocam. They were replaced by a Raspberry Pi
911 2013-01-24 Lab none Installed Vaira Installed the the computer box with NL115 sn 6761 to collect images from the Phenecam
844 2012-11-08 West Pond Data Logger ATI Removed Lab none Removed from West Pond with the ATI sonic after a three week inter-comparison
824 2012-10-18 Lab none Installed West Pond Data Logger ATI Installed in the box that Robin supplied with the ATI sonic at West Pond. This CR1000 is setup to collect the serial stream from the ATI sonic for a comparison.