Equipment and Calibration

View History

Equipment Entry

Instrument:CO2 Probe
Manufacture:Vaisala
Model No:GMP222
Serial No:Z2720013
Tag No:
Acquisition Date:0000-00-00
Project:DOE-TCP
Location on 2016-02-04:Lab, -2cm
Notes: 0-1% range

Documents

No documents found

History

Rec No.DateLoc FromTitleLoc ToNotes
2161 2016-02-04 Tonzi CO2 Probe Tree1 Profile -0.04 Removed Lab none Removed from Tonzi Tree profile at -4cm for calibration
2074 2014-12-09 Tonzi CO2 Probe Tree1 Profile -0.04 Location Tonzi CO2 Probe Tree1 Profile -0.04 Tonzi Tree1 profile at -4cm
2022 2014-03-18 Tonzi CO2 Probe Tree1 Profile -0.02 Moved Tonzi CO2 Probe Tree1 Profile -0.04 At Tonzi in the Tree 1 profile this probe was moved from the -2cm location to -4cm
1993 2014-01-29 Lab none Installed Tonzi CO2 Probe Tree1 Profile -0.02 Installed at Tonzi in the Tree 1 profile at -2cm with new U-shaped tops on the PVC enclosures
1430 2014-01-27 Lab none Calibration Lab none Trueppm = Probeppm*1.327 + 209.8; linear relationship between the ppm reported by the probe and the known ppm of the calibration tanks. Tanks: zero air (0ppm), 3056ppm, and 10000ppm. Ta=22.7C, P=102.1kPa. Because the lab conditions were close to factory conditions, no temperature or pressure corrections were applied. Done by: Patty.
1178 2014-01-24 Tonzi CO2 Probe Tree1 Profile -0.02 Removed Lab none Removed from Tonzi tree #1 at -2cm for lab calibration
1130 2012-02-16 Lab none Installed Tonzi CO2 Probe Tree1 Profile -0.02 Installed at Tonzi in the Tree1 set at -2cm
1405 2012-02-06 Lab none Calibration Lab none Trueppm = Probeppm*1.043 + -24.84; linear relationship between the ppm reported by the probe and the known ppm of the calibration tanks. Tanks: zero air (0ppm), 436ppm, 2238ppm, and 10000ppm (N2 bal). Ta=24.2C, P=101.5kPa. Because the lab conditions were close to factory conditions, no temperature or pressure corrections were applied. Done by: Siyan.
1370 2010-03-02 Lab none Calibration Lab none Trueppm = Probeppm*1.062 + 17.07; linear relationship between the ppm reported by the probe and the known ppm of the calibration tanks. Tanks: zero air (0ppm), 383ppm, 597ppm, and 2238ppm. Ta=22.2C, P=101.5kPa. Because the lab conditions were close to factory conditions, no temperature or pressure corrections were applied. Done by: Jaclyn.
4635 2010-01-08 Tonzi CO2 Probe Open Profile -0.02 Location Tonzi CO2 Probe Open Profile -0.02 Pulled out for ambient air reading and put back.
4545 2008-03-06 Lab none Installed Tonzi CO2 Probe Tree1 Profile -0.02 Installed in the Wast under tree profile at -2cm. mV and ppm readings in air were recorded before installation.