Equipment and Calibration
View History
Equipment Entry
|
Documents
No documents found
Report: Tonzi Tower Eddy System Compare - 2017-05-11
History
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
5361 | 2021-07-06 | Borrowed none | Returned | Lab none | Returned from FLEXLAB at LBL by Hershow Al-Barazi - Cable to be returned later hopefully. |
4474 | 2020-05-22 | Lab none | Loaned | Loaned none | Loaned to Rod Mobini <rmobini@lbl.gov> at LBL FLEXLAB for an experiment on the indoor spread of droplets related to COVID-19 over the summer. The sonic was cleaned and tested okay in the lab. The settings were standardized to: B3 = 9600 baud E1 = Full duplex F1 = 8 data, no parity G1 = No averaging J2 = Two differential inputs J5 = Zero single ended inputs L1 = <cr><lf> M1 = UVW ASCII message NA = Name 'A' O1 = comma separated P6 = 10Hz U1 = m/s Z1 = Not used X1 = align to axis |
4198 | 2019-11-25 | Loaned | Returned | Lab none | Returned by David R. Cook at Argonne National Laboratory. |
3484 | 2018-06-19 | Lab none | Loaned | Loaned | Loaned to David R. Cook at Argonne National Laboratory for a year or so. Two other sonics sn 000022, sn 000023 and a PSU sn 000193 went too |
2786 | 2017-05-24 | Tonzi-Tower | Removed | Lab none | Removed from the Tonzi Tower. Replaced by the new Licor GHG system from Ameriflux. |
1801 | 2015-04-29 | Lab none | Installed | Tonzi-Tower | Installed on the Tonzi Tower to replace sn 000021 that has been having trouble with the serial stream dropping out. |
551 | 2012-04-24 | Mayberry Anemometer | Removed | Lab none | Removed from the Mayberry eddy tower. Replaced with WM sonic sn 074417 |
1755 | 2011-04-26 | Lab none | Installed | Mayberry Anemometer | Installed on the Mayberry tower to replaced sn 000022 that had stopped sending data. |
4761 | 2010-07-01 | Sherman Island-Levee Anemometer | Removed | Lab none | Removed from levee site due to theft of everything else. |
4758 | 2010-04-06 | Sherman Island Anemometer 2ndTower | Moved | Sherman Island-Levee Anemometer | Moved along with the secondary tower from the Sherman cow pasture to the Sherman Levee location. |
4757 | 2009-06-26 | Lab none | Installed | Sherman Island Anemometer 2ndTower | Installed the the secondary tower to replace sn 074417 which has a firmware issue that reduces the response rate of the SOS/T channel. |
4912 | 2003-05-30 | Tonzi-Floor Anemometer Floor | Removed | Lab none | Removed from Tonzi-Floor due to no data. On power up it would send some data and then quit. |
4893 | 2003-01-07 | Lab none | Installed | Tonzi-Floor Anemometer Floor | Installed at Tonzi-Floor to replace sn 000021. |
2098 | 2001-01-05 | Vaira Anemometer | Removed | Lab none | Removed from the Vaira Tower due to going off scale at midday. Replaced by sn 000024 |
2097 | 2000-10-22 | Lab none | Installed | Vaira Anemometer | Installed on the Vaira Tower with the initial setup of the site. |