Field Notes
<--2025-01-09 10:50:00 |Other sites visited today: Vaira
Phenocam link: Searching...
Tonzi: 2025-01-22 11:20:00 (DOY 22)
Author: Joe Verfaillie
Others: Kuno
Summary: Mild and dry, standard fieldwork, not much happening, reset tree 5 dendrometer, removed old co2 profile solenoid box, tried to update RevBowen code on floor and tower met.
Tonzi 2025-01-22 Kuno and I arrived at about 11:20 PST. It was mostly clear and sunny with a steady breeze from the west at the tower top. Almost no breeze on the ground. This has been a long dry period since the beginning of the month (about 20 days). The puddles on the road are mostly gone. There are lots of cow hoof prints around but all the fences seem to have held. The grass is still short and the tips have yellowed with cold and or dryness. I collected the tower top data: flux and camera data and cleaned the radiometers. The wash reservoir was full. The 7500 read: 443.1ppm CO2, 257.1mmol/m3 H2O, 11.3C, 100.3kPa, 99.9SS - 100.4 after cleaning The 7700 read: 2.12ppm CH4, 37.2RSSI - 86.1 after cleaning I did the manual soil moisture, well depths and DBH, I collected the FD data and serviced the zcams. I reset the DBH band on tree #5 it was almost off scale. I collected the Floor flux and well data. I collected the tree bole temperature data - about 6C difference from south and north sides of the trees. The wash reservoir was full. The 7500 read: 437.2ppm CO2, 276.4mmol/m3 H2O, 14.1C, 100.4kPa, 101.4SS - 102.4 after cleaning The 7700 read: 2.11ppm CH4, 64.6RSSI - 85.3 after cleaning The Floor 7700 needs new desiccant - it has been reading about 31% since before the last visit! At least the water vapor in the air has been low - cold and dry. Kuno did his usual rounds of flux chambers on the tree trunks and soil collars. He also did some Pine trunks and a couple more possible ant mounds - pretty much all zero - cold and dry. I removed the solenoid box from the old CO2 profile system on the tower. This required tracing a bunch of wires that went up the tower and one that was plugged into the power strip in the solar controller box. I'm pretty sure that power plug was only giving power to the unused solenoid box so I removed it along with the box. Some of the long wires running up the tower I left in place. More work to be done. I tried to update data logger programs on the Tower and Floor for the reverse Bowen ratio method. The calculations being used did not match the ones I had recently sent to Carlos, but I'm still unclear which ones are correct. Need to ask Carlos. We left at about 14:50 PST |
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
No data found for TZ_soilco2.
Can't check TZ_mixed
3 TZ_mixed graphs found
1 TZ_fflux graphs found
8 TZ_fmet graphs found
No data found for TZ_tram.
3 TZ_co2prof graphs found
1 TZ_irt graphs found
No data found for TZ_windprof.
1 TZ_tflux graphs found
8 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
8 TZ_osu graphs found
3 TZ_fd graphs found
Tonzi Z-cam data