Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2010-12-09 12:30:00 | 2011-01-05 13:55:00-->
Other sites visited today: Sherman Island | Mayberry

Twitchell Rice: 2010-12-21 08:00:00 (DOY 355)
Author: Joe Verfaillie
Others:

Summary: Problems with AC power in the box, shutdown generator to await fix after first of the year, HMP45 not working.

Twitchell
12/21/2010

I arrived about 8am. The new gravel on the crossing at the north is great. The road along the side of the field was just passable is a small car. It was cool and windy with the wind from the east-southeast. I could smell the generator at the tower. It was overcast with some fog here and there, but looked to be clearing. No birds in sight. There were lots of sheep or deer droppings on the ground near our site. Also there were some shotgun shells on the ground to the north of the box.

The generator was running, but all the AC equipment in the box was cold and dark. There was a little bit of water in the bottom left corner of the box that had gotten the power strip wet. The air conditioner plug had a green light indicating power but would not turn on and did not seem to reset. The power strip showed 150VAC. Everything but the air conditioner is rated to 220 so should be able to handle it.

The LGR had a blown fuse in its power plug. I replace the fuse and disconnected the external pump. Upon plugging it in, it lugged the generator slightly and blew the new fuse. I’m not sure what is wrong with it, if anything, and I don’t know what is wrong with the air conditioner. It’s not something I can fix before the holidays, so I told Jim we won’t need the generator until mid-January and shut down the generator. The LGR’s intake tubing had also broken inside the box.

The computer seemed to have a full battery and the rest of the system was running on solar. Batteries: 12.3V, solar 0.9A, load 0.8A. I swapped the CR1000 card and let the computer collect the latest data. Then I shut down the computer to save its battery while the generator is down.

The fan on the HMP45 was not working so I disconnected it in case it was pulling some power. The HMP45 wasn’t working either, its wiring was okay, but zero voltages on output. The sensor elements were clean and dry. I left it in place.

I picked up our inverter that was left by the big generator when we stopped using the DC sign generator.

The tipping bucket and radiometers were clean.

0 photos found

Graphs display:
6 sets found

12 TW_met graphs found

Soil Heat Flux

Solar Radiation

Air Temperature

Soil Temperature Set 1

Soil Temperature Set 2

Soil Temperature Set 3

Water Temperature

RH and Pressure

Soil Moisture

Rain and Water Level

Disolved Oxygen

LED NDVI Channels

5 TW_flux graphs found

Sonic Anemometer Winds

LI7700 CH4 and RSSI

Twitchell CH4

LI7500 CO2 and H2O

Twitchel Rice Flux Counts

Can't check TWSI_mixed
Can't check SIMBTWEE_met
No data found for TW_cam.
Can't check TATWBABCSB_cam

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.