Field Notes
<--2015-04-06 10:30:00 | 2015-04-15 10:00:00-->Phenocam link: Searching...
Tonzi: 2015-04-08 10:30:00 (DOY 98)
Author: Joe Verfaillie
Others: Ana
Summary: Installed wind profile, swapped 7500s, swapped MP probe, Tower computer okay, Tower sonic not working, tree hit be lightning.
Tonzi 2015-04-08 I arrived about 10:30 with Ana. It was cool and breezy with a few clouds. A tree near Tonzi’s house looks like it got hit by lightning. It was split down the center and the main trunk was completely stripped of bark. The big plastic cow water container was sitting in the road – we moved to the side. Seems like Tuesday’s storm was windy with lightning. The ground was wet, but not muddy in most places. Ana and I worked of setting up a wind profile with the old Handar 2D sonics. We set up a guyed post near the floor tower in the stand of tree to the south east. Installation went well and it was running. We need to check the level of a couple of the sonics and the headings. A CR1000 sn 66250 and NL115 sn 13053 (not used) are in the box to collect the data. sn 0846 – 7.56m sn 0843 – 5.42m sn 0860 – 3.89m sn 0839 – 2.0m (approx.) sn 0852 – 1.2m (approx.) sn 0854 – 0.1m (approx.) I swapped the 7500 on the Floor site – sn 0041 came off and sn 0073 went on. I restarted the Floor computer. It was being slow and not getting the serial data from the sonic – however the CR1000 seemed fine. I also swapped the 7500 on the Tower – sn 1594 came off and sn 0035 went on. I swapped the Moisture Point probe near the Tower. Sn 000007931AFE was pulled and has a broken pin second from bottom. Probe sn 00000128B8072 went in the same hole. The computer at the Tower was still beeping as Siyan reported. However, a hard restart worked and it booted up okay. I left it running. We swapped the desiccant in the BF5 sensor. It had a puddle in the bottom of its enclosure and significant condensation inside. The sonic on the Tower was not working. I checked all connections and cycled power. I pulled the sonic off the Floor tower to swap in, but when I took the connector off the bottom on the Tower sonic, I notice that the wires were all rotted and frayed with one black wire completely disconnected. I will need to go back out next week with a replacement sonic, cable and RS422/232 converted box just in case. |
Field Data
No tank data
No TZ Well data found
No TZ Moisture Point data found
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
No TZ Tree DBH found
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
3 photos found
20150408TZ_WindProfile.jpg ( 2015-04-08 14:36:34 ) Full size: 1920x1440
Six level wind speed profile within the canopy
20150408TZ_LightningStrike.jpg ( 2015-04-08 15:39:23 ) Full size: 1920x1440
Oak tree that was hit by lightning
20150408TZ_AnaWindProfile.jpg ( 2015-04-08 12:15:15 ) Full size: 1920x1440
Ana working on under canopy wind profile in green woodland
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
11 TZ_soilco2 graphs found
Can't check TZ_mixed
3 TZ_mixed graphs found
1 TZ_fflux graphs found
8 TZ_fmet graphs found
1 TZ_tram graphs found
3 TZ_co2prof graphs found
No data found for TZ_irt.
No data found for TZ_windprof.
1 TZ_tflux graphs found
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
8 TZ_osu graphs found
No data found for TZ_fd.
Tonzi Z-cam data