Field Notes
<--2010-03-21 11:30:00 |
2010-04-13 10:00:00-->
Phenocam link:
Searching...Tonzi/Vaira: 2010-04-02 06:00:00 (DOY 92)
Author: Siyan Ma
Others:
When: Date: 4/2/2010 , Day: 92 , Watch Time: 6:00 am .
Where: Tonzi/Vaira Ranch
Who: Siyan
Weather:
cloudy, slight wind, a lot of dews, started raining at noon.
Phenology:
green grass, green oak leaves expanding
Tonzi
|
|
|
Summary
- Pre-dawn leaf water potential: oak leaf= -3.4 bar; pin needle=-6.1
bar.
- Power showed “OFF” at Vaira.
- calibrated Li-800 in the field.
- collected samples of oak leaves and pin needles
- dendrometers
- soil moisture
- groundwater well:
Date
|
DOY
|
Location
|
Depth
from NO black thing (feet)
|
4/2/2010
|
92
|
Floor
|
23.30
|
|
|
Tower
|
27.62
|
|
|
roadside
|
31.75
|
Vaira_Grass
Site
- Fence and gate power: 12 v.
- Panel and Batteries: 13.5 v; 0.0 amps; OFF amps.
NO POWER! NO RUNNING!
- Check levels of Radiation
sensors, clear up surfaces. YES!
- Check rain gage, make sure
not clogged. YES!
- Closed gate and set up fence.
YES!
Tonzi_Tower Site
- Fence and gate power: 12 v.
- Panel and Batteries: 12.7
v; 0.0
amps; 3.7
amps.
- Reading from Gillsonic screen
before downloading data. (The
value of H2O and CO2 should be in the range of 0 – 5
v.)
- downloading data NO!
- check the fans of air temp.
and relative humidity sensors on the tower and the floor. NO!
- Check rain gage, make sure not
clogged. YES!
- Check calibration cylinders;
CO 2 700 psig; flow 30 psi; 418.8
ppm.
N 2 300
psig; flow 20
psi.
Manually calibrate Li-800. Following Ted’s instruction: H:\IoneSavanna_2004\Tower_2004\CO2Profile\LI800_Calibration_Procedure_2Nov04.txt
Is the pump running Pump wasn’t
working. Click it and it worked.
before zero 4.6 ppm
after zero
before span
after span
- close gate and set up fence. YES!
Toniz_Floor
Site
- Fence and gate power: 12 v.
- Panel and Batteries: 12.3 v; 1.5
amps; 1.9
amps. (about
7:00 am local time)
- Reading from Gillsonic screen
before downloading data. (The
value of H2O and CO2 should be in the range of 0 – 5
v.)
LOOKS
OK, BUT THE POWER DIDN’T ALLOW ME TO SAVE “PRINT SCREEN” .
- downloading data NO!
- Check MD-9 system
connections NO!
- Soil CO2 profile:
no power when I got there. I
unplug and re-plug fuses, then the system back to work.
Reading
from panels of analyzers
depth
|
Open
|
order
|
depth
|
Tree
|
order
|
2cm
(1%)
|
1320
|
1
|
2cm
(1%)
|
3270
|
1
|
4cm
|
1560
|
2
|
4cm
|
3700
|
4
|
8cm
|
2280
|
3
|
8cm
|
3600
|
2
|
16cm
|
1210
|
4
|
16cm
|
8420
|
3
|
- Close gate and set up fence. YES!
tonzi
|
7931AFE
|
402165
|
574B4B
|
402FF3
|
574632
|
7A432E
|
7A3C6E
|
7A3B40
|
7A4AAA
|
4/2/2010
|
92
|
|
|
|
|
|
|
|
|
|
sm
|
|
|
|
|
|
|
|
|
0-15
|
39.6
|
17.3
|
39.3
|
29.4
|
32.3
|
26.7
|
23.2
|
21.4
|
16.8
|
15-30
|
37.9
|
30.1
|
37.4
|
34.1
|
34.7
|
24.9
|
26.1
|
29.5
|
16.4
|
30-45
|
39.9
|
41.9
|
42.1
|
37.4
|
43.5
|
27.6
|
26.5
|
31.0
|
32.4
|
45-60
|
38.5
|
55.1
|
62.9
|
49.7
|
42.0
|
32.8
|
36.8
|
46.6
|
28.2
|
|
|
|
|
|
|
|
|
|
|
|
A6D882B
|
A3D04E8
|
A6D72F5
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0-15
|
26.7
|
17.9
|
19.1
|
|
|
|
|
|
|
15-30
|
25.2
|
13.6
|
31.9
|
|
|
|
|
|
|
30-45
|
33.8
|
29.3
|
40.7
|
|
|
|
|
|
|
45-60
|
40.8
|
45.4
|
42.3
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
vaira
|
57318a
|
7933dee
|
|
|
|
|
|
|
|
0-15
|
21.5
|
12.7
|
|
|
|
|
|
|
|
15-30
|
23.7
|
24.0
|
|
|
|
|
|
|
|
30-45
|
19.0
|
26.5
|
|
|
|
|
|
|
|
45-60
|
35.7
|
34.0
|
|
|
|
|
|
|
|
Tonzi
|
|
|
|
|
|
Dendrometer
|
|
|
|
|
|
|
|
|
|
|
Date
|
Day
|
Tag #
|
Reading (mm)
|
|
|
4/2/2010
|
92
|
72
|
7.5
|
|
|
|
|
79
|
10.9
|
|
|
|
|
102
|
X
|
|
|
|
|
245
|
10.1
|
|
|
|
|
250
|
21
|
(reset to 10.5 on May 7, 2009)
|
|
|
|
1
|
18.1
|
|
|
|
|
2
|
9.9
|
|
|
|
|
3
|
16.2
|
|
|
|
|
4
|
7.4
|
|
|
|
|
5
|
10.5
|
|
|
|
|
7
|
14.9
|
133
|
|
|
|
8
|
16.6
|
11828
|
|
|
|
71
|
X
|
|
|
|
|
77
|
X
|
|
|
|
|
78
|
X
|
|
|
|
|
248
|
X
|
broken
|
|
|
|
255
|
X
|
|
|
|
|
252
|
X
|
|
|
|
|
6
|
X
|
|
|
Notes:
“X” means not working any more.
Dendrometers
installed by Gretchen group
|
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
11 TZ_soilco2 graphs found
Can't check TZ_mixed
3 TZ_mixed graphs found
No data found for TZ_fflux.
8 TZ_fmet graphs found
1 TZ_tram graphs found
3 TZ_co2prof graphs found
No data found for TZ_irt.
No data found for TZ_windprof.
No data found for TZ_tflux.
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
No data found for TZ_osu.
No data found for TZ_fd.