Bouldin Corn: 2024-12-19 13:10:00 (DOY 354)
Author: Daphne Szutu
Others: Kyle

Summary: Cold and foggy, no met data since 2024-12-11--fixed after removing shorted water level sensor, field is flooded

2024-12-19
Bouldin Corn/Sorghum

Kyle and I arrived at 13:10 PST. It was cold and foggy. We had a big storm last week and more rain coming all next week. Our field and all of surrounding fields are flooded. Kyle went to go look at the drain in the southeast corner of the field and confirmed that water was flowing out of the field. There was no water at the surface under the tower, but I could see a puddle forming around the edges of the well pipe, so the water is probably just under the surface.

Charlotte was also on site, on the phone with Campbell Sci when we arrived. She was here yesterday and all of her ground sensors were reporting NAN, so she was back today to troubleshoot them. She was wondering what our soil sensors measure and if she could use them to gap fill her data.

I opened our met enclosure and could hear a high-pitched squealing sound which usually means something is shorting. I unplugged everything from the power strip, which stopped the squealing sound. I powered just the datalogger to download data. No met data since 2024-12-11. I started plugging the sensors back into the power strip one by one. The water level sensor is the one that was shorting, which is too bad because now is the main time of the year we need water level data. Kyle removed the sensor sn ?? and confirmed that the black, outside cable is cracked. All the other data seemed fine.

I also downloaded met, cam, and PA data. Kyle cleaned flux and rad sensors. I’m not sure if she checked the precip bucket here.

7500 read: 441ppm CO2, 449mmol/m3 H2O, 10.1C, 102.1kPa, 100SS--100 after cleaning
7700 read: 2.26ppm CH4, 43RSSI – 78 after cleaning

We left at 13:55 PST.

Looking at the data back in the lab, there's something wrong with the sonic data starting around the same time as the water level sensor shorted and we lost met data. Tsonic stays around 5C. The 7500/7700 data seem ok though.

0 photos found

Graphs display:
6 sets found

17 BC_met graphs found

Explore the graph:Battery Voltage in a new window

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Temperature in a new window

Explore the graph:Solar Radiation in a new window

Explore the graph:Air Pressure and RH in a new window

Explore the graph:Soil Moisture in a new window

Explore the graph:Bouldin Corn PAR in a new window

Explore the graph:NDVI channels in a new window

Explore the graph:PRI Channels in a new window

Explore the graph:Soil Temperatures Set A in a new window

Explore the graph:Soil Temperatures Set B in a new window

Explore the graph:Soil Temperatures Set C in a new window

Explore the graph:SRS NDVI and PRI in a new window

Explore the graph:Surface Temperature in a new window

Explore the graph:Forced Diffusion CO2 in a new window

Explore the graph:Forced Diffusion Soil CO2 Flux in a new window

Explore the graph:Surface Temperature in a new window

5 BC_flux graphs found

Explore the graph:LI-7500 CO2 and H2O in a new window

Explore the graph:7700 CH4 and RSSI in a new window

Explore the graph:Wind in a new window

Explore the graph:Counts in a new window

Explore the graph:CO2 in ppm in a new window

Can't check TATWBABCSB_cam
Can't check MBSWEEWPBCBA
2 BC_pa graphs found

Explore the graph:Purple Air Met Data in a new window

Explore the graph:Purple Air Particulate Matter in a new window

1 BC_arable graphs found

Explore the graph:Temperatures in a new window