Summary: Power up and debug on rebuilt met system
24Jul04 Install power leads and wiring for mux control. Install new program and fire up the new system. FAILURE most values are negative. Begin diagnostic procedures using initial sequence that reads the 15 soil profile thermocouples. This indicated that I had the control wiring for the 2 muxs interchanged. Correct this and all looks great but 7 values are bad: 4 way PRT temp, NDVI and 5 soil moisture values. Correct wiring for these PRT and NDVI and they come on line. The soil moisture probes do not have power yet. Note that the first thermocouple on the soil profile reading 25 when the other surface temps are reading 35. |