Skip to main content
rice field banner biometlab logo
   
   
 
   
   
   
   
   
 
 

Field Notes

<--2014-12-09 11:00:00 | 2015-01-07 10:00:00-->
Other sites visited today: Twitchell Rice | Twitchell Alfalfa | West Pond | Mayberry | East End | Sherman Island

Tonzi: 2014-12-23 09:00:00 (DOY 357)
Author: Siyan Ma
Others:

Summary: Ponds are full, swapped 7500s at Tonzi, Brought in LI-820, Tower sonic hung up again.


When: Date: 12/23/2014 , Day: 162 , Watch Time: 9:00 am .
Where: Tonzi/Vaira Ranch
Who: Siyan
Weather: clear, sunny
Phenology: ponds full

image001.jpgimage002.jpgimage003.jpgimage004.jpg

Summary
  1. Swapped memory cards of CR1000s at Tower and Floor. Tower, sn 1594 on, sn 0976 off; Floor, sn 0041 on, sn 0042 off.
  2. Checked and downloaded winflux and met data from PC at Tower and Floor. Tower Sonic stops working on day 351.
  3. The CO2 profile system wasn’t calibrated on site due to failure of IRGA. Turn off co2profile, take home IRGA
  4. Read dendrometers
  5. Measured soil moisture
  6. Measure groundwater well


Vaira_Grass Site
  1. Downloaded Phenocam images.
  2. Swapped the memory cards of CR1000.
  3. Checked the fans of air temp and relative humidity sensors at Vaira. YES!
  4. Downloaded met data and soil CO2 profile data:

image005.jpg

image006.jpg
  1. Checked levels of Radiation sensors, clear up surfaces. YES!
  2. Checked rain gage, make sure not clogged. YES! Rain gage needs a net cover.
  3. Closed gate and set up fence. YES!

Tonzi_Tower Site

  1. Fence and gate power: <12 v, probably because wires touched a shrub branch or ground. Walked along and didn’t see anywhere broken.
  2. Swapped Li-7500s. Tower, sn 1594 on, sn 0976 off.
  3. downloaded Winflux data from PC. YES!

image007.jpg
  1. swapped the memory cards of CR1000.

image008.jpg
  1. download Phenocam images. Yes!
  2. checked the fans of air temp. and relative humidity sensors on the tower and the floor. YES!
  3. Checked rain gage, make sure not clogged. YES!
  4. Downloaded met data from PC

image009.jpg

image010.jpg
  1. Checked CO2 profile:

The CO2 profile system wasn’t calibrated on site due to failure of IRGA. Turn off co2profile, take home IRGA.
10. closed gate and set up fence. YES!
Toniz_Floor Site
  1. Fence and gate power: 12 v.
  2. Swapped Li-7500s. Floor, sn 0041 on, sn 0042 off
  3. downloaded Winflux data from PC. YES!

image011.jpg
  1. Swapped the memory cards of CR1000.

image012.jpg
  1. downloaded met data from PC. YES!

CR23X3 – floor-Met
CR23X6 – tower-Met
CR10X2 – floor-Met
Soil CO2 profile: CR23X5 – soil CO2 profile

image013.jpg

image014.jpg

image015.jpg

image016.jpg
  1. Closed gate and set up fence. YES!

Field Data

No tank data

Well Depth

DateLocationDepth (feet)
2014-12-23TZ_floor32
2014-12-23TZ_road38.8
2014-12-23TZ_tower36.7

mode = both
Moisture Point Probes TZ
Array ( [0] => Tower [1] => Floor_South [2] => Floor_East [3] => Floor_West [4] => SoilCO2 [5] => Soil_Transect_4 [6] => Soil_Transect_3 [7] => Soil_Transect_2 [8] => Soil_Transect_1 [9] => SoilCO2_West_A [10] => SoilCO2_West_B [11] => SoilCO2_West_C )

Date DOY Rep Depth
Tower
Floor_South
Floor_East
Floor_West
SoilCO2
Soil_Transect_4
Soil_Transect_3
Soil_Transect_2
Soil_Transect_1
SoilCO2_West_A
SoilCO2_West_B
SoilCO2_West_C
Avg
Spacial Count
Measurement Count
2014-12-23 357 0 0-15cm 41.4 26.7 47.5 38.2 35.5 27 22.9 24.1 25 30.2 22.9 32
2014-12-23 357 0 15-30cm 35.3 55.5 37.4 38.7 33.2 37.8 35.3 35.9 29.8 29.8 27.1 36.5
2014-12-23 357 0 30-45cm 39.6 57.1 38 42.7 39.9 35.4 40.7 35.2 38.5 38.2 36.8 44.9
2014-12-23 357 0 45-60cm 41.4 42.8 61.5 61.7 43.1 35.4 40.8 47.1 40 44 51.1 45.7
2014-12-23 357 1 0-15cm 41.7
2014-12-23 357 1 15-30cm 35.9
2014-12-23 357 1 30-45cm 39.9
2014-12-23 357 1 45-60cm 41.4
2014-12-23 357 Avg 0-15cm 41.55 26.7 47.5 38.2 35.5 27 22.9 24.1 25 30.2 22.9 32 31.13 12 13
2014-12-23 357 Avg 15-30cm 35.6 55.5 37.4 38.7 33.2 37.8 35.3 35.9 29.8 29.8 27.1 36.5 36.05 12 13
2014-12-23 357 Avg 30-45cm 39.75 57.1 38 42.7 39.9 35.4 40.7 35.2 38.5 38.2 36.8 44.9 40.6 12 13
2014-12-23 357 Avg 45-60cm 41.4 42.8 61.5 61.7 43.1 35.4 40.8 47.1 40 44 51.1 45.7 46.22 12 13

mode = both
Moisture Point Probes VR
Array ( [0] => Solar_Panels [1] => Flux_Tower [2] => Gate [3] => Biomass_Cage )

Date DOY Rep Depth
Solar_Panels
Flux_Tower
Gate
Biomass_Cage
Avg
Spacial Count
Measurement Count
2014-12-23 357 0 0-15cm 28.2 22.9 21.4 8.3
2014-12-23 357 0 15-30cm 32.3 28.3 24 30.4
2014-12-23 357 0 30-45cm 32.1 20.4 27.4 41
2014-12-23 357 0 45-60cm 44.3 27.6 23.6 33.1
2014-12-23 357 1 0-15cm 27.9 24.1 21.2 8
2014-12-23 357 1 15-30cm 32.3 28.6 24 23.7
2014-12-23 357 1 30-45cm 32.7 20.4 27.1 32.4
2014-12-23 357 1 45-60cm 44 31.4 24.2 33.1
2014-12-23 357 Avg 0-15cm 28.05 23.5 21.3 8.15 20.25 4 8
2014-12-23 357 Avg 15-30cm 32.3 28.45 24 27.05 27.95 4 8
2014-12-23 357 Avg 30-45cm 32.4 20.4 27.25 36.7 29.19 4 8
2014-12-23 357 Avg 45-60cm 44.15 29.5 23.9 33.1 32.66 4 8

No TZ grass heigth found

No VR grass heigth found

Tree DBH

DateTag#Reading (mm)
2014-12-2310210.0
2014-12-23213.0
2014-12-2324520.1
2014-12-23313.0
2014-12-2349.2
2014-12-23512.9
2014-12-23710.0
2014-12-237219.5
2014-12-237915.3
2014-12-23813.8

No water potential data found

No TZ Grass Biomass data found

No TZ OakLeaves Biomass data found

No TZ PineNeedles Biomass data found

0 photos found

Graphs display:
16 sets found

No data found for TZ_Fenergy.
11 TZ_tmet graphs found

Tonzi Tower Met: Temperature and Power

Tonzi Tower Met: Solar Radiation

Tonzi Tower Met: IRT Sensors

LED Sensor Incoming

LED Sensor Outgoing

4-Band Solar Radiation

Air Temperature Profile

Relativity Humidity Profile

Tonzi Tower PRI

SRS PRI/NDVI

SRS NDVI

11 TZ_soilco2 graphs found

Tonzi Soil CO2 Profile: Open (East) CO2

Tonzi Soil CO2 Profile: Tree (West) CO2

Tonzi Soil CO2 Profile: Open (East) Temperatures

Tonzi Soil CO2 Profile: Tree (West) Temperatures

Tonzi Soil CO2 Profile: Upper CO2

Tonzi Soil CO2 Profile: Lower CO2

Tonzi Soil CO2 Profile: Upper Temperatures

Tonzi Soil CO2 Profile: Lower Temperatures

Tonzi Soil CO2 Profile: Power and Temperature

Tree 2 Soil CO2

Tree 2 Soil Temperature

Can't check TZ_mixed
3 TZ_mixed graphs found

Tonzi PPT

Tonzi CO2 and H2O Densities

Air Pressure

1 TZ_fflux graphs found

Tonzi Wind Speed

8 TZ_fmet graphs found

Soil Heat Flux

Tonzi Soil Temperature Set A

Tonzi Soil Temperatures Set B

Tonzi Soil Temperatures Set C

Tonzi Soil Temperature Set D

Well Level

Well Water Temperature

Soil Water Potential

1 TZ_tram graphs found

Tonzi Tram Incoming PAR

3 TZ_co2prof graphs found

Tower CO2 Profile Concentrations

Tower CO2 Profile Cell Pressure

CO2 Profile Sensor Temperature

No data found for TZ_irt.
No data found for TZ_windprof.
1 TZ_tflux graphs found

Tower CO2 and H2O

2 TZ_sm graphs found

Floor Solar Radiations

TZ Soil Moisture

Can't check TZ_met
1 TZ_met graphs found

Floor and Tower RH

Can't check TZVR_mixed
8 TZ_osu graphs found

Soil Moisture And Rain

SP1 Solar Radiation

SP1 Soil Temperature Profile

SP1 Soil Heat Flux

SP2 Soil Moisture

SP2 Soil Temperature

SP3 Soil Moisture

SP3 Soil Temperature

No data found for TZ_fd.
Tonzi Z-cam data

plot of Tonzi z-cam LAI

plot of Tonzi z-cam gap fration

 
 

Login
Select Notes:

This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.