Equipment and Calibration

View History

Equipment Entry

Instrument:Net Radiometer
Manufacture:Hukseflux
Model No:NR01
Serial No:1720
Tag No:
Acquisition Date:2013-03-13
Project:DOE-TCP
Location on 2017-01-26:Mayberry,
Notes: Initial factory calibration: Pyranometer Up (mn SR01 sn 2540) 13.71uV/Wm-2, Pyranometer Down (mn SR01 sn 2541) 13.36uV/Wm-2, Pyrgeometer Up (mn IR01 sn 2533) 10.30uV/Wm-2. Pyrgeometer Down (mn IR01 sn 2534) 10.84uV/Wm-2

Documents

Other: RadiometerTestReport_20130711.pdf
Report: 4-way Radiometer Comparison 10-2016 - 2017-04-07

History

Rec No.DateLoc FromTitleLoc ToNotes
2598 2017-01-26 Lab none Installed Mayberry Net Radiometer 4-way Installed on the Mayberry tower on the boom over the tules. This radiometer still has some marks on the SW domes, which may be cleanable.
2521 2016-11-02 Vaira Removed Lab none Removed from Vaira with the radiometer inter-comparison system that was on a stand alone tripod.
2508 2016-10-20 Twitchell Rice Moved Vaira Moved with radiometer test tripod from Twitchell Rice to Vaira Ranch to compare against Ione sensors.
2480 2016-10-06 Lab none Installed Twitchell Rice Installed in the Golden Radiometer experiment at Twtichell Rice.
1802 2015-04-29 Tonzi-Tower Removed Lab none Removed from the Tonzi Tower due to SWin spikes and dawn spikes in all channels. Replaced by CNR1 sn 020476. There are scratches on both SW domes from contact with the tower structure.
984 2013-04-10 Lab none Installed Tonzi-Tower This sensor was installed on the radiation boom at the top of the tower. It is next to the existing NR-lite and wired to the AM16/32 on the CR23X6