Ameriflux Site Info

Last field site visit:

2024-04-16 12:20:00 Tall alfalfa, pulled weeds, swapped 7500 for calibration, standard data.

Equipment installed at the site:
Arable Weather Station Mark 3
Arable Weather Station Mark II
Campbell Sci. Multiplexer AM16/32B
Campbell Sci. Multiplexer AM25T
Campbell Sci. Data Logger CR1000
Campbell Sci. Data Logger CR23X
Campbell Sci. Soil Moisture Probe CS655
Campbell Sci. Interface NL115
Decagon-METER Narrow Band SRS-Ni NDVI
Decagon-METER Narrow Band SRS-Pr PRI
Delta-T Soil Moisture Probe ML3
Fabricated Battery Bank BB-Fab
Forerunner-Eosense Forced Diffusion eosFD
Gill Anemometer WM 1590
Hukseflux Heat Flux Plate HFP01
Hukseflux Net Radiometer NR01
Kipp & Zonen Net Radiometer NR-LITE
Kipp & Zonen PAR Sensor PAR-LITE
Kipp & Zonen PAR Sensor PQS 1
LCJ Capteurs Anemometer SONIC-ANEMO-SPE10
Licor Gas Analyzer LI-7500A
StarDot Camera SD500BN-NL
TE Technology Heat Flux Plate HP-127-1.0-1.3-71P
Texas Electronics Precipitation TE525MM
Vaisala RH & Temp HMP155

Data Streams:

CodeDescription
BA_met Micromet data from the Bouldin Alfalfa site recorded by a CR1000 as 30min averages of 10sec samples.
BA_flux 30min averages of high frequency flux data from Licor GHG files
BA_cam Digital number data from Pheoncamera at Bouldin Alfalfa
BA_arable Hourly met data from an Arable Mark device. Raw times are in UTC, hourly averages with the time at the beginning of the averaging period beginning 20190401 changed to 30min data PST at end of averaging period. - stored in PST at end of averaging period.
BA_fd Soil respiration data at BA from the second generation Forced Diffusion chamber from Eosense. The raw data is collected at 5min intervals and averaged to 30min values. The chamber is located under the tower. Alfalfa was removed from inside the chamber.
BA_processed Fluxes and derived values from Level 1 processing
BA_processed3 Gap filling and partitioned data from Level 3 processing
BA_fdb Soil CO2 flux from an Eosense Forced Diffusion Chamber, 2nd chamber added under BA tower
BA_irtsr Surface temperature from two Apogee IRT sensors one pointing north and the other south at a 45 deg inclination. These are recorded at both 2Hz and 30min averages for surface renewal by Kevin Tu.
BA_edgeli75 Upper sonic and CO2/H2O data from BA Edge tower
BA_bncrli75 Upper sonic and CO2/H2O data from BA Bouncer tower
BA_bncr23x 30-min averages of met data from BA Bouncer CR23X
BA_edgecr6 Lower sonic at BA Edge tower
BA_bncrcr6 Lower sonic at BA Bouncer tower
BA_edge23x 30-min averages of met data from BA Edge CR23X
BA_adexcr1k 30-minute averages of data from CR1000 on the main BA tower measuring the upper and lower sonics
BA_adextrh 30-minute averages of temperature and RH data from the main BA met CR1000
BA_edgetrh 30min averages from 10sec lower and upper T/RH readings at BA Edge tower
BA_bncrtrh 30min averages from 10sec lower and upper T/RH readings at BA Bouncer tower
BA_sentek Soil data from the 1m long Sentek probe connected to the Arable. Original data is hourly average with UTC timestamp at the beginning of the averaging period. The times have been adjusted back 7.5 hours to the middle of the averaging period in local standard time and linearly interpolated to 30min intervals.

         
 
 
 
  This material is based upon work supported by the National Science Foundation and US Department of Energy. Any opinions, findings, conclusions, or recommendations expressed in the material are those of the author(s) and do not necessarily reflect the views of the supporters.