Field Notes
<--2012-09-06 13:00:00 | 2012-09-20 13:00:00-->Other sites visited today: Sherman Island | Mayberry | Twitchell Rice | DWR Corn
Phenocam link: Searching...
West Pond: 2012-09-13 13:20:00 (DOY 257)
Author: Cove Sturtevant
Others: Sara, Laurie
Summary: tower readings good, Vaisala RH about 6 percentage points low compared to standard, will double check next time
West Pond
2012-09-13 We arrived at about 13:20 PDT. Hot, with some thin high altitude clouds. I checked the tower readings while Sara and Laurie went off to collect water samples. I swapped the USB stick (testing new white Lexar stick) in the 7550 box and downloaded the MET data and autocam pics. Current 7500 readings: CO2 = 380 ppm H2O = 650 mmol m-3 agc = 50 (reduced to 43.8 after cleaning) t = 31.12 C 7700 readings: CH4 = 2.1 ppm RSSI = 47 (bumped to 74 after cleaning) DO readings looked good, other MET values looked fine. I checked the tower Vaisala against the standard (again not realizing to keep the standard out of the sun before putting it into the shield to reduce the settling time). The standard read intermediate to the tower Vaisala temperature before and after, but the tower RH seemed a little high (but I’ll double check next time). Standard: T = 32.5 C; RH =28% Tower probe: T = 31.6 C before, 33.0 C after; RH = 33.8% before, 34% after |
1 photos found
WP_autocam_20120913_0645.jpg ( 2012-09-13 06:45:02 ) Full size: 1920x1440
Hawk skimming above tules
8 sets found
Can't check WP_DO
1 WP_DO graphs found
14 WP_met graphs found
5 WP_flux graphs found
Can't check MBWPEESWGT_mixed
Can't check MBEEWPSWEPGT_cam
Can't check MBSWEEWPBCBA
1 WP_processed graphs found
No data found for WP_arable.