Field Notes

<--2024-05-01 14:45:00 | 2024-05-22 14:05:00-->
Other sites visited today: Bouldin Corn | Bouldin Alfalfa

Hill Slough: 2024-05-16 08:15:00 (DOY 137)
Author: Daphne Szutu
Others: Dennis

Summary: Windy, shadowband missing, installed sonic rangefinder at channel, installed CTD at channel to replace one that was removed previously

2024-05-16
Hill Slough

Dennis and I arrived at 8:15 PST (9:15 PDT). The green wedge of tules/cattails on the west side of Highway 12 seems to have grown more to the south. It was mild and sunny and
SO windy. It was near high tide and the staff gauge read 5.5 ft at 8:39 PST.

Dennis was listening to a dean’s meeting on his phone, so I got started with the regular tower servicing.

I downloaded met, cam, and USB GHG data. The shadowband for dfPAR was missing—probably blown away and never to be found. I changed the 7700 heater from winter to summer hours. Previously, the heater turned on from 18:00 to 09:00, now the heater will turn on from 20:00 to 06:00. I topped off the wash reservoir and cleaned flux and rad sensors.

I measured the porewater and surface water conductivity.

Sample, Temperature-compensated conductivity, Temperature
Surface, 2024uS, 17.1C
Porewater, 5.57mS, 17.4C

At the channel, I installed a new sonic rangefinder sn 76294 in the CR23X (5V power, SE data). I screwed the rangefinder to the bottom of the boardwalk near the EXO and miniDOT. We are hoping this will give us backup water level data when the other sensors are out of the water.

I also installed HYDROS21 CTD sn H21G20001202 on the CR23X, which has a shorter cable after being chewed at GT. I couldn’t remember what the SDI-12 address was (tried both 0 and 2), so I wired it briefly to the tower CR1000 to use LoggerNet’s Terminal Emulator. I changed the SDI-12 address from 6 to 0. The Teflon filter for the atmospheric pressure vent had to be cut off, so it needs additional
desiccant like the Campbell water level sensors. I had a tube of dry desiccant, but forgot to put it on. Next time.

I updated the channel CR23X program to add in the sonic rangefinder (the CTD was already in the program). I also updated the tower CR1000 program to add in a new data column for the sonic rangefinder. I will need to make a new stream field version next time I upload HS met data.

The 7500 read: 414ppm CO2, 579 mmol/m3 H2O, 16.5C, 101.6kPa, 98SS -- 98 after cleaning
The 7700 read: 1.97ppm CH4, 45RSSI – 77 after cleaning

We left at 9:45 PST (10:45 PDT).

0 photos found

Graphs display:
4 sets found

20 HS_met graphs found

Explore the graph:Temperatures in a new window

Explore the graph:Temperature Profile A in a new window

Explore the graph:Temperature Profile B in a new window

Explore the graph:Temperature Profile C in a new window

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Four-channel radiometer in a new window

Explore the graph:NDVI Channels in a new window

Explore the graph:PAR in a new window

Explore the graph:Air Pressure in a new window

Explore the graph:Air T and RH in a new window

Explore the graph:pCO2 in a new window

Explore the graph:Soil Moisture in a new window

Explore the graph:Battery Voltage in a new window

Explore the graph:Forced Diffusion Soil CO2 Flux in a new window

Explore the graph:Dissolved Oxygen in a new window

Explore the graph:Water Level in a new window

Explore the graph:Conductivity in a new window

Explore the graph:EXO pH + ORP in a new window

Explore the graph:EXO Turbidity + fDOM in a new window

Explore the graph:Water Temp in a new window

4 HS_flux graphs found

Explore the graph:CO2 and H2O in a new window

Explore the graph:Wind in a new window

Explore the graph:Methane in a new window

Explore the graph:Data Counts in a new window

1 HS_cam graphs found

Explore the graph:GCC in a new window

Can't check HS_Processed
2 HS_Processed graphs found

Explore the graph:Energy in a new window

Explore the graph:CO2, CH4 Net Fluxes in a new window