Field Notes

<--2022-05-10 10:30:00 | 2022-06-07 10:40:00-->
Other sites visited today: Tonzi | West Pond | East End

Vaira: 2022-05-26 10:30:00 (DOY 146)
Author: Joe Verfaillie
Others: Carlos

Summary: Hot and dry, Carlos's first visit - watch out from them foxtails! Installed three SoilVUE soil moisture profile probes, power seems okay, went to the pond.

Vaira
2022-05-26

Carlos and I arrived at about 10:30 PDT. It was warm and sunny and dry with just a few high thin clouds. It looked like the wind was blowing hard when we drove through Sacramento, but here just a nice breeze. The last three days have been really hot. The grasses are mostly yellow and crispy.

We measured the well level together and then installed three new SoilVUE10 soil moisture profile sensors provided by the Ameriflux year of water. These sensors provide six readings at -5, -10, -20, -30, -40 and -50cm of soil moisture, temperature, electrical conductivity and permittivity. To install we had to dig 60cm deep holes with a standard 5 cm (2-inch) hand auger. This proved difficult as we hit hard material three times and had to find a new spot to try. Moving over just 40cm could make the difference. Once you had a hole you wetted the sides with water and then screwed in the sensor. The sensors use SDI-12 as each provides 24 columns of data. I added a slow sequence to the existing CR1000 met program to sample these probes every 10min using a concurrent (C!) SDI-12 command. It’s possible that using the measure command (M!) might be better but an M! has to be issued for each depth so six per probe. The probes installed were:
B: sn 2690 5.4m at heading 345deg about halfway between the eddy tower and radiation tower
C: sn 2679 7.7m at heading 26deg near the solar panels and the old Moisture Point probe
A: sn 2677 5.3m at heading 220deg about a meter outside the fence near the gate.
I saw readings from the first two after we returned from the pond but not for 2677

I downloaded the flux, met, camera and FD data. Still having serial port problems even with new USB adapter. I didn’t see any dropped data this time so the power issues seem to have been fixed for now. I lost the screen shot of the 7500 numbers when the laptop restarted due to the serial port.

We went to the pond. The stream is still running well but the pond is going down. I did not see any cows and left the fence power off.

Carlos did spectra while I made a last check on the new probes on the way out.

We left at about 13:20

Field Data

No tank data

Well Depth

DateLocationDepth (feet)
2022-05-26WP2.67
2022-05-26VR_pond16.3
2022-05-26VR_well55.3
2022-05-26TZ_floor25.2
2022-05-26TZ_road34.25
2022-05-26TZ_tower29.1

mode = both
Moisture Point Probes TZ
Array ( [0] => Tower [1] => Soil_Transect_4 [2] => Soil_Transect_3 [3] => Soil_Transect_2 [4] => Soil_Transect_1 [5] => SoilCO2_West_A [6] => SoilCO2_West_C )

Date DOY Rep Depth
Tower
Soil_Transect_4
Soil_Transect_3
Soil_Transect_2
Soil_Transect_1
SoilCO2_West_A
SoilCO2_West_C
Avg
Spacial Count
Measurement Count
2022-05-26 146 0 0-15cm 7.1 0.4 0.1 4.7 1.5 10.3 4.7
2022-05-26 146 0 15-30cm 12.4 6.3 14.2 12.7 4.8 9.3 12.4
2022-05-26 146 0 30-45cm 15.6 10.3 13.1 17.3 13.7 15.4 12.3
2022-05-26 146 0 45-60cm 21.9 12.8 19.6 28.8 14.5 18.2 16.5
2022-05-26 146 1 0-15cm 6.5 0.4 0.1 4.2 1.8 10 4.7
2022-05-26 146 1 15-30cm 12.4 6.9 14.5 13 4.8 8.7 12.4
2022-05-26 146 1 30-45cm 15.6 10.6 14 17.3 14 16.2 12.6
2022-05-26 146 1 45-60cm 20.8 12.5 18.2 29.4 14.2 18.2 16.5
2022-05-26 146 2 0-15cm 1.2
2022-05-26 146 2 15-30cm 7.8
2022-05-26 146 2 30-45cm 10.9
2022-05-26 146 2 45-60cm 12.5
2022-05-26 146 Avg 0-15cm 6.8 0.67 0.1 4.45 1.65 10.15 4.7 4.07 7 15
2022-05-26 146 Avg 15-30cm 12.4 7 14.35 12.85 4.8 9 12.4 10.4 7 15
2022-05-26 146 Avg 30-45cm 15.6 10.6 13.55 17.3 13.85 15.8 12.45 14.16 7 15
2022-05-26 146 Avg 45-60cm 21.35 12.6 18.9 29.1 14.35 18.2 16.5 18.71 7 15

No VR Moisture Point data found

No TZ grass heigth found

No VR grass heigth found

No VR Tree DBH found

No water potential data found

No VR Grass Biomass data found

No VR OakLeaves Biomass data found

No VR PineNeedles Biomass data found

0 photos found

Graphs display:
9 sets found

16 VR_met graphs found

Explore the graph:Temperatures in a new window

Explore the graph:System Power Voltage in a new window

Explore the graph:Soil Temperatures Set 1 in a new window

Explore the graph:Soil Temperatures Set 2 in a new window

Explore the graph:Soil Temperature Set 3 in a new window

Explore the graph:Soil Temperature at -4cm in a new window

Explore the graph:Soil Heat Flux in a new window

Explore the graph:Soil Moisture in a new window

Explore the graph:Photosynthetic Active Radiation in a new window

Explore the graph:Short/Long Wave Radiation in a new window

Explore the graph:LED sensor in a new window

Explore the graph:Vaira PPT in a new window

Explore the graph:Peltier SHF Plates in a new window

Explore the graph:Peltier SHF Temperatures in a new window

Explore the graph:LED NDVI in a new window

Explore the graph:NDVI SRS Raw Data in a new window

2 VR_flux graphs found

Explore the graph:CO2 Density in a new window

Explore the graph:Sonic Wind in a new window

0 VR_soilco2 graphs found

2 VR_pond graphs found

Explore the graph:Pond Level and Rain in a new window

Explore the graph:Vaira Pond Temperatures in a new window

Can't check TZVR_mixed
3 VR_fd graphs found

Explore the graph:Varia Forced Diffusion Soil CO2 Flux in a new window

Explore the graph:Vaira Forced Diffusion CO2 Concentration in a new window

Explore the graph:VR Forced Diffusion Temperature in a new window

4 VR_processed graphs found

Explore the graph:VR VPD in a new window

Explore the graph:NEE in a new window

Explore the graph:Soil Water Content in a new window

Explore the graph:Gap Filled GPP in a new window

4 VR_arable graphs found

Explore the graph:Incoming bands in a new window

Explore the graph:Reflected Bands in a new window

Explore the graph:Solar Radiation in a new window

Explore the graph:Pressure and RH in a new window

No data found for VR_soilvue.