Field Notes
<--2021-10-06 12:35:00 | 2021-11-17 12:20:00-->Other sites visited today: Hill Slough | Vaira
Phenocam link: Searching...
Tonzi: 2021-10-26 12:00:00 (DOY 299)
Author: Joe Verfaillie
Others:
Summary: Floor HMP45 fell on the ground - replaced but needs new fan, soil wet all the way down, Tree 1 FD performance check, replace CR1000 IRT SLA battery, retested tipping buckets, swapped road well power pack
Tonzi 2021-10-26 I arrived at about 12:00 noon PDT. I met Rob on the way in – he said his mail is getting vandalized and he has a new PO Box. It was mostly overcast and cool but when the sun did break through it was almost hot. Record breaking rains a couple days ago. The pond is now about 2/3 full. The ground is thoroughly wet but not soggy yet. There are large puddles in the road. The trees look greener – mostly because the storm knocked all the brown leaves off. There are quite a few broad leaf sprouts coming up but little grass and not enough to add a tinge of green yet. All seemed well. I collected the flux, met, phenocam, z-cam, DBH, well levels, soil moisture and FD data. The Tower 7500: 415.5ppm CO2, 469.5mmol/m3 H2O, 99.8kPa, 16.3C, 102.6SS The Floor 7500: 413.5ppm CO2, 501.3mmol/m3 H2O, 99.9kPa, 17.1C, 100.7SS The storm washed everything clean. The Floor HMP45 had fallen out of its solar shield and was laying on the ground. I put in back in place but the fan was dead and I didn’t have a spar (forgot the blue bag). Need to swap the fan next time. The soil was saturated all the way down to 60cm. The well levels have stayed steady or fallen a bit still so all the water has been soaked up by the surface. Resetting the CO2 concentration on the Open FD chamber seemed to work last time. I did another performance check on the Tree1 FD chamber and it acknowledged that I reset its CO2 concentration but it was a bit hard to tell. The flux data looks okay though. I replaced the SLA battery on the IRT CR1000 that has been failing. I retested the two tipping buckets that were slightly off last time. SP2 got 50/50 tips and the Main bucket got 49/50 tips. The adjustments last time were good and the data is correct for the most recent rain. The power pack on the road well was dead. I swapped it with the one I was using for the tipping bucket test pump. I left for Vaira at about 15:00 PDT |
Field Data
No tank data
Well Depth
Date | Location | Depth (feet) |
---|---|---|
2021-10-26 | TZ_floor | 32.4 |
2021-10-26 | TZ_road | 40 |
2021-10-26 | TZ_tower | 37.2 |
2021-10-26 | VR_well | 60.5 |
2021-10-26 | VR_pond | 22.28 |
2021-10-26 | HS | 5.29 |
mode = both
Moisture Point Probes TZ
Array
(
[0] => Tower_1
[1] => Soil_Transect_3_1
[2] => Soil_Transect_2_1
[3] => Soil_Transect_1_1
[4] => SoilCO2_West_A_1
[5] => SoilCO2_West_B_1
[6] => SoilCO2_West_C_1
[7] => Tower_2
[8] => Soil_Transect_4_2
[9] => Soil_Transect_3_2
[10] => Soil_Transect_2_2
[11] => Soil_Transect_1_2
[12] => SoilCO2_West_A_2
[13] => SoilCO2_West_B_2
[14] => SoilCO2_West_C_2
[15] => Tower_3
[16] => Soil_Transect_4_3
[17] => Soil_Transect_3_3
[18] => Soil_Transect_2_3
[19] => Soil_Transect_1_3
[20] => SoilCO2_West_A_3
[21] => SoilCO2_West_B_3
[22] => SoilCO2_West_C_3
[23] => Tower_4
[24] => Soil_Transect_4_4
[25] => Soil_Transect_3_4
[26] => Soil_Transect_2_4
[27] => Soil_Transect_1_4
[28] => SoilCO2_West_A_4
[29] => SoilCO2_West_B_4
[30] => SoilCO2_West_C_4
[31] => Soil_Transect_4_1
)
Date | DOY | Rep | Depth | Tower_1 |
Soil_Transect_3_1 |
Soil_Transect_2_1 |
Soil_Transect_1_1 |
SoilCO2_West_A_1 |
SoilCO2_West_B_1 |
SoilCO2_West_C_1 |
Tower_2 |
Soil_Transect_4_2 |
Soil_Transect_3_2 |
Soil_Transect_2_2 |
Soil_Transect_1_2 |
SoilCO2_West_A_2 |
SoilCO2_West_B_2 |
SoilCO2_West_C_2 |
Tower_3 |
Soil_Transect_4_3 |
Soil_Transect_3_3 |
Soil_Transect_2_3 |
Soil_Transect_1_3 |
SoilCO2_West_A_3 |
SoilCO2_West_B_3 |
SoilCO2_West_C_3 |
Tower_4 |
Soil_Transect_4_4 |
Soil_Transect_3_4 |
Soil_Transect_2_4 |
Soil_Transect_1_4 |
SoilCO2_West_A_4 |
SoilCO2_West_B_4 |
SoilCO2_West_C_4 |
Soil_Transect_4_1 |
Avg | Spacial Count |
Measurement Count |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2021-10-26 | 299 | 0 | nan | 46.4 | 24.7 | 29.9 | 21.4 | 43.4 | 36.7 | 36.1 | 35 | 43.3 | 35.9 | 34.7 | 32.6 | 31.3 | 46.3 | 32.9 | 31.8 | 39.1 | 32.7 | 31.8 | 36.3 | 35.2 | 38 | 36.8 | 40 | 34.9 | 46 | 48.6 | 39.4 | 44 | 49.4 | 46.6 | ||||
2021-10-26 | 299 | 1 | nan | 46.1 | 24.1 | 29.4 | 21.7 | 43.7 | 37.3 | 35.8 | 35.6 | 43.3 | 35 | 34.7 | 32.6 | 31.6 | 46.9 | 34.4 | 31.5 | 39.1 | 32.4 | 32.4 | 36.8 | 35.4 | 36 | 36.3 | 42.3 | 35.4 | 45.1 | 48.3 | 39.7 | 44.3 | 48.3 | 48.8 | 20 | |||
2021-10-26 | 299 | Avg | 0-15cm | 0 | 0 | |||||||||||||||||||||||||||||||||
2021-10-26 | 299 | Avg | 15-30cm | 0 | 0 | |||||||||||||||||||||||||||||||||
2021-10-26 | 299 | Avg | 30-45cm | 0 | 0 | |||||||||||||||||||||||||||||||||
2021-10-26 | 299 | Avg | 45-60cm | 0 | 0 |
No VR Moisture Point data found
No TZ grass heigth found
No VR grass heigth found
Tree DBH
Date | Tag# | Reading (mm) |
---|---|---|
2021-10-26 | 1 | 15.1 |
2021-10-26 | 102 | 14.0 |
2021-10-26 | 2 | 13.5 |
2021-10-26 | 245 | 4.2 |
2021-10-26 | 3 | 19.0 |
2021-10-26 | 4 | 14.0 |
2021-10-26 | 5 | 8.4 |
2021-10-26 | 6 | 19.6 |
2021-10-26 | 7 | 7.7 |
2021-10-26 | 72 | 11.9 |
2021-10-26 | 79 | 12.3 |
No water potential data found
No TZ Grass Biomass data found
No TZ OakLeaves Biomass data found
No TZ PineNeedles Biomass data found
0 photos found
16 sets found
No data found for TZ_Fenergy.
11 TZ_tmet graphs found
11 TZ_soilco2 graphs found
Can't check TZ_mixed
3 TZ_mixed graphs found
1 TZ_fflux graphs found
8 TZ_fmet graphs found
No data found for TZ_tram.
3 TZ_co2prof graphs found
1 TZ_irt graphs found
No data found for TZ_windprof.
1 TZ_tflux graphs found
2 TZ_sm graphs found
Can't check TZ_met
1 TZ_met graphs found
Can't check TZVR_mixed
8 TZ_osu graphs found
3 TZ_fd graphs found
Tonzi Z-cam data